Morning Report for February 1, 2002
Headquarters Daily Report
FEBRUARY 01, 2002
***************************************************************************
REPORT NEGATIVE NO INPUT
ATTACHED INPUT RECEIVED RECEIVED
HEADQUARTERS X
REGION I X
REGION II X
REGION III X
REGION IV X
PRIORITY ATTENTION REQUIRED MORNING REPORT - HEADQUARTERS FEB. 01, 2002
MR Number: H-02-0014
NRR DAILY REPORT ITEM
GENERIC COMMUNICATIONS
Subject: Issuance of Regulatory Issue Summary 2002-02
NRC Regulatory Issue Summary 2002-02: Lessons Learned Related to Recently
Submitted Decommissioning Plans and License Termination Plans dated
January 16, 2002
The U.S. Nuclear Regulatory Commission is issuing this regulatory issue
summary to inform addressees of lessons learned from reviews of recently
submitted decommissioning plans and license termination plans.
ADAMS Accession No.: ML013510432
Contact: Stewart W. Brown, NMSS
301-415-6605
E-mail: swb1@nrc.gov
_
HEADQUARTERS MORNING REPORT PAGE 2 FEBRUARY 1, 2002
MR Number: H-02-0015
NRR DAILY REPORT ITEM
GENERIC COMMUNICATIONS
Subject: Issuance of Information Notice 2002-07
NRC Information Notice 2002-07: Use of Sodium Hypochlorite for Cleaning
Diesel Fuel Oil Supply Tanks dated January 28, 2002
The U.S. Nuclear Regulatory Commission is issuing this information notice
to alert addressees to the potential problems related to the use of
sodium hypochlorite solutions for cleaning diesel fuel oil supply tanks.
Use of this chemical in higher concentrations can cause the release of
significant amounts of chlorine gas.
ADAMS Accession No.: ML013450182
Contacts: Krzysztof Parczewski, NRR M. Scott Freeman, Region II
301-415-2705 864-822-6927
E-mail: kip@nrc.gov E-mail: msf1@nrc.gov
_
HEADQUARTERS MORNING REPORT PAGE 3 FEBRUARY 1, 2002
MR Number: H-02-0016
NRR DAILY REPORT ITEM
GENERIC COMMUNICATIONS
Subject: Issuance of Information Notice 2002-08
NRC Information Notice 2002-08, Pump Shaft Damage Due to Excessive
Hardness of Shaft Sleeve dated January 30, 2002
The U.S. Nuclear Regulatory Commission is issuing this information notice
to alert addressees of potentially serious damage that occurred to pump
shafts manufactured by Bingham-Willamette. The damage resulted from
harder-than-specified material used during the manufacture of the thrust
sleeve installed on the pump shaft.
ADAMS Accession No.: ML020300002
Contacts: J. Melfi, Region IV B. Elliot, NRR
817-860-8269 301-415-2709
E-mail: jfm1@nrc.gov E-mail: bje@nrc.gov
W. Poertner, NRR
301-415-1175
E-mail: wkp@nrc.gov
_