Part 21 Report - 1995-168

ACCESSION #: 9507120216

                     Information & Support Services
                              P.O. Box 3707
                         Seattle, WA 98124-2207

BOEING

July 5, 1995
G-1151-SJA-95-253

Document Control Desk
United States Nuclear Regulatory Commission
Washington, D.C. 20555

Reference:     a)   Boeing Letter G-1151 -RSO-92-365 dated August 31,
                    1992; R. S. Orr to the NRC Operations Center

               b)   NRC Letter Docket No. 99901227 dated August 12, 1992;
                    L. J. Norrholm to R. S. Orr; Subject: Response to 10
                    CFR 21 Inquiry

Dear Sir or Madam:

In accordance with the reference correspondence and 10 CFR 21, Boeing is
sending the NRC the attached error notice(s) received from our former
software suppliers.  Because of unknown current addresses, the following
former customers were not notified:

     Reactor Controls, Inc.

     Echo Energy Consultants, Inc.

     Nuclear Applications and Systems Analysis Company (Japan)

     Nuclear Power Services

Error notices have been sent to our other former customers.

->   Please note the following changes:

     1.   Sandra J. Andrews has replaced R. S. Orr as Nuclear
          Administrator

     2    Because of organization changes within Boeing, our parent
          division is now Boeing Information & Support Services instead
          of Boeing Computer Services.  Our mailing address will remain
          the same.

Very truly yours,

Sandra J. Andrews
Nuclear Administrator
G-1151 M/S 7A-33
(206) 865-6248

Attachment(s): ANSYS Class3 Error Reports 95-37, 95-38, 95-39, 95-40,
               95-41 and 95-42.

               GTICES Program Report Form No. 95.14

ANSYS (Registered Trademark)

                         ANSYS, Inc.
                         201 Johnson Road         Telephone 412.746.3304
                         Houston, PA 15342-1300   Facsimile 412.746.9494

                             June 16, 1995

Dear Class3 Error Recipient:

     Enclosed you will find ANSYS Class3 Error Reports 95-37, 95-38,
95-39, 95-40, 95-41 and 95-42.

                              Sincerely,

                              ANSYS, Inc.

                              Prashant Ambe
                              Quality Assurance Manager

Enclosures

                  ANSYS Revision Identifier Description

     ANSYS revision identifiers consist of a major revision level, a
minor revision level, a correction level, and occasionally a special
version level.  An example of how this is constructed is shown below:

Figure "5.0A-10" omitted.

     Major revision level changes indicate that new features have been
added to the program and that some level of program architecture change
and/or file structure has occurred.  Minor revision level changes also
indicate that new features have been added to the program, but files are
upwardly compatible.  All known error fixes are included in both minor
and major revisions.  Changes to the correction level indicate that it is
primarily an error correction release.  Special version identifiers
indicate that one or more additional minor changes have been made to the
program, normally to circumvent an error.  Special versions are not
general releases to all ANSYS licensees, since they typically represent
errors occurring only on one system, a subset of our customers who have
specific graphics devices, etc.

     The ANSYS revision identifier(s) shown under "corrected in" on the
front side of this Class3 Error Report indicates the first possible
revision that could contain the correction A major program change needed
to fix an error can dictate that the next minor or major revision will
contain the fix rather than the next correction level.  For example, when
errors were being reported while Rev.4.3A was the latest production
version, most Class3 error reports indicated that 4.3B was the "corrected
in" revision.  Others requiring significant code restructuring were
reported as fixed in 4.4. Rev. 4.3B was never released, but Rev.  4.4
contained all error corrections noted as fixed in 4.3B.

     An identifier indicated under "corrected in" does not guarantee that
a general release of that revision of ANSYS will occur.  It does indicate
that the correction is known and implemented in the coding that would be
part of that general release.

                     Equivalent Product Identifiers

     The ANSYS family of products occasionally undergoes name changes
between revisions and/or changes in the functionality of derived products
(such as ANSYS-PC/LINEAR).  To minimize the potential for confusion in
these areas, the important product name equivalences (similar program
functionality and error content) are listed below.

     ANSYS/ED       contains all errors           the full ANSYS product,
                    shown for                     starting at Rev. 5.0,
                                                  and beyond unless
                                                  otherwise noted.

     PC/LINEAR      is equivalent to              WS/LINEAR at Rev.4.4A.
                                             and  ANSYS starting at
                                                  Rev. 5.0.

     PC/THERMAL     is equivalent to              WS/THERMAL at Rev.4.4A,
                                             and  ANSYS/THERMAL starting
                                                  at Rev. 5.0.

