Event Notification Report for July 07, 2026

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
07/06/2026 - 07/07/2026

EVENT NUMBERS
5833958340
Agreement State
Event Number: 58339
Rep Org: Illinois Emergency Mgmt. Agency
Licensee: Radiopharmacy of Indianapolis
Region: 3
City: Glen Ellyn   State: IL
County: DuPage
License #:
Agreement: Y
Docket:
NRC Notified By: Kimberly Stice
HQ OPS Officer: Sebastien Bruneau
Notification Date: 06/29/2026
Notification Time: 15:01 [ET]
Event Date: 06/24/2026
Event Time: 00:00 [CDT]
Last Update Date: 06/29/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Betancourt-Roldan, Diana (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - FOUND GENERATOR

The following information was provided by the Illinois Emergency Management Agency (the Agency) via phone and email:

"On June 24, 2026, the Agency was notified by the Addison Fire Department that a number of Mo-99/Tc-99m generators were found within a storage unit in Glen Ellyn. Radioactive material inspectors responded within the hour and observed three packages containing Mo-99/Tc-99m generators originating from October 2024. Inspectors conducted surveys, examined shipment labels and paperwork, and confirmed that the generators no longer represented a radiological hazard. The generators were transported to the West Chicago office and are scheduled for pick up by a courier on July 1, 2026.

"Surveys were performed of the generators and storage unit with no readings noted as exceeding background.

"Inspectors have been in contact with the radiopharmacy where the generators originated and the courier company and will share information regarding this event with NRC Region 3 and the states of Indiana and Florida.

"This report will be updated following the July 1, 2026, pickup."

Illinois Item Number: IL260020


Non-Agreement State
Event Number: 58340
Rep Org: Curium
Licensee: Curium
Region: 3
City: Noblesville   State: IN
County:
License #: 13-35179-02
Agreement: N
Docket:
NRC Notified By: Cassandra Redmond
HQ OPS Officer: Adam Koziol
Notification Date: 06/30/2026
Notification Time: 16:55 [ET]
Event Date: 06/29/2026
Event Time: 13:00 [EDT]
Last Update Date: 06/30/2026
Emergency Class: Non Emergency
10 CFR Section:
30.50(b)(1) - Unplanned Contamination
Person (Organization):
Betancourt-Roldan, Diana (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
UNPLANNED CONTAMINATION

The following information was provided by the licensee via phone and email:

"On June 29, 2026, at approximately 1300 EDT, a quality assurance (QA) technician was conditionally releasing two batches of lutetium chloride in two separate safes/pigs when one of the safes slipped from their hand during transport and fell to the ground. The 6.53 Ci glass vial shattered on the laboratory floor, spilling the contents onto the floor and the pants/shoes/socks of the QA technician. The technician notified the nearest person in the lab of the spill and together they ensured the lab was evacuated, with the QA technician remaining at the lab entrance for assistance from health physics. The other individuals exited the laboratory and performed a whole-body survey using a portal monitor. The health physics manager/radiation safety officer (RSO) was notified of the personnel and area contamination and responded to the event.

"Health physics personnel found contamination on the pants, socks, and shoes of the QA technician. The contamination levels exceeded the count rate instrument scale. Health physics did not identify contamination on the skin of the individual.

"Health physics temporarily secured the affected laboratory to prevent the spread of contamination. Health physics assessed the spill from personnel statement of events and initiated the decontamination process. As a precaution, the health physics manager/RSO designated the laboratory area as double shoe covers required. Health physics initiated decontamination efforts and were able to reduce the contamination to approximately 100 mR/hr on contact in the spill area. Health physics collected air samples of the immediate area of the spill and analyzed the filter via gamma spectroscopy to identify the nuclides. The results indicated no presence of airborne contamination.

"The director of the radiation safety office and the health physics manager communicated the incident to the NRC Region III Inspector on Monday, June 29. Curium discussed the incident and data with the Region III Inspector, and agreed to reconnect on Tuesday, June 30. On Tuesday, June 30, Curium discussed with the NRC Region III Inspector an update of the contamination and dose levels as well as further actions to remediate. Curium and the NRC agreed that the incident met the intent of the notification criteria under 10 CFR 30.50(b)(1).

"Health physics discontinued the decontamination efforts on June 30 when the dose rates and contamination levels did not decrease, indicating that the residual contamination was now fixed to the floor. Health physics measured general area exposure rates to be 4-6 mR/hr, on contact with the affected floor to be approximately 90 mR/hr, and approximately 100,000 cpm of removable contamination."