Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Morning Report for November 12, 1999

                       Headquarters Daily Report

                         NOVEMBER 12, 1999

***************************************************************************
                    REPORT             NEGATIVE            NO INPUT
                    ATTACHED           INPUT RECEIVED      RECEIVED

HEADQUARTERS
REGION I                               X
REGION II                              X
REGION III          X
REGION IV                              X
PRIORITY ATTENTION REQUIRED  MORNING REPORT - HEADQUARTERS NOV. 12, 1999

MR Number: H-99-0098

                           NRR DAILY REPORT ITEM
                           GENERIC COMMUNICATIONS



Information Notice 99-30, "FAILURE OF DOUBLE CONTINGENCY BASED ON
ADMINISTRATIVE CONTROLS INVOLVING LABORATORY SAMPLING AND SPECTROSCOPIC
ANALYSIS OF WET URANIUM WASTE," was issued on November 8, 1999.

This notice was issued to all fuel cycle licensees and certificants
analyzing uranium content for criticality safety to alert them to
problems recently noted with laboratory and spectroscopic analysis. Under
certain conditions, incomplete dissolution of samples may produce a
nonconservative laboratory result and lead to violation of criticality
safety limits.

Contact:  Dennis C. Morey, NMSS
          301-415-6107
          E-mail: dcm@nrc.gov
_
REGION III  MORNING REPORT     PAGE  2          NOVEMBER 12, 1999

Licensee/Facility:                     Notification:

Michigan Electric Co.                  MR Number: 3-99-0091
Cook 2                                 Date: 11/12/99
Bridgman,Michigan                      RI VIA TELCON
Dockets: 50-316
PWR/W-4-LP

Subject: UNIT 2 ICE CONDENSER COOLDOWN

Discussion:

A controlled cooldown of the Unit 2 ice condenser was commenced at 9:40
a.m. on November 10, 1999. As of 8:00 a.m. on November 12, the average
ice condenser temperature had been reduced to approximately 55 degrees F.
The licensee plans to continue the cooldown to establish conditions for
condenser ice reload. The commencement of ice condenser restoration
activities marks a significant milestone in the licensee's efforts to
restart Unit 2.

The licensee melted the ice in the Unit 2 ice condenser during the summer
of 1998 to allow unrestricted access to condenser ice baskets for
inspection and repair work (see Preliminary Notification PN-III-98-028).
The function of the ice condenser system is to condense steam released
into the reactor containment, in the event of a loss-of-coolant accident,
to reduce the pressure and avoid damage to containment structures.

Regional Action:

Resident and Region based Inspectors are conducting oversight inspections
of ice condenser restoration activities.

Contact:  A. VEGEL                   (630)829-9620