Part 21 Report - 1996-721

ACCESSION #: 9608090214 FAX Message TSI TSI Incorporated Environmental Measurements & Controls Division 1 800 777 8356 500 Cardigan Road Tel: 612 490 2711 Shoreview, MN 55126-3996 Fax 612 490 2874 Date: August 7, 1996 Organization: Nuclear Regulatory Commission Attn: Operations Center FAX: 301-816-5151 Tel: 301-816-5100 From: Richard Remiarz Re: 10 CFR Ch. (1-1-95 Edition) Section 21.21 (a)(1) Pages: 4 The attached documents are being faxed to the NRC Operations Center to meet the notification requirements of the above-referenced section. If you have any questions, please feel free to contact TSI Incorporated at 800-876-9874. Environmental Measurements 612 490 2888 and Controls Division Fax: 612 490 2874 500 Cardigan Road P.O. Box 64394 St. Paul, MN 55164 U.S.A. TSI YOUR IMMEDIATE ATTENTION REQUESTED Potential Problem Affecting Some Air Velocity Test Instruments August 7, 1996 Dear Quality Assurance Manager: This letter is being mailed to all NUPIC members. Acting in accordance with the requirements of MIL Standard 45662A, we are sending the attached letter to all identified owners of the following instruments within the next 30 days: VELOCICALC [Registered Trademark] Models 8355, 8357, 8360, 8382, 8383, 8388 VELOCICHECK [Registered Trademark] Models 8330, 8340 ACCUBALANCE [Registered Trademark] Model 8370 DP-CALC [Registered Trademark] Models 8702, 8704 If you have any questions, please contact me at 800-777-8356. Sincerely, Richard J. Remiarz, Business Unit Manager Industrial Test Instruments Group Environmental Measurements & Controls Division Environmental Measurements 612 490 2888 and Controls Division Fax: 612 490 2874 500 Cardigan Road P. O. Box 64394 St. Paul, MN 55164 U.S.A. TSI August 7, 1996 Attn: Quality Assurance Manager Calibration Laboratory Manager Dear Valued Customer, We have recently discovered a problem that can potentially affect the performance of some instruments under certain environmental conditions. Printed circuit board assemblies manufactured by one of our vendors have been found to be contaminated with a microscopic coating of residue. At times the residue can act as a conductor. causing current leakages that can affect the performance of the instrument. The effect of the current leakages can vary from extraneous segments appearing on the display to drifting zero levels or errors in readings. The problems Primarily occur when the printed circuit board is exposed to elevated temperature and humidity levels. To resolve any problems caused by the contamination, TSI is recalling instruments that are potentially affected. Instruments returned to TSI will be disassembled, printed board assemblies will be cleaned, and the instruments reassembled and recalibrated. Units will be returned with a new calibration and calibration certificate. As found data will not be taken unless specifically requested. We have determined that the following instruments potentially have this problem: VELOCICALC Models 8355, 8357, 8360, 8382, 8383, and 8388 with serial numbers beginning with the digits 604 through 606 or 9604 through 9606 VELOCICHECK Models 8330, 8340 with serial numbers beginning with the digits 9601 through 9606 ACCUBALANCE Model 8370 with serial numbers beginning with the digits 601 through 606 DP-CALC Models 8702, 8704 with serial numbers beginning with the digits 9604 through 9606 To arrange for returning the instrument to TSI, please call 800-777-8356 or (001) 612-490-2711 or fax 612-490-2874 and TSI personnel will provide a Returned Material Authorization (RMA) number and instructions on where and how to ship the instrument. We apologize for any inconvenience this potential problem may cause. If you have any questions, please call TSI at 800-777-8356. Sincerely, Richard R. Remiarz, Business Unit Manager Industrial Test Instruments Group Environmental Measurements and Controls Division nupicltr.doc *** END OF DOCUMENT ***

Page Last Reviewed/Updated Wednesday, March 24, 2021