Part 21 Report - 1997-020
LICENSEE: ABB-COMBUSTION ENGINEERING SITE: ABB-COMBUSTION ENGINEERING EN NUMBER:31616 DOCKET: EVENT DATE: 12-06-96 RX TYPE: EVENT TIME: 12:00 VENDORS: NOTIFY DATE: 01-17-97 EMERGENCY CLASS: N/A REGION: 1 STATE: CT TIME: 16:15 OPS OFFICER: DICK JOLLIFFE 10 CFR SECTION: CCCC 21.21 UNSPECIFIED PARAGRAPH - ABB-CE 10CFR21 REPORT ON PIPING PRESSURE LOSSES BETWEEN SG AND MSSVs - ON 12/06/96, ABB-COMBUSTION ENGINEERING IDENTIFIED A DEFECT CONCERNING THE PIPING PRESSURE LOSSES (i.e., DIFFERENTIAL PRESSURE) BETWEEN THE STEAM GENERATOR (SG) AND THE MAIN STEAM SAFETY VALVE (MSSV) INLETS WHEN THE MSSVs ARE ACTIVATED. OMISSION OF THE SUBJECT PRESSURE LOSS FROM ANALYSES OF OCCURRENCES DURING WHICH MSSVs ACTUATE COULD ADVERSELY AFFECT THE RESULTS OF CORRESPONDING LOCA AND NON-LOCA THERMAL HYDRAULIC SAFETY ANALYSES, MSSV PERFORMANCE, AND PIPING SYSTEM STRUCTURAL ANALYSES. THE MAGNITUDE OF THE PIPING PRESSURE LOSSES THAT ABB-CE HAS EXAMINED RANGES FROM APPROXIMATELY 10 PSI TO MORE THAN 50 PSI. ABB-CE DETERMINED THAT THIS OMISSION WAS APPLICABLE TO ALL SAFETY ANALYSES DURING WHICH THE MSSVs ARE ACTIVATED FOR NUCLEAR POWER PLANTS FOR WHICH ABB-CE WAS THE NUCLEAR STEAM SUPPLY SYSTEM (NSSS) SUPPLIER. ON 01/16/97, ABB-CE NOTIFIED EACH LICENSEE FOR WHICH IT WAS THE NSSS SUPPLIER OF THIS ISSUE. ABB-CE CONSIDERS THAT THIS ISSUE MAY BE APPLICABLE TO NUCLEAR POWER PLANTS OTHER THAN THOSE FOR WHICH ABB-CE WAS THE NSSS SUPPLIER.
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021