Part 21 Report - 1995-081
ACCESSION #: 9503300105
BW/IP
BW/IP International, Inc.
Byron P.O. Box Los Angeles Telephone
Jackson 2017 California 213 587 6171
Pumps Terminal 90051 Telex
Annex 677233
United Fax
Centrifugal 213 589 2080
Pumps
Pump
Division
27 March, 1995
U. S. Nuclear Regulatory Commission
Attn: Document Control Desk
Washington, D.C. 20555
Notification Pursuant to Title 10, CFR, Part 21
Gentlemen:
This letter transmits a Notification of Defects and Non-conformance in
accordance with the requirements of 10 CFR, Part 21. The attached
Notification, CFRN 95-01, reports a condition which effects
electrohydraulic damper actuators supplied by BW/IP.
This transmittal completes the notification requirements on this issue.
Very truly yours,
D. A. Gibson
Manager, Nuclear Products Operations
Attach.
cc: Mr. F.J. Costanzo, Manager of Engineering
Mr. R.D. Ham, Manager of Quality
Mr. K.A. Huber, Chairman, Part 21 Evaluation Board
Mr. W.A. Klenner, Product Manager
Mr. K.B. Lemmon, Manager, Field Service Operations
NOTIFICATION NO. CFRN 95-01
NOTIFICATION OF A REPORTABLE DATE: 24 March 1995
ISSUE PURSUANT TO 10 CFR 21
TO: U. S. Nuclear Regulatory Commission
Attn: Document Control Desk
Washington, D.C. 20555
NAME AND ADDRESS OF INDIVIDUAL INFORMING THE COMMISSION:
Mr. David Gibson
BW/IP International, Inc.
Pump Division
2300 East Vernon Avenue
Vernon, CA 90058
(213) 587-(illegible)171
For Technical Information Contact: Dr. Kent Huber
BW/IP Evaluation No. CFR 95-001
IDENTIFICATION OF THE FACILITY, THE ACTIVITY, OR THE BASIC COMPONENT
SUPPLIED FOR SUCH FACILITY OR ACTIVITY WITHIN THE UNITED STATES WHICH
FAILS TO COMPLY OR CONTAINS A DEFECT:
Basic Component: Electromechanical Relay
Borg-Warner Part Number 7238908
IDENTIFICATION OF THE FIRM SUPPLYING THE BASIC COMPONENT WHICH FAILS
TO
COMPLY OR CONTAINS A DEFECT:
BW/IP International, Inc.
Pump Division
Successor to:
BW/IP International, Inc.
Fluid Controls Division
Successor to:
Borg-Warner Nuclear Valve Division
7500 Tyrone Avenue
Van Nuys, CA 91409
Page 1
NOTIFICATION NO. CFRN 95-01
NATURE OF THE DEFECT OR FAILURE TO COMPLY AND THE SAFETY HAZARD
WHICH IS
CREATED OR COULD BE CREATED BY SUCH DEFECT OR FAILURE TO COMPLY:
Relay is installed in an electro-hydraulic rotary damper
actuator.
Part supplied to utility was capable of performing the required
function but was incorrectly certified. The component was
purchased and supplied as "commercial". It was certified as
being built under an approved Appendix B quality program.
THE DATE ON WHICH THE INFORMATION OF SUCH DEFECT OR FAILURE TO
COMPLY WAS
OBTAINED:
BW/IP International was advised of the potential non-
conformance by Houston Lighting and Power on 27 February 1995.
An Evaluation was opened on 9 March 1995 to determine if a
reportable deficiency existed.
IN THE CASE OF A BASIC COMPONENT WHICH CONTAINS A DEFECT OR FAILS TO
COMPLY, THE NUMBER AND LOCATION OF ALL SUCH COMPONENTS IN USE AT,
SUPPLIED FOR, OR BEING SUPPLIED FOR ONE OR MORE FACILITIES OR
ACTIVITIES
SUBJECT TO THE REGULATIONS:
Ten (10) relays, P/N 7238908, were ordered. Four (4) were sent
to Houston Lighting & Power for installation in the South Texas
Project. Investigation has been initiated with Commonwealth
Edison and Houston Lighting & Power to determine the location
of the remaining six (6) relays.
Page 2
NOTIFICATION NO. CFRN 95-01
THE CORRECTIVE ACTION WHICH HAS, IS BEING, OR WILL BE TAKEN: THE NAME
OF
THE INDIVIDUAL OR ORGANIZATION RESPONSIBLE FOR THE ACTION: AND THE
LENGTH
OF TIME THAT HAS BEEN OR WILL BE TAKEN TO COMPLETE THE ACTION:
The effected component was produced under the quality program in
effect at Borg-Warner Nuclear Valve Division. In 1993, this product
line was transferred to the Pump Division. A Corrective Action
Request (CAR) has been issued for resolution by Pump Division
Quality Assurance. New equipment and part components are subject to
the approved quality program at this facility.
No further action is required.
ANY ADVICE RELATED TO THE DEFECT OF FAILURE TO COMPLY ABOUT THE
FACILITY,
ACTIVITY, OR BASIC COMPONENT THAT HAS BEEN, IS BEING, OR WILL BE GIVEN
TO
PURCHASERS:
BW/IP should be contacted for additional information.
Page 3
*** END OF DOCUMENT ***
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021