Event Notification Report for August 24, 2026
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
08/23/2026 - 08/24/2026
Agreement State
Event Number: 58410
Rep Org: NC Div of Radiation Protection
Licensee: Unknown
Region: 1
City: Rocky Mount State: NC
County:
License #: Unknown
Agreement: Y
Docket:
NRC Notified By: James D. Albright
HQ OPS Officer: Sebastien Bruneau
Licensee: Unknown
Region: 1
City: Rocky Mount State: NC
County:
License #: Unknown
Agreement: Y
Docket:
NRC Notified By: James D. Albright
HQ OPS Officer: Sebastien Bruneau
Notification Date: 08/13/2026
Notification Time: 23:46 [ET]
Event Date: 08/13/2026
Event Time: 00:00 [EDT]
Last Update Date: 08/14/2026
Notification Time: 23:46 [ET]
Event Date: 08/13/2026
Event Time: 00:00 [EDT]
Last Update Date: 08/14/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
NMSS_EVENTS_NOTIFICATION (EMAIL)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - FOUND SOURCE
The following is a summary of information provided by the North Carolina Department of Health and Human Services, Radioactive Materials Branch (NCRAM) via phone and email:
The Florida Department of Health, Bureau of Radiation Control (FLBRC) responded to a call from the public and impounded 2 lead pigs possessed by a Florida resident. One lead pig held an estimated 50 mCi Ra-226 nasopharyngeal radium applicator with a 25 R/hr on contact dose rate. The second pig was empty. FLBRC determined that the lead pigs originated from a residence located in Rocky Mount, NC, owned by the family of the Florida resident. FLBRC informed NCRAM of the missing Ra-226 source. NCRAM located the second source, unshielded, in the garage of the North Carolina residence. The source in North Carolina was removed from the residence and is currently secured at NCRAM.
NCRAM reports dose rates of 400 mR/hr at 30 cm, and 50 mR/hr at 1 meter, for the found Ra-226 source. Exposures to members of the public are unknown, and the licensee is unknown.
An NMED written report will follow. All data is confirmed but preliminary.
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following is a summary of information provided by the North Carolina Department of Health and Human Services, Radioactive Materials Branch (NCRAM) via phone and email:
The Florida Department of Health, Bureau of Radiation Control (FLBRC) responded to a call from the public and impounded 2 lead pigs possessed by a Florida resident. One lead pig held an estimated 50 mCi Ra-226 nasopharyngeal radium applicator with a 25 R/hr on contact dose rate. The second pig was empty. FLBRC determined that the lead pigs originated from a residence located in Rocky Mount, NC, owned by the family of the Florida resident. FLBRC informed NCRAM of the missing Ra-226 source. NCRAM located the second source, unshielded, in the garage of the North Carolina residence. The source in North Carolina was removed from the residence and is currently secured at NCRAM.
NCRAM reports dose rates of 400 mR/hr at 30 cm, and 50 mR/hr at 1 meter, for the found Ra-226 source. Exposures to members of the public are unknown, and the licensee is unknown.
An NMED written report will follow. All data is confirmed but preliminary.
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 58411
Rep Org: Arizona Dept of Health Services
Licensee: Banner Desert Medical Center
Region: 4
City: Mesa State: AZ
County:
License #: 07-176
Agreement: Y
Docket:
NRC Notified By: Brian D. Goretzki
HQ OPS Officer: Karen Cotton
Licensee: Banner Desert Medical Center
Region: 4
City: Mesa State: AZ
County:
License #: 07-176
Agreement: Y
Docket:
NRC Notified By: Brian D. Goretzki
HQ OPS Officer: Karen Cotton
Notification Date: 08/14/2026
Notification Time: 19:47 [ET]
Event Date: 08/14/2026
Event Time: 00:00 [MST]
Last Update Date: 08/14/2026
Notification Time: 19:47 [ET]
Event Date: 08/14/2026
Event Time: 00:00 [MST]
Last Update Date: 08/14/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
NMSS_EVENTS_NOTIFICATION (EMAIL)
Christian Einberg (MSEB BC)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Christian Einberg (MSEB BC)
AGREEMENT STATE REPORT - MEDICAL EVENT
The following information was provided by the Arizona Department of Health Services (the Department) via email:
"The Department received notification from Banner Desert Medical Center regarding a medical event involving a two-month-old patient that occurred on August 14, 2026. The patient was prescribed 1 millicurie of technetium-99m (Tc-99m) for a renal scan, however, the patient was inadvertently administered 30 millicuries of Tc-99m for a bone scan. Following the event, the licensee performed a dose assessment and estimated that the administered activity resulted in an absorbed dose of approximately 22 Gy to the bone and 15 Gy to the bladder wall. The Department continues to investigate the event.
"Additional information will be provided as it is received in accordance with SA-300."
