Morning Report for April 22, 2002
Headquarters Daily Report APRIL 22, 2002 *************************************************************************** REPORT NEGATIVE NO INPUT ATTACHED INPUT RECEIVED RECEIVED HEADQUARTERS X REGION I X REGION II X REGION III X REGION IV X PRIORITY ATTENTION REQUIRED MORNING REPORT - REGION II APRIL 22, 2002 Licensee/Facility: Notification: Duke Power Co. MR Number: 2-02-0007 Oconee 1 Date: 04/22/02 Seneca,South Carolina Dockets: 50-269 PWR/B&W-L-LP Subject: SEVERED PLUGGED TUBE DISCOVERED IN STEAM GENERATOR Discussion: On April 15, 2002, the licensee informed the NRC that they had discovered a severed plugged tube in the 1B steam generator during outage inspections. Tube 78-124 was severed at the lower tube sheet. The licensee found the severed tube when an adjacent tube's plug was pulled for repair and wear scars were detected on it by eddy current examination. The licensee removed a section of the severed tube for metallurgical examination and root cause analysis. Regional Action: Under the guidance of NRC Management Directive 8.3, Region II initiated a Special Inspection on April 17, 2002. The location of the severed tube indicated that the failure mechanism was different than a recent severed tube at Three Mile Island 1, as described in NRC Information Notice 2002-02, Recent Experience With Plugged Steam Generator Tubes. The specific issue of concern to be addressed by the inspection is to obtain information so that the generic implications of the tube failure can be assessed. Contact: JEROME BLAKE (404)562-4607 _