Event Notification Report for August 05, 2026
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
08/04/2026 - 08/05/2026
Agreement State
Event Number: 58384
Rep Org: Colorado Dept of Health
Licensee: LDS Church
Region: 4
City: Loveland State: CO
County:
License #: GL001135
Agreement: Y
Docket:
NRC Notified By: Kathryn Kirk
HQ OPS Officer: Brian P. Smith
Licensee: LDS Church
Region: 4
City: Loveland State: CO
County:
License #: GL001135
Agreement: Y
Docket:
NRC Notified By: Kathryn Kirk
HQ OPS Officer: Brian P. Smith
Notification Date: 07/28/2026
Notification Time: 16:09 [ET]
Event Date: 12/19/2024
Event Time: 00:00 [MDT]
Last Update Date: 07/28/2026
Notification Time: 16:09 [ET]
Event Date: 12/19/2024
Event Time: 00:00 [MDT]
Last Update Date: 07/28/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
AGREEMENT STATE REPORT - LOST EXIT SIGNS
The following is a summary of information provided by the Colorado Department of Public Health and Environment via email:
Two exit signs were declared lost by the licensee on December 19, 2024. The exit signs are model number BR-20-BK manufactured by SRB Technologies and have an H3 (tritium) source of 17.51 Ci each.
Colorado Event Number: CO260015
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following is a summary of information provided by the Colorado Department of Public Health and Environment via email:
Two exit signs were declared lost by the licensee on December 19, 2024. The exit signs are model number BR-20-BK manufactured by SRB Technologies and have an H3 (tritium) source of 17.51 Ci each.
Colorado Event Number: CO260015
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 58385
Rep Org: California Radiation Control Prgm
Licensee: Loma Linda University
Region: 4
City: San Bernardino State: CA
County:
License #: 0060-36
Agreement: Y
Docket:
NRC Notified By: Donald Oesterle
HQ OPS Officer: Brian P. Smith
Licensee: Loma Linda University
Region: 4
City: San Bernardino State: CA
County:
License #: 0060-36
Agreement: Y
Docket:
NRC Notified By: Donald Oesterle
HQ OPS Officer: Brian P. Smith
Notification Date: 07/28/2026
Notification Time: 20:04 [ET]
Event Date: 07/24/2026
Event Time: 00:00 [PDT]
Last Update Date: 07/28/2026
Notification Time: 20:04 [ET]
Event Date: 07/24/2026
Event Time: 00:00 [PDT]
Last Update Date: 07/28/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - MEDICAL EVENT
The following information was provided by the California Radiation Control Program (the Program) via email:
"The Program was notified on July 28, 2026, that a reportable medial event had occurred on July 24, 2026, at the Loma Linda University Medical Center. The authorized user had prescribed Y-90 Theraspheres, distributed by Boston Scientific Corp. and produced by BWXT Medical Ltd. with a dose to the target (segment 8 of liver) of 570 Gy. The delivery of the dose to the patient seemed to be uneventful. Initial radiation surveys of the patient, the operating room, and the waste container were reported as within normal limits. Nuclear medicine initially reported that 98 percent of the dose was delivered to the patient.
"However, the patient's post-treatment single-photon emission computed tomography (SPECT) imaging indicated very low activity was found in the patient's liver. A review of the nuclear medicine processes determined that the waste container with the microcatheter was actually radioactive. The initial measurements recorded by the certified nuclear medicine technologist were erroneously recorded as microrem per hour instead of millirem per hour. A second SPECT image was taken of the patient and calculations indicated that 7 percent of the dose was received by the patient, which qualifies as a medical event under 10 CFR 35. 3045. A Boston Scientific representative was present during the administration. He has arranged for the delivery system to be evaluated by the manufacturer once the radiation levels are decayed. The Program will follow-up with the licensee during this investigation."
California 5010 Event Number: 072426
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
The following information was provided by the California Radiation Control Program (the Program) via email:
"The Program was notified on July 28, 2026, that a reportable medial event had occurred on July 24, 2026, at the Loma Linda University Medical Center. The authorized user had prescribed Y-90 Theraspheres, distributed by Boston Scientific Corp. and produced by BWXT Medical Ltd. with a dose to the target (segment 8 of liver) of 570 Gy. The delivery of the dose to the patient seemed to be uneventful. Initial radiation surveys of the patient, the operating room, and the waste container were reported as within normal limits. Nuclear medicine initially reported that 98 percent of the dose was delivered to the patient.
