PRIORITY ATTENTION REQUIRED  MORNING REPORT - HEADQUARTERS APRIL  5, 2002

MR Number: H-02-0026

                           NRR DAILY REPORT ITEM
                           GENERIC COMMUNICATIONS



Subject: Issuance of Information Notice 2002-13

NRC Information Notice 2002-13: Possible Indicators of Ongoing Reactor
Pressure Vessel Head Degradation dated April 4, 2002

The U.S. Nuclear Regulatory Commission is issuing this information notice
on recent Davis-Besse experience to alert addressees to possible
indicators of reactor coolant pressure boundary degradation including
degradation of the reactor vessel head material.

ADAMS Accession No.:  ML020930617

Technical Contacts: Ian Jung, NRR           John Jacobson, Region III
                    (301) 415-1837          (630) 829-9736
                    E-mail: ixj@nrc.gov     E-mail: jmj3@nrc.gov


 