Part 21 Report - 1995-166
ACCESSION #: 9505180280
The HARRISON STEEL CASTINGS CO.
POST OFFICE BOX 60 PHONE 317-762-2481
ATTICA,INDIANA 47918
March 24,1995
US Nuclear Regulatory Commission
Region III
801 Warrenville Road
Lisle, IL 60532-4351
Reference: NRC License No. 13-02141-01, Amendment 25
Subject: Equipment Breakdown
The Gamma Ray Department called me yesterday afternoon to report that
they noticed smoke coming from the Amersham Model 957 Automatic Exposure
controller which was installed with a model 680 Cobalt 60 projector at
our north exposure room this past December. They terminated the exposure
by manually cranking the source back into 680 projector. Our electrician
determined that a capacitor on a circuit board in the 957 had failed.
The extent of any other damage was not determined. Amersham was
notified, and requested that we return the 957 for repair. They are to
send out a return authorization and instructions.
The radiographers asked if they could continue using the manual crank to
operate the cobalt 60 source until the 957 was actually removed for
return to Amersham. They were about half finished with a large casting
that required a rather elaborate setup. Although our license does not
specifically address this question, it was my opinion that we would not
be in violation by continuing to radiograph the casting as described.
This opinion was based on the following reasons.
1. The only functions that were not working normally were the
automatic positioning of the source, the timer, and the
automatic retraction if someone passed the warning gate and
broke the photoelectric beam while the source was exposed. The
failure did not affect the exposure device, control cable, or
crank.
2. The alarm and warning light interlock system were completely
functional except as described above. This was verified during
the quarterly audit of this date.
3. The iridium 192 camera in the same exposure vault is operated
manually. The source does not automatically retract when the
photoelectonic beam is broken.
4. The radiographers do not deviate from their normal
Page 1 of 2
practices of maintaining surveillance or locking off the
exposure area during exposures, always carrying an operable and
calibrated survey meter into the exposure rooms, etc.
This is not a reportable event under 10 CFR; however, I am providing the
information to forstall any confusion at some later date.
Please contact me if you have any comments or desire additional
information.
Sincerely yours,
The Harrison Steel Casting Company
W.D. Hollander, RSO
cc: R. Shepherd
H. McBride
Page 2 of 2
*** END OF DOCUMENT ***