Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Part 21 Report - 1995-100

ACCESSION #:  9502010239

                         Boeing Computer Services
                         P.O. Box 24346
                         Seattle, WA 98124-0346

January 23, 1995
G-1151-RSO-95-057

Document Control Desk
United States Nuclear Regulatory Commission 
Washington, D.C. 20555

BOEING

Reference:     a)   Boeing Letter G-1151-RSO-92-365 dated August 31,
                    1992; R. S. Orr to the NRC Operations Center

               b)   NRC Letter Docket No. 99901227 dated August 12, 1992;
                    L. J. Norrholm to R. S. Orr; Subject: Response to 10
                    CFR 21 Inquiry

Dear Sir or Madam:

In accordance with the reference correspondence and 10 CFR 21, Boeing is
sending the NRC the attached error notice(s) received from our former
software suppliers.  Because of unknown current addresses, the following
former customers were not notified:

     Reactor Controls, Inc.
     
     Echo Energy Consultants, Inc.

     Nuclear Applications and Systems Analysis Company (Japan)

     Nuclear Power Services

Error notices have been sent to our other former customers.

Very truly yours,


R. S. Orr
Nuclear Administrator
G-1151 M/S 7A-33
(206) 865-6248

Attachment(s): GTICES Program Report Form No. 95.01


Georgia Tech             Computer Aided Structural Engineering Center

                         Georgia Institute of Technology
                         School of Civil & Environmental Engineering
                         Atlanta, Georgia 30332-0355
                         USA
January 20, 1995         404-894-2260
                         404-894-8014 FAX

Attention: Nuclear Administrator
Boeing Computer Services
P. O. Box 24346, M/S 7A-33
Seattle, Washington 98124-0346

RE:  GT STRUDL

Dear Sir or Madam:

Enclosed please find a copy of the GTICES PROGRAM REPORT FORM No. 95.01
and a VENDOR ACKNOWLEDGEMENT FORM.  Please sign and return the VENDOR
ACKNOWLEDGEMENT FORM to acknowledge receipt of the GTICES Program Report.

Thank you for reviewing the Program Report and for returning the
Acknowledgement Form.

Best regards,
CASE Center


Catherine Lee
Configuration Control Manager

CL/apw
Enclosures


                      GTSTRUDL Program Report Form

                                                  GPRF No.: 95-01

                                                  DATE: January 20, 1995

FROM:     Computer-Aided Structural Engineering Center 
          Georgia Institute of Technology 
          Atlanta, Georgia 30332-0355

SEVERITY LEVEL:

     URGENT         Problem results in incorrect answers which may not be
                    apparent or job aborts and cannot be recovered within
                    the session or job.

x    SERIOUS        Problem results in incorrect answers which are
                    obvious or problem prevents completion of a
                    particular user's task.

     MINOR          Problem can be worked around or problem poses high
                    frustration factor.


     INFORMATIVE    Documentation error, program usage tip, user
                    inconveniences.


Date Problem Confirmed  January 20, 1995

Date Notification Sent  January 20, 1995

Computers  RS600 (IBM)

Operating System  AIX

Version  94.01

Target Release for Correction  95.01


                                             Developer
Signature                               Title
R & D Division

  Robert Abernathy                           1-20-95
Typed or Printed Name                   Date of Signature


Signature                               Title
Professional Services Division


Typed or Printed Name                   Date of Signature

                                                                 Rev. 2.2


                      GTSTRUDL Program Report Form
                               (Continued)

                                             GPRF No.:  95.01

                                             DATE:  January 20, 1995

DESCRIPTION:

     SAVE files created with versions 92.01 and earlier cannot be
completely RESTORED with version 94.01(RS only).  No error message will
appear at "RESTORE" but STIFFNESS ANALYSIS will cause error messages
beginning with "#" (i.e. "IFINDF: Array level was not defined as full")
if an analysis was performed in the original SAVE files.  Results should
not be used.  If you wish to use 94.01 RESTORE to review an older SAVE
file, use a COPY of the original SAVE file.

                                                                 Rev. 2.2


*** END OF DOCUMENT ***

Page Last Reviewed/Updated Wednesday, March 24, 2021

Page Last Reviewed/Updated Wednesday, March 24, 2021