Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Part 21 Report - 1997-781

ACCESSION #: 9710150086 Coltec Industries Fairbanks Morse Engine Division 701 White Avenue Beloit, WI 53511-5492 608/364-4411 FAX: 608/364-0382 INTERIM LETTER * Addenda: 1, dated 08 OCT 97 * To: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC. 20555 From: Coltec Industries-Fairbanks Morse Engine Division (FMED) Date: 30 September 1997 (original issue date) Subject: Weldments on Opposed Piston and Coltec-Pielstick Emergency Stand-By Diesel Gen-Set Lube-Oil and Jacket Water Piping Systems Upon further investigation, the list of potentially affected unites is revised to include the asterisked (*) utilities. Arkansas Nuclear One Millstone 1 & 2 Calvert Cliffs 1 & 2 North Anna 1 & 2 Crystal River 3 Peach Bottom 2 & 3 Duane Arnold Energy Center Plant Hatch 1 & 2 Farley 1 & 2 Prairie Island 1 & 2 Fermi 2 & 3 Three Mile Island 2 & 3 * H. B. Robinson 3 Vermont Yankee Sincerely, Scott A. Fratianne Sr. Quality Assurance Engineer A division of Coltec Industries Inc. *** END OF DOCUMENT ***