Event Notification Report for August 13, 2026
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
08/12/2026 - 08/13/2026
Agreement State
Event Number: 58396
Rep Org: Florida Bureau of Radiation Control
Licensee: Sarasota Memorial Hospital
Region: 1
City: Sarasota State: FL
County:
License #: 111-3
Agreement: Y
Docket:
NRC Notified By: John Williamson
HQ OPS Officer: Kerby Scales
Licensee: Sarasota Memorial Hospital
Region: 1
City: Sarasota State: FL
County:
License #: 111-3
Agreement: Y
Docket:
NRC Notified By: John Williamson
HQ OPS Officer: Kerby Scales
Notification Date: 08/05/2026
Notification Time: 12:37 [ET]
Event Date: 07/30/2026
Event Time: 00:00 [EDT]
Last Update Date: 08/05/2026
Notification Time: 12:37 [ET]
Event Date: 07/30/2026
Event Time: 00:00 [EDT]
Last Update Date: 08/05/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Bickett, Brice (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Bickett, Brice (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - MEDICAL EVENT
The following is a summary of information provided by the Florida Bureau of Radiation Control (BRC) via email:
On July 30, 2026, a 76-year-old patient was undergoing treatment with Y-90 Theraspheres. The prescribed liver dose was 151 Gy, but only 24.1 Gy (15.96 percent) was actually delivered due to a partial kink in the catheter attached to the delivery tube. Both the patient and the treating physician have been informed. The treating physician will reevaluate the patient in one month. The incident has been reported to the radioactive material licensing section for further action.
Florida Incident Number: FL26-066
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
The following is a summary of information provided by the Florida Bureau of Radiation Control (BRC) via email:
On July 30, 2026, a 76-year-old patient was undergoing treatment with Y-90 Theraspheres. The prescribed liver dose was 151 Gy, but only 24.1 Gy (15.96 percent) was actually delivered due to a partial kink in the catheter attached to the delivery tube. Both the patient and the treating physician have been informed. The treating physician will reevaluate the patient in one month. The incident has been reported to the radioactive material licensing section for further action.
Florida Incident Number: FL26-066
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
Non-Agreement State
Event Number: 58398
Rep Org: US Army
Licensee: US Army
Region: 4
City: Fairbanks State: AK
County:
License #: 21-32838-01
Agreement: N
Docket:
NRC Notified By: Nathan Krzyaniak
HQ OPS Officer: Josue Ramirez
Licensee: US Army
Region: 4
City: Fairbanks State: AK
County:
License #: 21-32838-01
Agreement: N
Docket:
NRC Notified By: Nathan Krzyaniak
HQ OPS Officer: Josue Ramirez
Notification Date: 08/06/2026
Notification Time: 15:21 [ET]
Event Date: 08/05/2026
Event Time: 00:00 [YDT]
Last Update Date: 08/06/2026
Notification Time: 15:21 [ET]
Event Date: 08/05/2026
Event Time: 00:00 [YDT]
Last Update Date: 08/06/2026
Emergency Class: Non Emergency
10 CFR Section:
20.2201(a)(1)(i) - Lost/Stolen LNM>1000x
10 CFR Section:
20.2201(a)(1)(i) - Lost/Stolen LNM>1000x
Person (Organization):
Sanchez Santiago, Elba (R3DO)
Young, Cale (R4DO)
NMSS_Events_Notification, (EMAIL)
Sanchez Santiago, Elba (R3DO)
Young, Cale (R4DO)
NMSS_Events_Notification, (EMAIL)
LOST AND FOUND SOURCE
The following is a summary of information provided by the licensee via phone:
On August 6, 2026, at 1255 EDT, the licensee's radiation safety officer was notified of a found source near Fort Wainwright, Alaska. On August 5, 2026, a member of the public found an M67 sight-unit at a local disposal/transfer site. The total activity for the source is 5.79 Ci of tritium. The source appeared to be intact and wipe samples were taken. There were no indications of personnel exposures. The source is currently with Fort Wainwright Police. It is unknown when the source went missing but the licensee will conduct an investigation.
The following is a summary of information provided by the licensee via phone:
On August 6, 2026, at 1255 EDT, the licensee's radiation safety officer was notified of a found source near Fort Wainwright, Alaska. On August 5, 2026, a member of the public found an M67 sight-unit at a local disposal/transfer site. The total activity for the source is 5.79 Ci of tritium. The source appeared to be intact and wipe samples were taken. There were no indications of personnel exposures. The source is currently with Fort Wainwright Police. It is unknown when the source went missing but the licensee will conduct an investigation.
Agreement State
Event Number: 58399
Rep Org: Texas Dept of State Health Services
Licensee: Phillips 66 Sweeny Refinery
Region: 4
City: Old Ocean State: TX
County:
License #: L06524
Agreement: Y
Docket:
NRC Notified By: Sindiso Ncube
HQ OPS Officer: Kerby Scales
Licensee: Phillips 66 Sweeny Refinery
Region: 4
City: Old Ocean State: TX
County:
License #: L06524
Agreement: Y
Docket:
NRC Notified By: Sindiso Ncube
HQ OPS Officer: Kerby Scales
Notification Date: 08/06/2026
Notification Time: 18:54 [ET]
Event Date: 08/05/2026
Event Time: 00:00 [CDT]
Last Update Date: 08/06/2026
Notification Time: 18:54 [ET]
Event Date: 08/05/2026
Event Time: 00:00 [CDT]
Last Update Date: 08/06/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Young, Cale (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Young, Cale (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - DAMAGED SOURCE HOLDER
The following information was provided by the Texas Department of State Health Services (the Agency) via phone and email:
"On August 6, 2026, the Agency received notification from the licensee regarding a source holder not operating as designed. The licensee reported that the source holder, a Vega model SHLG-3, contains an 8000 millicurie cesium-137 sealed source. On August 5, 2026, the licensee discovered that when the source shutter is in the open or operational position, radiation survey readings at the top of the shutter show normal exposure rates of around 2 milliroentgens per hour (mR/hr) at 1 foot. However, when the shutter is in the closed or shielded position, radiation readings at the top of the shutter are elevated and show exposure rates of around 375 mR/hr at 1 foot. The licensee reported that there is no risk of additional radiation exposure to members of the public or radiation workers when the on/off mechanism is in the open position. The licensee has contacted Vega to repair the unit."
Texas Incident Number: 10315
The following information was provided by the Texas Department of State Health Services (the Agency) via phone and email:
"On August 6, 2026, the Agency received notification from the licensee regarding a source holder not operating as designed. The licensee reported that the source holder, a Vega model SHLG-3, contains an 8000 millicurie cesium-137 sealed source. On August 5, 2026, the licensee discovered that when the source shutter is in the open or operational position, radiation survey readings at the top of the shutter show normal exposure rates of around 2 milliroentgens per hour (mR/hr) at 1 foot. However, when the shutter is in the closed or shielded position, radiation readings at the top of the shutter are elevated and show exposure rates of around 375 mR/hr at 1 foot. The licensee reported that there is no risk of additional radiation exposure to members of the public or radiation workers when the on/off mechanism is in the open position. The licensee has contacted Vega to repair the unit."
Texas Incident Number: 10315