August 22, 1995
G-1151-SJA-95-313

Document Control Desk
United States Nuclear Regulatory Commission 
Washington, D.C. 20555

Reference: a)  Boeing Letter G-1151-RSO-92-365 dated August 31, 1992;
               R. S. Orr to the NRC Operations Center

          b)   NRC Letter Docket No. 99901227 dated August 12, 1992; L.
               J. Norrholm to R. S. Orr; Subject: Response to 10 CFR 21
               Inquiry

Dear Sir or Madam:

In accordance with the reference correspondence and 10 CFR 21, Boeing is
sending the NRC the attached error notice(s) received from our former
software suppliers.  Because of unknown current addresses, the following
former customers were not notified:

     Reactor Controls, Inc.

     Echo Energy Consultants, Inc.

     Nuclear Applications and Systems Analysis Company (Japan)

     Nuclear Power Services

Error notices have been sent to our other former customers.

Very truly yours,


Sandra J. Andrews
Nuclear Administrator
G-1151 M/S 7A-33
(206) 865-6248

Attachment(s): GTICES Program Response Form No. 95.15

Georgia Tech
                         Computer Aided Structural Engineering Center

                         Georgia Institute of Technology
                         School of Civil & Environmental Engineering
                         Atlanta, Georgia 30332 0355
                         USA
                         404 o 894 o 2260
                         404 o 894 o 8044 FAX

August 17, 1995

Attention: Nuclear Administrator
Boeing Information & Support Services 
P.O.Box 24346, M/S 7A-33
Seattle, Washington 98124-0346

RE: GT STRUDL

Dear Sir or Madam:

Enclosed please find a copy of GTICES PROGRAM REPORT FORM No. 95.15 and a
VENDOR ACKNOWLEDGEMENT FORM.  Please sign and return the VENDOR
ACKNOWLEDGEMENT FORM to acknowledge receipt of the GTICES Program Report.

Thank you for reviewing the Program Report and for returning the
Acknowledgement Form.

Best regards,
CASE Center

Catherine Lee
Configuration Control Manager

CL/jhb
Enclosures


                      GTSTRUDL Program Report Form

                                                  GPRF No.: 95.15
                                             DATE: August 17, 1995

FROM:     Computer-Aided Structural Engineering Center 
          Georgia Institute of Technology 
          Atlanta, Georgia 30332-0355

SEVERITY LEVEL

     URGENT         Problem results in incorrect answers which may not be
                    apparent or job aborts and cannot be recovered within
                    the session or job.

     SERIOUS        Problem results in incorrect answers which are
                    obvious or problem prevents completion of a
                    particular user's task.

x    MINOR          Problem can be worked around or problem poses high
                    frustration factor.

     INFORMATIVE    Documentation error, program usage tip, user
                    Inconveniences.

Date Problem Confirmed August 17, 1995

Date Notification Sent August 18, 1995

Computers PC Only

Operating System DOS

Version All versions including 92.01 Mod 0 and later

Target Release for Correction 95.02


                                             Manager, ASD
Signature                                    Title
R & D Division


Michael H. Swanger                           August 17, 1995
Typed or Printed Name                        Date of Signature


Signature                                    Title
Professional Services Division


Typed or Printed Name                        Date of Signature

                                                                 Rev. 2.2


                      GTSTRUDL Program Report Form
                               (Continued)

                                                       GPRF No.: 95.15
                                                  DATE: August 17, 1995

DESCRIPTION:

     Reinforced concrete P-[symbol omitted] analysis aborts if members
having variable properties are present in the model.  A workaround is to
represent each segment in the variable-property members as an individual
prismatic member.  This will require additional joints and members.

Applicable sections of the User's Manual:

Section 2.1.9.2, Volume 1     The MEMBER PROPERTIES Command
Section 8, Volume 4           Consideration of Column Slenderness

                                                                 Rev. 2.2

*** END OF DOCUMENT ***