Event Notification Report for June 25, 2026
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
06/24/2026 - 06/25/2026
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Agreement State
Event Number: 58316
Rep Org: Utah Division of Radiation Control
Licensee: HF Sinclair Woods Cross Refn, LLC
Region: 4
City: West Bountiful State: UT
County:
License #: UT 0600109
Agreement: Y
Docket:
NRC Notified By: Heather Mickelson
HQ OPS Officer: Karen Cotton
Licensee: HF Sinclair Woods Cross Refn, LLC
Region: 4
City: West Bountiful State: UT
County:
License #: UT 0600109
Agreement: Y
Docket:
NRC Notified By: Heather Mickelson
HQ OPS Officer: Karen Cotton
Notification Date: 06/11/2026
Notification Time: 19:08 [ET]
Event Date: 05/29/2026
Event Time: 01:30 [MDT]
Last Update Date: 06/24/2026
Notification Time: 19:08 [ET]
Event Date: 05/29/2026
Event Time: 01:30 [MDT]
Last Update Date: 06/24/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Dodson, Doug (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Dodson, Doug (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
EN Revision Imported Date: 6/25/2026
EN Revision Text: AGREEMENT STATE REPORT - STUCK OPEN GAUGE
The following information was provided by the Utah Division of Radiation Control via email:
"The Division of Waste Management and Radiation Control (DWMRC) was initially notified of a potential incident on June 11, 2026, at approximately 1530 MDT.
"On May 29, 2026, at approximately 1330 MDT, the licensee was verbally informed by a third-party service technician that two of their fixed gauges were stuck open.
"The licensee received the written report from a third-party service provider on June 11, 2026, at 1512 MDT. These gauges were in an HF [hydrofluoric] acid area.
"The gauges are an Ohmart SH-F1 Acid settler Interface 7LT502A and an Ohmart SHRM-P-84 containing 5 sources totaling 175 mCi.
"The licensee contacted the gauge manufacturer. The affected devices are scheduled to be replaced."
Utah Event Report ID No.: UT260005
* * * RETRACTION ON 06/24/2026 AT 1616 EDT FROM HEATHER MICKELSON TO ERNEST WEST * * *
The following information was provided by the Utah Division of Radiation Control via email:
This event is being retracted due to the gauges involved being the same gauges that were reported as having stuck open shutters in event notification number 58174.
Notified R4DO (Young) and NMSS Event Notifications (email)
EN Revision Text: AGREEMENT STATE REPORT - STUCK OPEN GAUGE
The following information was provided by the Utah Division of Radiation Control via email:
"The Division of Waste Management and Radiation Control (DWMRC) was initially notified of a potential incident on June 11, 2026, at approximately 1530 MDT.
"On May 29, 2026, at approximately 1330 MDT, the licensee was verbally informed by a third-party service technician that two of their fixed gauges were stuck open.
"The licensee received the written report from a third-party service provider on June 11, 2026, at 1512 MDT. These gauges were in an HF [hydrofluoric] acid area.
"The gauges are an Ohmart SH-F1 Acid settler Interface 7LT502A and an Ohmart SHRM-P-84 containing 5 sources totaling 175 mCi.
"The licensee contacted the gauge manufacturer. The affected devices are scheduled to be replaced."
Utah Event Report ID No.: UT260005
* * * RETRACTION ON 06/24/2026 AT 1616 EDT FROM HEATHER MICKELSON TO ERNEST WEST * * *
The following information was provided by the Utah Division of Radiation Control via email:
This event is being retracted due to the gauges involved being the same gauges that were reported as having stuck open shutters in event notification number 58174.
Notified R4DO (Young) and NMSS Event Notifications (email)
Agreement State
Event Number: 58323
Rep Org: Alabama Radiation Control
Licensee: Nucor Steel Tuscaloosa
Region: 1
City: Tuscaloosa State: AL
County:
License #: 1426
Agreement: Y
Docket:
NRC Notified By: Sean Williams
HQ OPS Officer: Christopher Prescott
Licensee: Nucor Steel Tuscaloosa
Region: 1
City: Tuscaloosa State: AL
County:
License #: 1426
Agreement: Y
Docket:
NRC Notified By: Sean Williams
HQ OPS Officer: Christopher Prescott
Notification Date: 06/18/2026
Notification Time: 08:45 [ET]
Event Date: 06/13/2026
Event Time: 08:30 [CDT]
Last Update Date: 06/18/2026
Notification Time: 08:45 [ET]
Event Date: 06/13/2026
Event Time: 08:30 [CDT]
Last Update Date: 06/18/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Schussler, Jason (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Schussler, Jason (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - DAMAGED GAUGE
The following information was provided by Alabama Office of Radiation Control via email:
"On June 13, 2026, at approximately 2030 CDT, the licensee's knife gate on the tundish latch of the mold failed, allowing the mold to overflow and damaging the locking pin of a GS300 Cs-137 gauge. The gauge shutter was closed, the gauge was surveyed, and no abnormal readings were observed. The gauge was placed into storage. The Ronan service representatives arrived on June 18, 2026, to package the gauge for shipment back to Ronan for either repair or replacement."
