Skip to main content

Part 21 Report - 1996-207

ACCESSION #: 9602050205 Information & Support Services P.O. Box 3707 Seattle, WA 98124 2207 January 30, 1996 G-1151-SJA-96-088 Document Control Desk United States Nuclear Regulatory Commission Washington, D.C. 20555 BOEING Reference: a) Boeing Letter G-1151-RSO-92-365 dated August 31, 1992; R. S. Orr to the NRC Operations Center b) NRC Letter Docket No. 99901227 dated August 12, 1992; L. J. Norrholm to R. S. Orr; Subject: Response to 10 CFR 21 Inquiry Dear Sir or Madam: In accordance with the reference correspondence and 10 CFR 21, Boeing is sending the NRC the attached error notice(s) received from our former software suppliers. Because of unknown current addresses, the following former customers were not notified: Reactor Controls, Inc. Echo Energy Consultants, Inc. Nuclear Applications and Systems Analysis Company (Japan) Nuclear Power Services Tenera Engineering Services Error notices have been sent to our other former customers. Very truly yours, Sandra J. Andrews Nuclear Administrator G-1151 M/S 7A-33 (206) 865-6248 Attachment(s): ANSYS Class3 Error Reports 96-01, 96-02 and 96-03; ANSYS QA Notice AQ96-01; Class3 Error Report Summaries for Rev 5.1 and Rev. 5.2 ANSYS, Inc. 201 Johnson Road Telephone 412.746.3304 Houston, PA 15342-1300 Facsimile 412.746.9494 January 22, 1996 Dear Class3 Error Recipient: Enclosed with this letter you will find ANSYS Class3 Error Reports 96-01, 96-02, 96-03 and ANSYS QA Notice QA96-01. For your convenience, Class3 Error Report Summaries have been created for Rev. 5.1 and Rev. 5.2 and are also enclosed. These summaries are sorted by Class3 Error Number and also by keyword. Throughout 1995 you should have received Class3 Error Reports 95-01 up to and including 95-63. ANSYS QA Notices QA95-01 through QA95-10 were also issued throughout the year. There was a need to revise some reports this year and the following reports were also released: 93-105 R1, 94-41 R1, 94-52 R1, 94-68 R1, 94-01 R1, 95-10 R1, 95-07 R1, 95-21 R1 and 95-13 R1. If you are missing any of the above referenced reports please notify Bonny Podolek at 412-873-2858 and the missing reports will be supplied to You. Please take a moment also to review the ASC name and address that the reports are being sent to. If any changes should be incorporated into the address, please fill out the form attached to this letter and return it so that we can update our records. I would like to remind you that Class3 Error Reports and the Class3 Error Summaries are also available in ascii format via Internet. like to be added to the distribution list to receive reports in this fashion, simply send an email to bpodolek@ansys.com and include your email address, your name, company name and ANSYS license number. Reports sent via Internet do not replace the hard copy reports. The hard copy reports are still considered to be the official report. On behalf of the ANSYS, Inc. staff, I would like to extend to you and your associates, warm wishes for a prosperous year in 1996. Sincerely, ANSYS, Inc. William J. Bryan Quality Assurance Manager ANSYS Revision Identifier Description ANSYS revision identifiers consist of a major revision level, a minor revision level, a correction level, and occasionally a special version level. An example of how this is constructed is shown below: Figure omitted. Major revision level changes indicate that new features have been added to the program and that some level of program architecture change and/or file structure has occurred. Minor revision level changes also indicate that new features have been added to the program, but files are upwardly compatible. All known error fixes in included in both minor and major revisions. Changes to the collection level indicate that it is primarily an error correction release. Special version identifiers indicate that one or more additional minor changes have been made to the