The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Morning Report for October 13, 2000
Headquarters Daily Report
OCTOBER 13, 2000
***************************************************************************
REPORT NEGATIVE NO INPUT
ATTACHED INPUT RECEIVED RECEIVED
HEADQUARTERS X
REGION I X
REGION II X
REGION III X
REGION IV X
PRIORITY ATTENTION REQUIRED MORNING REPORT - REGION II OCTOBER 13, 2000
Licensee/Facility: Notification:
South Carolina Electric & Gas Co. MR Number: 2-00-0024
Summer 1 Date: 10/13/00
Jenkinsville,South Carolina
Dockets: 50-395
PWR/W-3-LP
Subject: CRACK IN WELD AREA OF REACTOR COOLANT SYSTEM (RCS)
Reportable Event Number: 37423
Discussion:
On October 7, 2000, Summer shut down the reactor for a scheduled
refueling outage. During a containment inspection, a large quantity of
boron was discovered on an RCS hot leg pipe at the primary shield wall
penetration. On October 12, when investigating the source of leakage, a
dye penetrant test revealed a 4-inch long circumferential, hairline crack
in the weld between the reactor vessel nozzle and the "A" hot leg piping
(29-inch inside diameter and 2 1/2-inch nominal thickness). The licensee
is continuing with their scheduled refueling outage activities, including
a full core offload. The licensee is evaluating repair strategies and
available vendors to accomplish the repair which will occur prior to
reloading fuel. Additional information is available in 10 CFR 50.72
notification (Event Number 37423).
Regional Action:
Region II plans to conduct a conference call with the licensee and
appropriate NRC personnel to discuss the licensee's continuing
investigation efforts and the repair plans. Region II plans to perform
followup inspection on this issue.
Contact: R. HAAG (404)562-4550
_
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021