Gauge information:
Model: Ronan GS300
Source: 70 mCi Cs-137
Serial number: To be determined
The following information was provided by Alabama Office of Radiation Control via email:
"On June 13, 2026, at approximately 2030 CDT, the licensee's knife gate on the tundish latch of the mold failed, allowing the mold to overflow and damaging the locking pin of a GS300 Cs-137 gauge. The gauge shutter was closed, the gauge was surveyed, and no abnormal readings were observed. The gauge was placed into storage. The Ronan service representatives arrived on June 18, 2026, to package the gauge for shipment back to Ronan for either repair or replacement."
Gauge information:
Model: Ronan GS300
Source: 70 mCi Cs-137
Serial number: To be determined
Agreement State
Event Number: 58324
Rep Org: Illinois Emergency Mgmt. Agency
Licensee: Apave America, Inc
Region: 3
City: Robinson State: IL
County:
License #: IL-02481-01
Agreement: Y
Docket:
NRC Notified By: Robin G. Muzzalupo
HQ OPS Officer: Christopher Prescott
Licensee: Apave America, Inc
Region: 3
City: Robinson State: IL
County:
License #: IL-02481-01
Agreement: Y
Docket:
NRC Notified By: Robin G. Muzzalupo
HQ OPS Officer: Christopher Prescott
Notification Date: 06/18/2026
Notification Time: 10:27 [ET]
Event Date: 06/15/2026
Event Time: 14:00 [CDT]
Last Update Date: 06/18/2026
Notification Time: 10:27 [ET]
Event Date: 06/15/2026
Event Time: 14:00 [CDT]
Last Update Date: 06/18/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Nguyen, April (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Nguyen, April (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - STUCK RADIOGRAPHY SOURCE
The following information was provided by the Illinois Emergency Management Agency (the Agency) via phone and email:
"The Agency was contacted by the licensee on June 15, 2026, to advise on the recovery of a stuck Ir-192 source at the Marathon Plant in Robinson, IL. No exposures exceeding regulatory limits were reported.
"At 1400 CDT on June 15, 2026, a crew was performing radiography with a QSA 880-series Delta camera at the Marathon Plant in Robinson, IL, when the Ir-192 source became stuck in an unshielded position within the guide tube. Radiographers immediately extended barriers and notified the radiation safety officer and Marathon Plant safety staff. An individual authorized by the license to perform source retrievals responded and was able to return the source to its shielded position within the camera. The licensee indicated the source was out and unshielded for approximately 20 to 30 minutes. The radiographer reported that the source collimator was attached to a pipe with a vice clamp which likely created a tight angle in the guide tube. Retrieval personnel used specialized equipment to release the vice clamp and straighten the guide tube, which allowed the source to be safely cranked back to its shielded position within the camera. No exposure to the public was reported. Maximum exposure reported for the individual performing the source retrieval was 17 mrem.
"Inspectors conducted a reactive inspection on June 18, 2026, to review the incident details and confirm that no exposures to radiography personnel or the public exceeded regulatory limits. The event was then reported to NRC as an equipment failure."
Device Name: QSA 880-series Delta camera
S/N: 27296P
Source: 37.9 Ci Ir-192
Illinois item number: IL260017
The following information was provided by the Illinois Emergency Management Agency (the Agency) via phone and email:
"The Agency was contacted by the licensee on June 15, 2026, to advise on the recovery of a stuck Ir-192 source at the Marathon Plant in Robinson, IL. No exposures exceeding regulatory limits were reported.
"At 1400 CDT on June 15, 2026, a crew was performing radiography with a QSA 880-series Delta camera at the Marathon Plant in Robinson, IL, when the Ir-192 source became stuck in an unshielded position within the guide tube. Radiographers immediately extended barriers and notified the radiation safety officer and Marathon Plant safety staff. An individual authorized by the license to perform source retrievals responded and was able to return the source to its shielded position within the camera. The licensee indicated the source was out and unshielded for approximately 20 to 30 minutes. The radiographer reported that the source collimator was attached to a pipe with a vice clamp which likely created a tight angle in the guide tube. Retrieval personnel used specialized equipment to release the vice clamp and straighten the guide tube, which allowed the source to be safely cranked back to its shielded position within the camera. No exposure to the public was reported. Maximum exposure reported for the individual performing the source retrieval was 17 mrem.
"Inspectors conducted a reactive inspection on June 18, 2026, to review the incident details and confirm that no exposures to radiography personnel or the public exceeded regulatory limits. The event was then reported to NRC as an equipment failure."
Device Name: QSA 880-series Delta camera
S/N: 27296P
Source: 37.9 Ci Ir-192
Illinois item number: IL260017