Morning Report for May 21, 1999
Headquarters Daily Report
MAY 21, 1999
***************************************************************************
REPORT NEGATIVE NO INPUT
ATTACHED INPUT RECEIVED RECEIVED
HEADQUARTERS X
REGION I X
REGION II X
REGION III X
REGION IV X
PRIORITY ATTENTION REQUIRED MORNING REPORT - HEADQUARTERS MAY 21, 1999
Licensee/Facility: Notification:
MR Number: H-99-0045
Proposed Generic Communication Date: 05/21/99
Subject: Proposed Information Notice
Discussion:
The U.S. Nuclear Regulatory Commission intends to issue an information
notice discussing the May 14, 1999, manual reactor trip at Point Beach
Unit 1. The manual trip was in response to the occurrence of a steam leak
on the number 4B feedwater heater. The steam leak resulted when the
number feedwater heater shell ruptured.
Contact: E. Nick Fields, NRR
(301) 415-1173
Email: enf@nrc.gov
_
REGION III MORNING REPORT PAGE 2 MAY 21, 1999
Licensee/Facility: Notification:
Commonwealth Edison Co. MR Number: 3-99-0046
Braidwood 2 Date: 05/21/99
Braceville,Illinois SRI via e-mail
Dockets: 50-457
PWR/W-4-LP
Subject: UNIT 2 STARTUP FROM REFUELING OUTAGE
Discussion:
Unit 2 was returned to service from refueling outage A2R07. The unit was
made critical at 3:30 p.m. and synchronized to the electrical grid at
6:21 p.m. on May 20, 1999. Major work accomplished during the outage
included a modification to the 2B Emergency Diesel Generator electronic
governor, a modification to the auxiliary feedwater flow control valve
trim, and repairs to a pressurizer spray valve.
Regional Action:
None.
Contact: Michael Jordan (630)829-9637
_
REGION III MORNING REPORT PAGE 3 MAY 21, 1999
Licensee/Facility: Notification:
Detroit Edison Co. MR Number: 3-99-0047
Fermi 2 Date: 05/21/99
Newport,Michigan SRI via telecon
Dockets: 50-341
BWR/GE-4
Subject: FERMI STARTUP FOLLOWING FORCED OUTAGE
Discussion:
The Fermi 2 nuclear plant was taken critical at 1:27 p.m. on May 20,
1999, and the main generator was synchronized to the grid at 6:40 a.m. on
May 21, 1999, following a forced outage. The forced outage began on May
18, 1999, when the operators manually scrammed the reactor in response to
the trip of the "A" reactor recirculating pump which placed the reactor
in a prohibited region of the Technical Specification power to flow map.
Regional Action:
The resident inspectors monitored the startup activities.
Contact: Anton Vegel (630)829-9620
_