Skip to main content

Part 21 Report - 1997-550

ACCESSION #: 9708140155 Information & Support Services P.O. Box 3707 Seattle, WA 98124-2207 BOEING August 7, 1997 G-1151-SJA-97-376 Document Control Desk United States Nuclear Regulatory Commission Washington, D.C. 20555 Reference: a) Boeing Letter G-1151-RSO-92-365 dated August 31, 1992; R. S. Orr to the NRC Operations Center b) NRC Letter Docket No. 99901227 dated August 12, 1992; L. J. Norrholm to R. S. Orr; Subject: Response to 10 CFR 21 Inquiry Dear Sir or Madam: In accordance with the reference correspondence and 10 CFR 21, Boeing is sending the NRC the attached error notice(s) received from our former software suppliers. Because of unknown current addresses, the following former customers were not notified; Reactor Controls, Inc. Echo Energy Consultants, Inc. Nuclear Applications and Systems Analysis Company (Japan) Nuclear Power Services Error notices have been sent to our other former customers. Very truly yours, Sandra J. Andrews Nuclear Administrator Phone: (206) 865-6248 FAX: (206) 865-4851 Mail Stop: 7A-33, or e-mail: Sandra.Andrews@PSS.Boeing.com Enclosure(s): GTSTRUDL Program Report Forms 97.05 and 97.06 Georgia Institute of Technology GT STRUDL [Registered Trademark] August 1, 1997 Attention: Nuclear Administrator Boeing information & Support Services P.O. Box 24346, M/S 7A-33 Seattle, Washington 98124-0346 RE: GT STRUDL Dear Sir or Madam: Enclosed please find copies of GTSTRUDL PROGRAM REPORT FORMS 97.05 and 97.06 and a GTSTRUDL QA CUSTOMER ACKNOWLEDGEMENT FORM. Please sign and return the GTSTRUDL QA CUSTOMER ACKNOWLEDGEMENT FORM to acknowledge receipt of the GTSTRUDL Program Report. Thank you for reviewing the Program Report and for returning the Acknowledgement Form. Best regards, CASE Center David C. Key Configuration Control Manager Enclosures Computer Aided Structural Engineering Center Phone: (404) 894-2260 School of Civil & Environmental Engineering Fax: (404) 894-8014 Atlanta, Georgia 30332-0355 USA casec@ce.gatech.edu A Unit of the University System of Georgia GTSTRUDL Program Report Form GPRF No.: DATE: FROM: Computer-Aided Structural Engineering Center Georgia Institute of Technology Atlanta, Georgia 30332-0355 SEVERITY LEVEL: __ URGENT Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job. __ SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task. __ MINOR Problem can be worked around or problem poses high frustration factor. __ INFORMATIVE Documentation error, program usage tip, user inconveniences. Date Problem Confirmed Date Notification Sent Computers Operating System Version Target Release for Correction Signature Title R & D Division Typed or Printed Name Date of Signature Signature Title Professional Services Division Typed or Printed Name Date of Signature Rev 2.2 GTSTRUDL Program Report Form (continued) GPRF No.: DATE: DESCRIPTION: If the first two incidences in an element definition are the same, GTMenu will abort in CHECK ALL. As a work-around, CHECK ELEMENT GEOMETRY notes that the minimum incidence angle is 0 degrees (under Aspect Ratio). Relevant documentation: GTMenu CHECK - USER MANUAL, Volume 6, Chapter 14 Rev 2.2 GTSTRUDL Program Report Form GPRF No.: DATE: FROM: Computer-Aided Structural Engineering Center Georgia Institute of Technology Atlanta, Georgia 30332-0355 SEVERITY LEVEL: -- URGENT Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job. __ SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task. X MINOR Problem can be worked around or problem poses high frustration factor. __ INFORMATIVE Documentation error, program usage tip, user inconveniences. Date Problem Confirmed August 1, 1997 Date Notification Sent Computers PC Operating System DOS, Windows NT, Windows 95 Version 97.01 Target Release for Correction 97.02 Signature Title R & D Division Typed or Printed Name Date of Signature Signature Title Professional Services Division Typed or Printed Name Date of Signature Rev. 2.2 GTSTRUDL Program Report Form (Continued) GPRF No.: DATE: DESCRIPTION: The following error message will be printed from the STIFFNESS ANALYSIS and CONSISTENCY CHECK commands when a loading condition has never been correctly created, but has been referenced in a command such as the LOAD LIST command: **** ERROR_STCHCK -- Load xxxxxxxx exists, but has no data. The loading name xxxxxxxx specified in the message does not refer to the correct loading condition. In most cases, xxxxxxxx will be an undecipherable string of characters. There is no work-around for this error. Pertinent Sections from the User's Manual STIFFNESS ANALYSIS command Section 2.1.13.2, Volume 1 CONSISTENCY CHECK command Section 2.1.12.4, Volume 1 Rev. 2.2 *** END OF DOCUMENT ***

Page Last Reviewed/Updated Wednesday, March 24, 2021

Page Last Reviewed/Updated Wednesday, March 24, 2021