MR Number: H-03-0004

                           NRR DAILY REPORT ITEM
                           GENERIC COMMUNICATIONS



Subject: Issuance of Information Notice 2003-02

Information Notice 2003-02, Recent Experience With Reactor Coolant System
Leakage and Boric Acid Corrosion dated January 16, 2003                  
                                                                         
The U.S. Nuclear Regulatory Commission (NRC) is issuing this information 
notice to inform addressees of recently observed reactor coolant leakage 
at two pressurized water reactor facilities, one of which resulted in the
subsequent degradation of the reactor pressure vessel head.              
                                                                         
ADAMS Accession No.:  ML030160004                                        
                                                                         
Contacts:   V. Hodge, NRR               E. Sullivan, NRR                 
            301-415-1861                301-415-2796                     
            E-mail: cvh@nrc.gov         E-mail: ejs@nrc.gov  

            

PRIORITY ATTENTION REQUIRED  MORNING REPORT - REGION II  JANUARY 22, 2003

Licensee/Facility:                     Notification:

Virginia Power Co.                     MR Number: 2-03-0001
Surry 1                                Date: 01/22/03
Surry,Virginia                                                            
Dockets: 50-280
PWR/W-3-LP                            

Subject: SURRY UNIT 1 C REACTOR COOLANT PUMP MOTOR BEARING FAILURE       
                                                                         
Reportable Event Number: 39507                         

Discussion:

On 1/14/03 Surry Unit 1 was manually tripped from full power due to      
elevated C reactor coolant pump (RCP) shaft vibrations and a rapidly     
increasing lower motor bearing temperature.  The lower motor bearings    
revealed severe damage due to lack of lubrication.  Investigation        
revealed that the lower bearing oil reservoir site glass was empty and   
the reservoir was approximately 4 gallons below the 22 gallons required  
to fill the site glass to mid-scale.  The investigation also revealed    
that no oil low level alarm had been received due to a broken oil        
reservoir level switch assembly. Furthermore no adverse trend in the     
bearing RTD temperature had been noted.  The RTD was not installed in    
accordance with the Westinghouse drawing, in that, the RTD tip was not in
contact with the bearing shoe. The loss of oil apparently occurred       
through small leaks over the approximately 400 days the unit was in      
service.                                                                 
                                                                         
The licensee has inspected oil levels and functionally tested the level  
alarms for the other Unit 1 RCPs. The B RCP upper oil reservoir alarm    
failed and was repaired.  The C RCP motor bearing has been repaired and  
the unit is preparing for restart.                                       

Regional Action:

Routine resident followup.                                               

Contact:  L. GARNER                  (404)562-4552


 