Part 21 Report - 1995-121
95120 ACCESSION #: 9505300147 FAX Message TSI TSI Incorporated 1 800 876 9874 Environmental Measurements & Controls Division Tel: 612 490 2888 500 Cardigan Road Fax 612 490 2874 Shoreview, MN 55126-3996 Date: April 24, 1995 Organization: Nuclear Regulatory Commission Attn: Operations Center FAX: 301-816-5151 Tel: 301-816-5100 From: Judie Weyandt Re: 10 CFR Ch. (1-1-95 Edition) [Section] 21.21(a)(1) Pages: 3 The attached documents are being faxed to the NRC Operations Center to meet the notification requirements to the above-referenced section. If you have any questions, please feel free to contract TSI Incorporated at 800-876-9874. Environmental Measurements 612 490 2888 and Controls Division Fax: 612 490 2874 500 Cardigan Road P.O. Box 64394 St. Paul, MN 55164 U.S.A. YOUR IMMEDIATE ATTENTION REQUESTED Calibration Error Affecting Some Air Velocity Test Instruments April 24, 1995 Dear Quality Assurance Manager: This letter is being mailed to all NUPIC members. Acting in accordance with the requirements of MIL Standard 45662A, we are sending the attached letter to all identified owners of the following instruments within the next 30 days: VELOCICALC (Registered Trademark) Models 8350, 8352, 8355, 8357, 8360 Air Velocity Transducer Models 8450, 8460 and 8470 If you have any questions, please contact me at 800-876-9874. Sincerely, Claudia K. Wood, Product Engineer Environmental Measurements & Controls Division Environmental Measurements 612 490 2888 and Controls Division Fax: 612 490 2874 500 Cardigan Road P.O. Box 64394 St. Paul, MN 55164 U.S.A. TSI YOUR IMMEDIATE ATTENTION REQUESTED Calibration Error Affecting Some Air Velocity Test Instrument April 24, 1995 Attn: Quality Assurance Manager Calibration Laboratory Manager Dear Valued TSI Customer: TSI values its reputation as a provider of high quality, accurate measurement instruments. As part of our on-going evaluation of our manufacturing processes, we have identified an error in high air velocity calibrations. We have not identified any error at low velocities (below 250 feet per minute). From 250 to 1000 fpm the error steadily increases from zero to approximately 2.25%. The error remains constant at approximately 2.25% at velocities higher than 1000 fpm. For example: If the instrument displays 1000 fpm, the true velocity would be 1020 fpm. Figure omitted. IMPORTANT: The identified error affects the following instruments: VELOCICALC [Registered Trademark] Models 8350, 8352, 8355, 8357 and 8360 Air Velocity Transducers Models 8450, 8460 and 8470 This calibration error affects both new instruments and recalibrated instruments. Therefore, in our interest of maintaining high value for our instrument users, TSI will temporarily provide velocity recalibrations at no charge on the above-referenced models manufactureded or serviced between April 1, 1994 and April 19, 1995. This temporary offer expires on July 31, 1995. If you are a user of the VELOCICALC [Registered Trademark] Plus Model 8360 and you wish to have the humidity and pressure functions recalibrated as well, we will provide this service at a reduced rate of $100. Please contact our Customer Support Service Group at 800-876-9874 to schedule the return of your instrument for recalibration. We value our customers and apologize for any inconvenience this may have caused you. *** END OF DOCUMENT ***
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021