Morning Report for April 19, 1999
Headquarters Daily Report APRIL 19, 1999 *************************************************************************** REPORT NEGATIVE NO INPUT ATTACHED INPUT RECEIVED RECEIVED HEADQUARTERS X REGION I X REGION II X REGION III X REGION IV X PRIORITY ATTENTION REQUIRED MORNING REPORT - REGION III APRIL 19, 1999 Licensee/Facility: Notification: Northern States Power Co. MR Number: 3-99-0030 Prairie Island 1 Date: 04/16/99 Welch,Minnesota E-mail - Resident Inspector Office Dockets: 50-282 PWR/W-2-LP Subject: UNIT 1 REFUELING OUTAGE Discussion: Prairie Island Unit 1 began its cycle 20 refueling outage on April 17, 1999. The outage is planned for 42 days with return to full power operation planned for May 31. Major activities for the outage include steam generator eddy current inspections, steam generator primary manway and bolt hole repairs, a full-core fuel offload to support incore monitoring thimble tube replacement, '1M' auxiliary transformer replacement, and removal of the Unit 1 part-length control rod drive mechanisms (CRDMs) and capping of the housings. The transformer is being replaced because it catastrophically failed on January 5, 1999. The part-length CRDMs are being removed because a Unit 2 part-length CRDM developed an unisolable leak in February 1998. In addition, during the outage, on May 1, an open-house will be held as part of the 25th anniversary celebration for Unit 1 and will allow members of the local community to tour selected areas of Unit 1. Regional Action: The resident inspectors observed the reactor shutdown from the control room and will review selected operations and maintenance activities during the outage. Contact: Roger Lanksbury (630)829-9631 _ REGION III MORNING REPORT PAGE 2 APRIL 19, 1999 Licensee/Facility: Notification: Abb-Combustion Engineering, Inc. MR Number: 3-99-0031 Hematite Facility Date: 04/19/99 Festus,Missouri telephone Dockets: 07000036 Subject: Site Management Changes Discussion: Effective May 1, 1999, Mr. Gilles Page will succeed Dr. Bruce Kaiser as the Vice President, Nuclear Fuels, at the ABB-CE Hematite and Windsor Facilities. Mr. Page has been with the ABB-CE Nuclear Power organization since 1985 and is currently the Director of Operations at the Hematite and Windsor Facilities. No announcement regarding a successor for the Director of Operations position at the Hematite and Windsor Facilities has been made at this time. Regional Action: None Contact: Robert G. Krsek (630)829-9843 _
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021