     PREPPOST       contains relevant             the full ANSYS product,
                    errors shown for              for included pre- and
                                                  postprocessing
                                                  functionality

            ANSYS (Registered Trademark) CLASS3 ERROR REPORT

                                                  ERROR NO: 95-37

KEYWORDS:      FLOTRAN             FLUID142            ELEM142

DESCRIPTION OF ERROR:

     Three-dimensional FLOTRAN models using FLUID142 elements solved in
cylindrical coordinates (KEYOPT(3)=3) with a z-direction acceleration
(ACEL command) yield incorrect velocity and pressure solutions.

FIRST INCORRECT VERSION(S):*_/               CORRECTED IN:*_/

Rev. 5.1                                     Rev. 5.3
ANSYS/FLOTRAN Rev. 5.1                       ANSYS/FLOTRAN Rev. 5.3

SUGGESTED USER ACTION FOR RUNNING ON UNCORRECTED VERSION:

COMMENTS:

AUTHOR/CORRECTOR:                            DATE: June 15, 1995
                    Mark A. Troscinski

REVIEWED BY QA:                              DATE: June 15, 1995
                    Prashant Ambe

APPROVAL:                                    DATE: June 15, 1995
                    David Conover

*_/If a product name is not included in the "first incorrect version",
the full ANSYS program is implied.  For products not listed, this error
does not apply, but see the reverse side for equivalent product
designations.

Unless noted otherwise, this error report also applies to all revisions
after the first incorrect one and prior to the corrected revision.  All
revisions after "corrected in" are corrected.  Manual corrections are
included in on-line documentation as appropriate.  Please see the reverse
side of this sheet for additional information on ANSYS revision
identifiers.

                                                  FORM SASI-QA25
                                                  DEC 19, 1988

            ANSYS (Registered Trademark) CLASS3 ERROR REPORT

                                                  ERROR NO: 95-38

KEYWORDS:      FLOTRAN        FLUID141       ELEM141

DESCRIPTION OF ERROR:

     Two-dimensional FLOTRAN models using triangular FLUID141 elements
solved in cylindrical coordinates (KEYOPT(3)=3) yield incorrect pressure
solutions.

FIRST INCORRECT VERSION(S):*_/          CORRECTED IN:*_/

Rev. 5.1                                Rev. 5.2
ANSYS/FLOTRAN Rev. 5.1                  ANSYS/FLOTRAN Rev. 5.2

SUGGESTED USER ACTION FOR RUNNING ON UNCORRECTED VERSION:

COMMENTS:

AUTHOR/CORRECTOR:                            DATE: June 15, 1995
                    Mark A. Troscinski

REVIEWED BY QA:                              DATE: June 15, 1995
                    Prashant Ambe

APPROVAL:                                    DATE: June 15, 1995
                    David Conover

*_/If a product name is not included in the "first incorrect version",
the full ANSYS program is implied.  For products not listed, this error
does not apply, but see the reverse side for equivalent product
designations.

Unless noted otherwise, this error report also applies to all revisions
after the first incorrect one and prior to the corrected revision.  All
revisions after "corrected in" are corrected.  Manual corrections are
included in on-line documentation as appropriate.  Please see the reverse
side of this sheet for additional information on ANSYS revision
identifiers.

                                                  FORM SASI-QA25
                                                  DEC 19, 1988

            ANSYS (Registered Trademark) CLASS3 ERROR REPORT

                                                  ERROR NO: 95-39

KEYWORDS:      FLOTRAN             ELEM142        FLUID142

DESCRIPTION OF ERROR:

     Three-dimensional FLOTRAN models, using FLUID142 elements, solved in
Cartesian coordinates (KEYOPT(3)=0, default) yield incorrect pressure
solutions when solved with a rotating frame of reference (CGOMGA or OMEGA
commands).

FIRST INCORRECT VERSION(S):*_/               CORRECTED IN:*_/

Rev. 5.1                                     Rev. 5.3
ANSYS/FLOTRAN Rev. 5.1                       ANSYS/FLOTRAN Rev. 5.3

SUGGESTED USER ACTION FOR RUNNING ON UNCORRECTED VERSION:

COMMENTS:

AUTHOR/CORRECTOR:                            DATE: June 15, 1995
                    Mark A. Troscinski

REVIEWED BY QA:                              DATE: June 15, 1995
                    Prashant Ambe

APPROVAL:                                    DATE: June 15, 1995
                    David Conover

*_/If a product name is not included in the "first incorrect version",
the full ANSYS program is implied.  For products not listed, this error
does not apply, but see the reverse side for equivalent product
designations.