program, normally to circumvent an error. Special versions are not general releases to all ANSYS licensees, since they typically represent errors occurring only on one system, a subset of our customers who have specific graphics devices, etc. The ANSYS revision identifier(s) shown under "corrected in" on the front side of this Class3 Error Report indicates the first possible revision that could contain the correction. A major program change needed to fix an error can dictate that the next minor or major revision will contain the fix rather than the next correction level. For example, when errors were being reported while Rev. 4.3A was the latest production version, most Class3 error reports indicated that 4.3B was the "corrected in" revision. Others requiring significant code restructuring were reported as fixed in 4.4. Rev. 4.3B was never released, but Rev. 4.4 contained all error corrections noted as fixed in 4.3B. An identifier indicated under "corrected in" does not guarantee that a general release of that revision of ANSYS will occur. It does indicate that the correction is known and implemented in the coding that would be part of that general release. Equivalent Product Identifiers The ANSYS family of products occasionally undergoes name changes between revisions and/or changes in the functionality of derived products (such as ANSYS-PC/LINEAR). To minimize the potential for confusion in these areas, the important product name equivalences (similar program functionality and error content) are listed below. ANSYS/ED contains all errors the full ANSYS product, shown for starting at Rev. 5.0, and beyond, unless otherwise noted. PC/LINEAR is equivalent to WS/LINEAR at Rev. 4.4A, and ANSYS/LINEAR starting at Rev. 5.0. PC/LINEAR is equivalent to WS/THERMAL at Rev. 4.4A and ANSYS/THERMAL starting at Rev. 5.0. PREPPOST contains relevant the full ANSYS product, errors shown for for included pre- and postprocessing functionality ANSYS (Registered Trademark) CLASS3 ERROR REPORT ERROR NO: 96-01 KEYWORDS: POST1 SHELL NONLINEAR PDEF ETABLE PRNSOL PLNSOL DESCRIPTION OF ERROR: In POST1, for shell elements, (SHELL43, 91, 93, or 143) nonlinear data (items SEPL,SRAT,HPRE,EPEQ,PSV,PLWK) are used (ETABLE, PDEF, NSEL, NSORT commands) or displayed (PRNSOL,PLNSOL,PLESOL,*_/ GET commands) at the top of shell location (SHELL,TOP) instead of the location specified by the SHELL command. FIRST INCORRECT VERSION(S):*_/ CORRECTED IN:*_/ Rev. 5.0 Rev. 5.3 SUGGESTED USER ACTION FOR RUNNING ON UNCORRECTED VERSION: COMMENTS: The PRESOL command will display both top and bottom shell data. AUTHOR/CORRECTOR: DATE: January 19, 1996 Herb Mroz REVIEWED BY QA: DATE: January 19, 1996 William J. Bryan APPROVAL: DATE: January 19, 1996 John A. Swanson ________________________ *_/ If a product name is not included in the "first incorrect version", the full ANSYS program is implied. For products not listed, this error does not apply, but see the reverse side for equivalent product designations. Unless noted otherwise, this error report also applies to all revisions after the first incorrect one and prior to the corrected revision. ALL revisions after "corrected in" are corrected. Manual corrections are included in on-Line documentation as appropriate. Please see the reverse side of this sheet for additional information on ANSYS revision identifiers. FORM SASI-QA25 DEC 19, 1988 ANSYS(Registered Trademark) CLASS3 ERROR REPORT ERROR NO: 96-02 KEYWORDS: THERMAL ANALYSIS KZZ ORTHOTROPIC MATERIAL MATRIX REUSE DESCRIPTION OF ERROR: For PLANE75,78, and SOLID5,70,87,90,98,122,123, when the conductivities in the x and y directions (KXX and KYY) are not changed, but the conductivity in the z direction is changed between substeps, the results will be incorrect after the first substep. Conductivities may change by being temperature-dependent. FIRST INCORRECT VERSION(S):*_/ CORRECTED IN:*_/ Rev. 5.0 Rev. 5.3 ANSYS/Thermal Rev. 