Part 21 Report - 1996-641
ACCESSION #: 9608280084 Information & Support Services P.O. Box 3707 Seattle, WA 98124-2207 BOEING August 20, 1996 G-1151-SJA-96-537 Document Control Desk United States Nuclear Regulatory Commission Washington, D.C. 20555 Reference: a) Boeing Letter G-1151-RSO-92-365 dated August 31, 19921 R. S. Orr to the NRC Operations Center b) NRC Letter Docket No. 99901227 dated August 12, 1992; L. J. Norrholm to R. S. Orr; Subject: Response to 10 CFR 21 Inquiry Dear Sir or Madam: In accordance with the reference correspondence and 10 CFR 21, Boeing is sending the NRC the attached error notice(s) received from our, former software suppliers. Because of unknown current addresses, the following former customers were not notified: Reactor Controls, Inc. Echo Energy Consultants, Inc. Nuclear Applications and Systems Analysis Company (Japan) Nuclear Power Services Tenera Engineering Services Gibbs & Hill, Inc. Error notices have been sent to our other former customers. Very truly yours, Sandra J. Andrews Nuclear Administrator Phone: (206) 865-6248 FAX: (206) 865-4851 Mail Stop: 7A-33, or e-mail: Sandra.Andrews@PSS.Boeing.com Attachment(s): GTSTRUDL Program Report Form No. 96.20 Georgia Tech Computer Aided Structural Engineering Center Georgia Institute of Technology School of Civil & Environmental Engineering Atlanta, Georgia 30332-0355 USA 404 o 894 o 2260 404 o 894 o 8014 FAX August 8, 1996 Attention: Nuclear Administrator Boeing Information & Support Services P.O.Box 24346, M/S 7A-33 Seattle, Washington 98124-0346 RE: GT STRUDL Dear Sir or Madam: Enclosed please find copies of GTSTRUDL PROGRAM REPORT FORM No. 96.20 and a VENDOR ACKNOWLEDGEMENT FORM. Please sign and return the VENDOR ACKNOWLEDGEMENT FORM to acknowledge receipt of the GTSTRUDL Program Report. Thank you for reviewing the Program Report and for returning the Acknowledgement Form. Best regards, CASE Center Catherine Lee Configuration Control Manager CL/tlk Enclosures An Equal Education and Employment Opportunity Institution A Unit of the University System of Georgia GTSTRUDL Program Report Form GPRF No.: 96.20 DATE: August 7, 1996 FROM: Computer-Aided Structural Engineering Center Georgia Institute of Technology Atlanta, Georgia 30332-0355 SEVERITY LEVEL: x URGENT Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job. _ SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task. _ MINOR Problem can be worked around or problem poses high frustration factor. _ INFORMATIVE Documentation error, program usage tip, user inconveniences. Date Problem Confirmed August 7, 1996 Date Notification Sent August 9, 1996 Computers All Operating System All Version All versions prior to and including 96.01 Target Release for Correction 96.03 Director, ASD Signature Title R & D Division Kenneth Will August 7, 1996 Typed or Printed Name Date of Signature Signature Title Professional Services Division Typed or Printed Name Date of Signature Rev. 2.2 GTSTRUDL Program Report Form (Continued) GPRF No.: 96.20 DATE: August 7, 1996 DESCRIPTION The SECTION and LIST SECTION commands issued between two successive NONLINEAR ANALYSIS CONTINUE commands will cause the second NONLINEAR ANALYSIS CONTINUE command to abort: NONLINEAR ANALYSIS CONTINUE o o o SECTION FRACTIONAL NS 3 0.0 0.5 1.0 o o o NONLINEAR ANALYSIS CONTINUE (this command will abort) There is no work around other than remove the SECTION and LIST SECTION commands. Applicable sections of the User's Manual: The SECTION Command Section 2.1.14.5, Vol.1 Internal Member Results Output-- The LIST Command Section 2.1.14.6, Vol.1 The NONLINEAR ANALYSIS Command Section 2.5.5, Vol.3 Rev. 2.2 *** END OF DOCUMENT ***
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021