"However, the patient's post-treatment single-photon emission computed tomography (SPECT) imaging indicated very low activity was found in the patient's liver. A review of the nuclear medicine processes determined that the waste container with the microcatheter was actually radioactive. The initial measurements recorded by the certified nuclear medicine technologist were erroneously recorded as microrem per hour instead of millirem per hour. A second SPECT image was taken of the patient and calculations indicated that 7 percent of the dose was received by the patient, which qualifies as a medical event under 10 CFR 35. 3045. A Boston Scientific representative was present during the administration. He has arranged for the delivery system to be evaluated by the manufacturer once the radiation levels are decayed. The Program will follow-up with the licensee during this investigation."
California 5010 Event Number: 072426
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
Power Reactor
Event Number: 58392
Facility: Millstone
Region: 1 State: CT
Unit: [2] [] []
RX Type: [1] GE-3,[2] CE,[3] W-4-LP
NRC Notified By: Zach Hiett
HQ OPS Officer: Karen Cotton
Region: 1 State: CT
Unit: [2] [] []
RX Type: [1] GE-3,[2] CE,[3] W-4-LP
NRC Notified By: Zach Hiett
HQ OPS Officer: Karen Cotton
Notification Date: 08/03/2026
Notification Time: 16:21 [ET]
Event Date: 08/03/2026
Event Time: 14:20 [EDT]
Last Update Date: 08/03/2026
Notification Time: 16:21 [ET]
Event Date: 08/03/2026
Event Time: 14:20 [EDT]
Last Update Date: 08/03/2026
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical
Person (Organization):
Haney, Sherlyn (R1DO)
Haney, Sherlyn (R1DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | M/R | Y | 100 | Power Operation | 0 | Hot Standby |
MANUAL REACTOR TRIP
The following information was provided by the licensee via phone and email:
"On August 3, 2026, at 1420 EDT, with Millstone Unit 2 operating in Mode 1 at approximately 100 percent power, operators manually tripped the reactor following an 'A' steam generator feedwater pump trip. The reactor trip was uncomplicated, and all plant systems responded as expected. Operations responded and stabilized the plant. The auxiliary feedwater system automatically actuated as designed following the reactor trip and provided feedwater to the steam generators. Decay heat removal is being maintained by the main steam system.
"This event is reported pursuant to 10 CFR 50. 72(b)(2)(iv)(B) as a four-hour, non-emergency notification due to the actuation of the reactor protection system while the reactor was critical.
"There was no impact on Unit 3. No radiological releases occurred as a result of this event, and there was no impact on the health and safety of the public or station personnel.
"The NRC Resident Inspector has been notified. "
The following information was provided by the licensee via phone and email:
"On August 3, 2026, at 1420 EDT, with Millstone Unit 2 operating in Mode 1 at approximately 100 percent power, operators manually tripped the reactor following an 'A' steam generator feedwater pump trip. The reactor trip was uncomplicated, and all plant systems responded as expected. Operations responded and stabilized the plant. The auxiliary feedwater system automatically actuated as designed following the reactor trip and provided feedwater to the steam generators. Decay heat removal is being maintained by the main steam system.
"This event is reported pursuant to 10 CFR 50. 72(b)(2)(iv)(B) as a four-hour, non-emergency notification due to the actuation of the reactor protection system while the reactor was critical.
"There was no impact on Unit 3. No radiological releases occurred as a result of this event, and there was no impact on the health and safety of the public or station personnel.
"The NRC Resident Inspector has been notified. "
Non-Agreement State
Event Number: 58387
Rep Org: Curium
Licensee: Curium
Region: 3
City: Noblesville State: IN
County:
License #: 1-3-35179-02
Agreement: N
Docket:
NRC Notified By: Manuel Diaz
HQ OPS Officer: Karen Cotton
Licensee: Curium
Region: 3
City: Noblesville State: IN
County:
License #: 1-3-35179-02
Agreement: N
Docket:
NRC Notified By: Manuel Diaz
HQ OPS Officer: Karen Cotton
Notification Date: 07/29/2026
Notification Time: 11:13 [ET]
Event Date: 07/28/2026
Event Time: 07:51 [EDT]
Last Update Date: 07/29/2026
Notification Time: 11:13 [ET]
Event Date: 07/28/2026
Event Time: 07:51 [EDT]
Last Update Date: 07/29/2026
Emergency Class: Non Emergency
10 CFR Section:
30.50(b)(1) - Unplanned Contamination
10 CFR Section:
30.50(b)(1) - Unplanned Contamination
Person (Organization):
Sanchez Santiago, Elba (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Sanchez Santiago, Elba (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
UNPLANNED CONTAMINATION
The following information was provided by the licensee via phone and email:
"On July 28, 2026, at approximately 0751 EDT during the production activities of Sr-82, a pressurized line used for argon burst inside the production hot cell. The burst resulted in the hot cell to be temporarily positively pressurized releasing radioactive material outside of the hot cell. Three operators that were part of the production activities became internally and externally contaminated. An additional operator that was not part of the production activities but assisted when the burst was escalated to the production manager also was internally and externally contaminated. The operators were unaware of the contamination and continued working for approximately 1.2 hours. One operator found contamination when performing a whole-body scan after donning his personal protective equipment (PPE) and exiting the production area. The operator alerted a radiation safety technician at 0922.