5.0A ANSYS/Thermal Rev. 5.3 SUGGESTED USER ACTION FOR RUNNING ON UNCORRECTED VERSION: If KZZ does change, make sure that KXX has a slight change also. COMMENTS: AUTHOR/CORRECTOR: DATE: January 19, 1996 Peter Kohnke REVIEWED BY QA: DATE: January 19, 1996 William J. Bryan APPROVAL: DATE: January 19, 1996 John A. Swanson ________________________ *_/ If a product name is not included in the "first incorrect version", the full ANSYS program is implied. For products not Listed, this error does not apply, but see the reverse side for equivalent product designations. Unless noted otherwise, this error report also applies to all revisions after the first incorrect one and prior to the corrected revision. ALL revisions after "corrected in" are corrected. Manual corrections are included in on-line documentation as appropriate. Please see the reverse side of this sheet for additional information on ANSYS revision identifiers. FORM SASI-QA25 DEC 19, 1988 ANSYS(Registered Trademark) CLASS3 ERROR REPORT ERROR NO: 96-03 KEYWORDS: MATERIAL PROPERTIES BEAM ELEMENTS PIPE ELEMENTS DESCRIPTION OF ERROR: The results are incorrect for certain line elements after the first substep when certain material properties (MP commands) change between substeps (such as caused by a temperature-dependent material property) and large deflections are not used (NLGEOM,OFF). The following specific cases are erroneous: 1. BEAM3,4,23,24,44,54 and PIPE16,59, if the shear modulus (GXY) is changed but Young's modulus (EX) is not changed. 2. PIPE17, the piping tee element, if any material property is changed. FIRST INCORRECT VERSION(S):*_/ CORRECTED IN:*_/ Rev. 5.0 Rev. 5.3 ANSYS/LinearPlus Rev. 5.0A ANSYS/LinearPlus Rev. 5.3 SUGGESTED USER ACTION FOR RUNNING ON UNCORRECTED VERSION: Use large deflections (NLGEOM,ON), even if it is not otherwise needed. For item 1, one can also make a small change in EX when there is a change in GXY. COMMENTS: AUTHOR/CORRECTOR: DATE: January 19, 1996 Peter Kohnke REVIEWED BY QA: DATE: January 19, 1996 William J. Bryan APPROVAL: DATE: January 19, 1996 John A. Swanson ______________________ *_/ If a product name is note included in the "first incorrect version", the full ANSYS program is implied. For products not listed, this error does not apply, but see the reverse side for equivalent product designations. Unless noted otherwise, this error report also applies to all revisions after the first incorrect one and prior to the corrected revision. ALL revisions after "corrected in" are corrected. Manual corrections are included in on-Line documentation as appropriate. Please see the reverse side of this sheet for additional information on ANSYS revision identifiers. FORM SASI-QA25 DEC 19, 1988 ANSYS QA NOTICE NOTICE NO: QA96-01 SUBJECT: POST1 NFORCE AXISYMMETRIC STRUCTURES DESCRIPTION: The NFORCE command has no specialization for axisymmetric structures. Therefore, the POST1 NFORCE command produces incorrect results for some loads when using axisymmetric structures. The NFORCE command treats all forces and moments as if they were in three- dimensional space. There will be a change in the documentation to clarify this limitation. AFFECTED VERSIONS: Rev. 4.0 - Rev. 5.2 Component Products Rev. 4.2 - Rev. 5.2 AUTHOR: DATE: January 19, 1996 Peter Kohnke REVIEWED BY QA: DATE: January 19, 1996 William J. Bryan APPROVAL: DATE: January 19, 1996 John A. Swanson Table "ANSYS 5.1 CLASS3 ERROR SUMMARY BY REPORT NUMBER", 3 pages, omitted. Table "ANSYS 5.1 CLASS3 ERROR SUMMARY KEYWORD SORT OF ALL REVISION 5.1. CLASS3 ERRORS Date of this report: 1/22/96", 8 pages, omitted. Table "ANSYS 5.2 CLASS3 ERROR SUMMARY BY REPORT NUMBER" omitted. Table "ANSYS 5.2 CLASS3 ERROR SUMMARY KEYWORD SORT OF ALL REVISION 5.2 CLASS3 ERRORS Date of this report: 1/22/96", 2 pages, omitted. *** END OF DOCUMENT ***

Page Last Reviewed/Updated Wednesday, March 24, 2021

Page Last Reviewed/Updated Wednesday, March 24, 2021