Unless noted otherwise, this error report also applies to all revisions
after the first incorrect one and prior to the corrected revision.  All
revisions after "corrected in" are corrected.  Manual corrections are
included in on-line documentation as appropriate.  Please see the reverse
side of this sheet for additional information on ANSYS revision
identifiers.

                                                  FORM SASI-QA25
                                                  DEC 19, 1988

            ANSYS (Registered Trademark) CLASS3 ERROR REPORT

                                                  ERROR NO: 95-40

KEYWORDS: *GET      *VGET     *ELEMENT       *VOLUME        *AREA

DESCRIPTION OF ERROR:

     When *GET (or *VGET) is used before solution to retrieve the volume
or area of an element (*GET,Par,ELEM,n,Item 1 where Item 1 is AREA or
VOLU), the resulting parameter value may be negative depending on the
element node order.  This is most likely to occur if the element was
created by the direct generation method.

FIRST INCORRECT VERSION(S):*_/               CORRECTED IN:*_/

Rev. 5.0                                     Rev. 5.2
Component Products Rev. 5.0                  Component Products Rev. 5.2

SUGGESTED USER ACTION FOR RUNNING ON UNCORRECTED VERSION:

     Use the absolute value function (ABS) to change a negative volume or
area to a positive value.

COMMENTS:

AUTHOR/CORRECTOR:                            DATE: June 15, 1995
                    Krishna Raichur

REVIEWED BY QA:                              DATE: June 15, 1995

                    Prashant Ambe

APPROVAL:                                    DATE: June 15, 1995
                    David Conover

*_/If a product name is not included in the "first incorrect version",
the full ANSYS program is implied.  For products not listed, this error
does not apply, but see the reverse side for equivalent product
designations.

Unless noted otherwise, this error report also applies to all revisions
after the first incorrect one and prior to the corrected revision.  All
revisions after "corrected in" are corrected.  Manual corrections are
included in on-line documentation as appropriate.  Please see the reverse
side of this sheet for additional information on ANSYS revision
identifiers.

                                                  FORM SASI-QA25
                                                  DEC 19, 1988

            ANSYS (Registered Trademark) CLASS3 ERROR REPORT

                                                  ERROR NO: 95-41

KEYWORDS:      AUX12     RADIATION VlEW FACTORS   NON-HIDDEN METHOD

DESCRIPTION OF ERROR:

     The view factors computed using the AUX12 radiation matrix utility
may be in error when all of the following conditions are met:

     1.   3-D radiation view factors are requested (GEOM=0),

     2.   Non-hidden method is used (VTYPE=1),

and  3.   any of the SHELL57 elements used to model the radiating
          surfaces are triangular.  (Nodes K and L are the same.)

FIRST INCORRECT VERSION(S):*_/               CORRECTED IN:*_/

Rev. 5.0                                     Rev. 5.3

SUGGESTED USER ACTION FOR RUNNING ON UNCORRECTED VERSION:

     Use all quadrilateral elements.

COMMENTS:

AUTHOR/CORRECTOR:                            DATE: June 15, 1995
                    Charles Rajakumar

REVIEWED BY QA:                              DATE: June 15, 1995
                    Prashant Ambe

APPROVAL:                                    DATE: June 15, 1995
                    David Conover

*_/If a product name is not included in the "first incorrect version",
the full ANSYS program is implied.  For products not listed, this error
does not apply, but see the reverse side for equivalent product
designations.

Unless noted otherwise, this error report also applies to all revisions
after the first incorrect one and prior to the corrected revision.  All
revisions after "corrected in" are corrected.  Manual corrections are
included in on-line documentation as appropriate.  Please see the reverse
side of this sheet for additional information on ANSYS revision
identifiers.

                                                  FORM SASI-QA25
                                                  DEC 19, 1988

            ANSYS (Registered Trademark) CLASS3 ERROR REPORT

                                                  ERROR NO: 95-42

KEYWORDS:      GUI            BFE            CURRENT DENSITY

DESCRIPTION OF ERROR:

     If both 2-D (PLANE13 or PLANE53) and 3-D (SOLID62 or SOLID97)
magnetic element types are defined (ET command), the current density
dialog box in the Graphical User Interface (GUI) has an additional JSZ
input field.  This causes the phase angle (VAL4) to be written in the
wrong field of the BFE command, which may result in incorrect application
of current density load.  The menu path to this item is as follows:
(Solution) or (Preprocessor -> Loads) then Apply -> Magnetic - Curr
Density -> On Element.

