Part 21 Report - 1995-181
ACCESSION #: 9506300257
Commonwealth Edison Company
1400 Opus Place
Downers Grove, IL, 60515
ComEd
June 21, 1995
U.S. Nuclear Regulatory Commission
Washington, DC 20555
Attention: Document Control Desk
Subject: Braidwood Station Units 1 and 2
Byron Station Units 1 and 2
Dresden Station Units 2, and 3
LaSalle County Station Units 1 and 2
Quad Cities Station Units 1 and 2
Zion Station Units 1 and 2
10 CFR Part 21 Interim Report 95-007
ComEd Amerace E7000 Series Relay Timers May
Be Used in Unqualified Configurations
NRC Dockets 50-456 and 50-457
NRC Dockets 50-454 and 50-455
NRC Dockets 50-237 and 50-249
NRC Dockets 50-373 and 50-374
NRC Dockets 50-254 and 50-265
NRC Dockets 50-295 and 50-304
Applicability
This notification is submitted in accordance with the requirements of 10
CFR Part 21. Section 21.21(a)(2).
Identification of Facilities and Components
Byron Nuclear Generating Station Units 1 and 2
Braidwood Nuclear Generating Station Units 1 and 2
Dresden Nuclear Generating Station Units 2 and 3
LaSalle Nuclear Generating Station Unit 1 and 2
Quad Cities Nuclear Generating Station Units 1 and 2
Zion Nuclear Generating Station Units 1 and 2
Amerace E7000 Series Relay Timers used in various safety related
applications at all 6 ComEd nuclear generating stations
k:dave:p21amer:1
Document Control Desk (2) June 21, 1995
Identification of Component Manufacturer/Supplier
Amerace Electronic Components
7474 Utilities Road
Punta Gorda, FL 333982
Nature of Defect
The defect is related to a notification from Amerace of a reduction in
contact rating for Amerace's E7000 Series relay timers. The published
rating was reduced for circuits serving loads rated at 1.0 amp at 125
VDC. The new rating is 0.5 amps at 125 VDC. Amerace requested that
ComEd review any DC applications with the E7000 series timer that may be
required to switch 125 VDC at 1.0 amp. Amerace indicated that, per test
data, the fragility level of the contact blocks was determined to be
between 0.68 amps and 0.71 amps at 125 VDC.
Time of Discovery
Commonwealth Edison Company first determined that the potential
misapplication of the Amerace E7000 relays could potentially adversely
affect safety related equipment and that the defect could be reportable
per 10CFR21 on April 25, 1995.
Number and Location of All Defective Components:
The Amerace relay timers are used in various safety related applications
at all six ComEd sites. The approximate numbers range from: 24 at
LaSalle Station, 33 at Quad Cities, 50 at Dresden, and 55 applications at
Zion, to approximately 250 applications at Byron and Braidwood Stations.
Corrective Actions:
All ComEd sites are evaluating the specific applications of the E7000
series relay timers at their individual stations, respectively. Because
of the unique configuration of each application and the detailed review
and evaluation that is required to determine whether a substantial safety
hazard exists, each site is responsible for dispositioning their own
relays. To date, three sites have completed their preliminary review and
no cases were found in which the E7000 series relay timers were
determined to adversely impact the operability of any safety related
equipment at ComEd.
k:dave:p21amer:2
Document Control Desk (3) June 21, 1995
10 CFR 21 Evaluation
At this time, the ComEd review indicates that there is a potential 10 CFR
Part 21 notification related to the Amerace E7000 series relay timers.
To date, no applications have been determined to meet the reportability
requirements of 10 CFR Part 21. However, the review of all applications
at ComEd has not been completed. It is anticipated that this evaluation
will be completed for all sites by 8/23/95.
Contacts
Questions pertaining to this notification should be addressed to:
Eric S. Steckhan
Nuclear Engineering Services
ComEd
1400 Opus Place, Suite 300
Downers Grove, IL 60515
(708) 663-7437
Sincerely,
I. M. Johnson
Licensing Operations Director
Nuclear Regulatory Services
cc: J. Martin, Regional Administrator-RIII
S. Dupont, Senior Resident Inspector (Braidwood)
H. Peterson, Senior Resident Inspector (Byron)
M. Leach, Senior Resident Inspector (Dresden)
P. Brochman, Senior Resident Inspector (LaSalle)
C. Miller, Senior Resident Inspector (Quad Cities)
R. Roton, Senior Resident Inspector (Zion)
k:dave:p21amer:3
*** END OF DOCUMENT ***
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021