Skip to main content

Part 21 Report - 1997-057

ACCESSION #: 9705140292 Information & Support Services P.O. Box 3707 Seattle, WA 98124-2207 May 6, 1997 G-1151-SJA-97-202 Document Control Desk United States Nuclear Regulatory Commission Washington, D.C. 20555 Reference: a) Boeing Letter G-1151-RSO-92-365 dated August 31, 1992; R. S. Orr to the NRC Operations Center b) NRC Letter Docket No. 999010227 dated August 12, 1992; L. J. Norrholm to R. S. Orr; Subject: Response to 10 CFR 21 Inquiry Dear Sir or Madam: In accordance with the reference correspondence and 10 CFR 21, Boeing is sending the NRC the attached error notice(s) received from our former software suppliers. Because of unknown current addresses, the following former customers were not notified: Reactor Controls, Inc. Echo Energy Consultants, Inc. Nuclear Applications and Systems Analysis Company (Japan) Nuclear Power Services Error notices have been sent to our other former customers. Very truly yours, Sandra J. Andrews Nuclear Administrator Phone: (206) 865-6248 FAX: (206) 865-4851 Mail Stop: 7A-33, or e-mail: Sandra.Andrews@PSS.Boeing.com Enclosure(s): Reissue of GTSTRUDL Program Report Form 97.03 Georgia Institute of Technology GTSTRUDL [Registered Copy] MAY 06 1997 April 29, 1997 CONTRACTS Attention: Nuclear Administrator Boeing Information & Support Services P.O. Box 24346, M/S 7A-33 Seattle, Washington 98124-0346 RE: GT STRUDL Dear Sir or Madam: It was recently brought to our attention that the April 14, 1997 mailing of GPRF 97.03 was sent out with an incorrect cover letter. In response, we are reissuing GPRF 97.03 in order to ensure proper reporting. As this mailing replaces the previous issue of GPRF 97.03. I request that you return the current Vendor Acknowledgment Form even if we have already received the Form from the previous mailing. I apologize for any inconvenience this may have caused, and thank you for your assistance in the handling of this matter. Best Regards, CASE Center David C. Key Configuration Control Manager c: Lawrence F. Kahn, Director Enclosures Computer Aided Structural Engineering Center Phone: (404) 894-2260 School of Civil & Environmental Engineering Fax: (404) 894-8014 Atlanta, Georgia 30332-0355 USA casec@cc.gatech.edu A Unit of the University System of Georgia Georgia Institute of Technology GTSTRUDL [Registered Copy] MAY 06 1997 April 29, 1997 CONTRACTS Attention: Nuclear Administrator Boeing Information & Support Services P.O. Box 24346, M/S 7A-33 Seattle. Washington 98124-0346 RE: GT STRUDL Dear Sir or Madam: Enclosed please rind copies of GTSTRUDL PROGRAM REPORT FORM No. 97.03 and a VENDOR ACKNOWLEDGMENT FORM. Please sign and return the VENDOR ACKNOWLEDGMENT FORM to acknowledge receipt of the GTSTRUDL Program Report. Thank you for reviewing the Program Report and for returning the Acknowledgment Form. Best regards, CASE Center Lawrence F. Kahn Director LFK/tlk Enclosures Computer Aided Structural Engineering Center Phone: (404) 894-2260 School of Civil & Environmental Engineering Fax: (404) 894-8014 Atlanta, Georgia 30332-0355 USA casec@cc.gatech.edu A Unit of the University System of Georgia GTSTRUDL Program Report Form GPRF No.: DATE: FROM: Computer-Aided Structural Engineering Center Georgia Institute of Technology Atlanta, Georgia 30332-0355 SEVERITY LEVEL: X URGENT Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job. _ SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task. _ MINOR Problem can be worked around or problem poses high frustration factor. _ INFORMATIVE Documentation error, program usage tip, user inconveniences. Date Problem Confirmed Date Notification Sent Computers All Operating System All Version 94.01 and later Target Release for Correction 97.01 NT Mgr. ASD Signature Title R & D Division Michael H. Swanger Typed or Printed Name Date of Signature Signature Title Professional Services Division Typed or Printed Name Date of Signature Rev 22 GTSTRUDL Program Report Form (Continued) GPRF No.: DATE: DESCRIPTION: Specifying elastic member end connection spring constant data in CHANGES mode may cause a subsequent STIFFNESS ANALYSIS to abort or produce incorrect results. Work around: Give the PRINT MEMBER RELEASES command following the MEMBER RELEASES command in CHANGES mode and prior to the STIFFNESS ANALYSIS command: CHANGES MEMBER RELEASES 1 TO 10 START ELASTIC KMZ 1000.0 ADDITIONS PRINT MEMBER RELEASES o o o STIFFNESS ANALYSIS Applicable sections of the User's Manual MEMBER RELEASES Command Section 2.1.8.2, Volume 1 Rev. 22 *** END OF DOCUMENT ***

Page Last Reviewed/Updated Wednesday, March 24, 2021

Page Last Reviewed/Updated Wednesday, March 24, 2021