FIRST INCORRECT VERSION(S):*_/               CORRECTED IN:*_/

Rev. 5.1                                     Rev. 5.2

SUGGESTED USER ACTION FOR RUNNING ON UNCORRECTED VERSION:

     Type the BFE command in the input window of ANSYS.

COMMENTS:

AUTHOR/CORRECTOR:                            DATE: June 15, 1995
                    Eric Clevenger

REVIEWED BY QA:                              DATE: June 15, 1995
                    Prashant Ambe

APPROVAL:                                    DATE: June 15, 1995
                    David Conover

*_/If a product name is not included in the "first incorrect version",
the full ANSYS program is implied.  For products not listed, this error
does not apply, but see the reverse side for equivalent product
designations.

Unless noted otherwise, this error report also applies to all revisions
after the first incorrect one and prior to the corrected revision.  All
revisions after "corrected in" are corrected.  Manual corrections are
included in on-line documentation as appropriate.  Please see the reverse
side of this sheet for additional information on ANSYS revision
identifiers.

                                                  FORM SASI-QA25
                                                  DEC 19, 1988

Georgia Tech             Computer Aided Structural Engineering Center
                         Georgia Institute of Technology
                         School of Civil & Environmental Engineering
                         Atlanta, Georgia 30332-0355
                         USA
                         404-894-2260
                         404-894-8014 FAX

June 28, 1995

Attention: Nuclear Administrator
Boeing Computer Services
P.O. Box 24346, M/S 7A-33
Seattle, Washington 98124-0346

RE: GT STRUDL

Dear Sir or Madam:

Enclosed please find a copy of GTICES PROGRAM REPORT FORM No. 95.14 and a
VENDOR ACKNOWLEDGEMENT FORM.  Please sign and return the VENDOR
ACKNOWLEDGEMENT FORM to acknowledge receipt of the GTICES Program Report.

Thank you for reviewing the Program Report and for returning the
Acknowledgement Form.

Best regards,
CASE Center

Catherine Lee
Configuration Control Manager

CL/jhb
Enclosures

                      GTSTRUDL Program Report Form

                                             GPRF No.: 95.14

                                                  DATE:  June 27, 1995

FROM:     Computer-Aided Structural Engineering Center
          Georgia Institute of Technology
          Atlanta, Georgia 30332-03055

SEVERITY LEVEL:

X    URGENT         Problem results in incorrect answers which may not be
                    apparent or job aborts and cannot be recovered within
                    the session or job.

     SERIOUS        Problem results in incorrect answers which are
                    obvious or problem prevents completion of a
                    particular user,s task.

     MINOR          Problem can be worked around or problem poses high
                    frustration factor.

     INFORMATIVE    Documentation error, program usage tip, user
                    inconveniences.

Date Problem Confined  June 27, 1995

Date Notification Sent  June 29, 1995

Computers  DEC VAX, IBM RS6000, SUN, PC

Operating System  VMS (DEC VAX), AIX (IBM RS6000), Solaris (SUN), DOS

Version All version including 93.01 and late

Target Release for Correction 95.02

                                             Manager, ASD
Signature                                    Title
R & D Division

Michael H. Swanger                           June 27, 1995
Typed or Printed Name                        Date of Signature

Signature
Professional Services Division               Title

Typed or Printed Name                        Date of Signature

                                                            Rev. 2.2

                      GTSTRUDL Program Report Form
                               (Continued)

                                             GPRF No.: 95.14

                                               DATE: June 27, 1995
DESCRIPTION:

     The split solver ASSEMBLE (FOR STATICS/DYNAMICS) command ignores the
presence of elastic member end connections if member loads or
conventional member releases are also present in the model.  Any
subsequent split solver static or dynamic analysis execution will not
reflect the specified elastic member end connections.  The work around is
to use the STIFFNESS ANALYSIS command for static analysis and the DYNAMIC
ANALYSIS command for dynamic analysis instead of the split solver
commands.

Applicable sections of the User's Manual:

Section 2.1.8.2, Volume 1          The MEMBER RELEASES Command
Section 2.1.14.2, Volume 1         The STIFFNESS ANALYSIS Command
Section 2.1.14.3, Volume 1         The Split Solver Commands for Static
                                   Analysis
Section 2.4.5.4, Volume 3          The DYNAMIC ANALYSIS Command
Section 2.3.5.5, Volume 3          The Split Solver for Dynamic Analysis

                                                            Rev. 2.2

*** END OF DOCUMENT ***