Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Part 21 Report - 1995-107

ACCESSION #: 9504180193

                              Boeing Computer Services
                              P.O. Box 24346
                              Seattle. WA 98124-0346


BOEING


April 11, 1995
G-1151-RSO-95-168

Document Control Desk
United States Nuclear Regulatory Commission
Washington, D.C. 20555

Reference: a)  Boeing Letter G-1151-RSO-92-365 dated August 31, 1992;
               R.S. Orr to the NRC Operations Center

           b)  NRC Letter Docket No. 99901227 dated August 12, 1992; L.
               J. Norrholm to R. S. Orr; Subject: Response to 10 CFR 21
               Inquiry

Dear Sir or Madam:

In accordance with the reference correspondence and 10 CFR 21, Boeing is
sending the NRC the attached error notice(s) received from our former
software suppliers.  Because of unknown current addresses, the following
former customers were not notified:

          Reactor Controls, Inc.

          Echo Energy Consultants, Inc.

          Nuclear Applications and Systems Analysis Company (Japan)

          Nuclear Power Services

Error notices have been sent to our other former customers.

Very truly yours,

R. S. Orr
Nuclear Administrator
G-1151 M/S 7A-33
(206) 865-6248

Attachment(s): GTICES Program Report Form No. 95.07



Georgia Tech             Computer Aided Structural Engineering Center


                         Georgia Institute of Technology,
                         School of Civil & Environmental Engineering
                         Atlanta, Georgia 30332-0355
                         USA
                         404 o 894 o 2260
                         404 o 894 o 8013 FAX

March 29, 1995


Attention: Nuclear Administrator
Boeing Computer Services
P.O. Box 24346, M/S 7A-33
Seattle, Washington 98124-0346

RE: GT STRUDL

Dear Sir or Madam:

Enclosed please find a copy of GTICES PROGRAM REPORT FORM No. 95.07 and a
VENDOR ACKNOWLEDGEMENT FORM.  Please sign and return the VENDOR
ACKNOWLEDGEMENT FORM to acknowledge receipt of the GTICES Program Report.

Thank you for reviewing the Program Report and for returning the
Acknowledgement Form.

Best regards,
CASE Center

Catherine Lee
Configuration Control Manager

CL/apw
Enclosures


                         GTSTRUDL Program Report Form

                                             GPRF No.: 95-07

                                             DATE: March 28, 1995

FROM:     Computer-Aided Structural Engineering Center
          Georgia Institute of Technology
          Atlanta, Georgia 30332-0355

SEVERITY LEVEL:

x    URGENT         Problem results in incorrect answers which may not be
                    apparent or job aborts and cannot be recovered within
                    the session or job.

--   SERIOUS        Problem results in incorrect answers which are
                    obvious or problem prevents completion of a
                    particular user's task.

--   MINOR          Problem can be worked around or problem poses high
                    frustration factor.

--   INFORMATIVE    Documentation error, program usage tip, user
                    inconveniences.

Date Problem Confirmed   March 28, 1995

Date Notification Sent   March 30, 1995

Computers      All but PC

Operating System    All

Version   All versions prior to and including 9401

Target Release for Correction 95.01


Signature                               Title
R & D Division


Typed or Printed Name                   Date of signature


Signature                               Title
Professional Services Division


Typed or Printed Name                   Date of Signature

                                                       Rev. 2.2


                      GTSTRUDL Program Report Form
                               (Continued)

                                                  GPRF No.:  95.07

                                                  DATE: March 28, 1995

DESCRIPTION:

     In the MODEL MERGE function of GTModeler, a model restored with the
NEW MERGE menu selection causes STRUDL to abort when the merge is
performed and section properties have been specified.  Typically, NEW
MERGE would be used to restore a model for a second merge.  A work-around
is to exit Modeler to the command mode of STRUDL after the, First merge
and then to.  reenter Modeler in order to perform the second merge.

Relevant Documentation:

     MERGE        - GTSTRUDL User's Manual, Volume 6,
                         Chapter 15.
     COMMAND MODE - GTSTRUDL User's Manual, Volume 6,
                         Section 3. 11.

                                                            Rev. 2.2


*** END OF DOCUMENT ***

Page Last Reviewed/Updated Wednesday, March 24, 2021

Page Last Reviewed/Updated Wednesday, March 24, 2021