Arizona incident: 26-047
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
The following information was provided by the Arizona Department of Health Services (the Department) via email:
"The Department received notification from Banner Desert Medical Center regarding a medical event involving a two-month-old patient that occurred on August 14, 2026. The patient was prescribed 1 millicurie of technetium-99m (Tc-99m) for a renal scan, however, the patient was inadvertently administered 30 millicuries of Tc-99m for a bone scan. Following the event, the licensee performed a dose assessment and estimated that the administered activity resulted in an absorbed dose of approximately 22 Gy to the bone and 15 Gy to the bladder wall. The Department continues to investigate the event.
"Additional information will be provided as it is received in accordance with SA-300."
Arizona incident: 26-047
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
Part 21
Event Number: 58415
Rep Org: Vogtle
Licensee:
Region: 2
City: Waynesboro State: GA
County:
License #:
Agreement: Y
Docket:
NRC Notified By: Cathy Galloway
HQ OPS Officer: Sam Colvard
Licensee:
Region: 2
City: Waynesboro State: GA
County:
License #:
Agreement: Y
Docket:
NRC Notified By: Cathy Galloway
HQ OPS Officer: Sam Colvard
Notification Date: 08/21/2026
Notification Time: 17:05 [ET]
Event Date: 08/21/2026
Event Time: 00:00 [EDT]
Last Update Date: 08/21/2026
Notification Time: 17:05 [ET]
Event Date: 08/21/2026
Event Time: 00:00 [EDT]
Last Update Date: 08/21/2026
Emergency Class: Non Emergency
10 CFR Section:
21.21(d)(3)(i) - Defects And Noncompliance
10 CFR Section:
21.21(d)(3)(i) - Defects And Noncompliance
Person (Organization):
Part 21/50.55 Reactors, - (EMAIL)
R2_Reactor_Event (EMAIL)
Part 21/50.55 Reactors, - (EMAIL)
R2_Reactor_Event (EMAIL)
PART 21 - RELAY DEVIATION
The following information was provided by the licensee via email:
"Initial 10 CFR 21 Notification - Defect Associated with GE Vernova Hitachi Overvoltage and Undervoltage Protection Relay, Part Number DD304A3853P001
"This is a non-emergency initial notification pursuant to 10 CFR 21.21(d)(3)(i). A written report containing the information required by 10 CFR 21.21(d)(4) will be submitted in accordance with 10 CFR 21.21(d)(3)(ii).
"GE Vernova Hitachi (GVH) identified a deviation in the commercial-grade dedication testing of overvoltage and undervoltage protection relays, GVH part number DD304A3853P001 and manufacturer part number 12IAV53K1A. The dedication process required testing of both seal-in units; however, GVH determined that only one of the two seal-in units had historically been included in the testing scope.
"Southern Nuclear Operating Company's (SNC) evaluation determined that the deviation could create a substantial safety hazard if an affected relay intended for use at the Vogtle Electric Generating Plant (Vogtle) were installed and left uncorrected. Failure of an affected relay could impact equipment relied upon to support the security system. SNC has verified that no affected relay is installed or in service at Vogtle. The affected relays in SNC's possession have been removed from available inventory and will not be installed without appropriate disposition.
"The NRC Senior Resident Inspectors have been notified."
Point of Contact:
Kari Osborne, Lead Engineer, SNC
Phone: 205-992-5256
Email: kosborne@southernco.com
The following information was provided by the licensee via email:
"Initial 10 CFR 21 Notification - Defect Associated with GE Vernova Hitachi Overvoltage and Undervoltage Protection Relay, Part Number DD304A3853P001
"This is a non-emergency initial notification pursuant to 10 CFR 21.21(d)(3)(i). A written report containing the information required by 10 CFR 21.21(d)(4) will be submitted in accordance with 10 CFR 21.21(d)(3)(ii).
"GE Vernova Hitachi (GVH) identified a deviation in the commercial-grade dedication testing of overvoltage and undervoltage protection relays, GVH part number DD304A3853P001 and manufacturer part number 12IAV53K1A. The dedication process required testing of both seal-in units; however, GVH determined that only one of the two seal-in units had historically been included in the testing scope.
"Southern Nuclear Operating Company's (SNC) evaluation determined that the deviation could create a substantial safety hazard if an affected relay intended for use at the Vogtle Electric Generating Plant (Vogtle) were installed and left uncorrected. Failure of an affected relay could impact equipment relied upon to support the security system. SNC has verified that no affected relay is installed or in service at Vogtle. The affected relays in SNC's possession have been removed from available inventory and will not be installed without appropriate disposition.
"The NRC Senior Resident Inspectors have been notified."
Point of Contact:
Kari Osborne, Lead Engineer, SNC
Phone: 205-992-5256
Email: kosborne@southernco.com