"The radiation safety technician communicated the incident to the principal health physicist (who was acting as the radiation safety officer (RSO)) at 0930. The principal health physicist communicated the incident to the director of the RSO at 1017. The director of the RSO immediately initiated a stop work. The principal health physicist communicated the stop work to production personnel and removed them from the production area. The principal health physicist, health physicist, and radiation safety technician performed contamination surveys of the affected individuals, collected air samples in the affected area, collected large area wipes, decontaminated the affected individuals and collected bioassay samples to estimate external and internal doses. The derived airborne concentration (DAC) in the affected area was measured to be 1.02E-08 microcuries/mL for Sr-82. The [10 CFR Part 20, Appendix B, Table 1 value for] DAC for Sr-82 is 2E-07 microcuries/mL. Health Physics also performed large area wipes of the affected area and estimated the total activity release to be approximately 135 mCi (July 29th at 1053).
"Immediately after the total activity was estimated, the principal health physicist communicated the results to the RSO. The principal health physicist and RSO called the NRC Operations Center to report the event under 10 CFR 30.50(b)(1). At the time of this report, the occupational doses for the affected operators have not been completed. Based on area air samples, the total internal dose is expected to be approximately 1 mrem. The expected shallow-dose equivalent (SDE) to the whole-body is estimated to be 3.4 rem. The total intake, committed dose equivalent (CDE), committed effective dose equivalent (CEDE), and total effective dose equivalent (TEDE) will be estimated from the bioassay samples and additional count rate measurements.
"The affected area is access controlled using normal badging system and isolated. Health Physics implemented additional PPE requirements with a third layer of shoe covers and is initiating the decontamination of the area."
The following information was provided by the licensee via phone and email:
"On July 28, 2026, at approximately 0751 EDT during the production activities of Sr-82, a pressurized line used for argon burst inside the production hot cell. The burst resulted in the hot cell to be temporarily positively pressurized releasing radioactive material outside of the hot cell. Three operators that were part of the production activities became internally and externally contaminated. An additional operator that was not part of the production activities but assisted when the burst was escalated to the production manager also was internally and externally contaminated. The operators were unaware of the contamination and continued working for approximately 1.2 hours. One operator found contamination when performing a whole-body scan after donning his personal protective equipment (PPE) and exiting the production area. The operator alerted a radiation safety technician at 0922.
"The radiation safety technician communicated the incident to the principal health physicist (who was acting as the radiation safety officer (RSO)) at 0930. The principal health physicist communicated the incident to the director of the RSO at 1017. The director of the RSO immediately initiated a stop work. The principal health physicist communicated the stop work to production personnel and removed them from the production area. The principal health physicist, health physicist, and radiation safety technician performed contamination surveys of the affected individuals, collected air samples in the affected area, collected large area wipes, decontaminated the affected individuals and collected bioassay samples to estimate external and internal doses. The derived airborne concentration (DAC) in the affected area was measured to be 1.02E-08 microcuries/mL for Sr-82. The [10 CFR Part 20, Appendix B, Table 1 value for] DAC for Sr-82 is 2E-07 microcuries/mL. Health Physics also performed large area wipes of the affected area and estimated the total activity release to be approximately 135 mCi (July 29th at 1053).
"Immediately after the total activity was estimated, the principal health physicist communicated the results to the RSO. The principal health physicist and RSO called the NRC Operations Center to report the event under 10 CFR 30.50(b)(1). At the time of this report, the occupational doses for the affected operators have not been completed. Based on area air samples, the total internal dose is expected to be approximately 1 mrem. The expected shallow-dose equivalent (SDE) to the whole-body is estimated to be 3.4 rem. The total intake, committed dose equivalent (CDE), committed effective dose equivalent (CEDE), and total effective dose equivalent (TEDE) will be estimated from the bioassay samples and additional count rate measurements.
"The affected area is access controlled using normal badging system and isolated. Health Physics implemented additional PPE requirements with a third layer of shoe covers and is initiating the decontamination of the area."