Event Notification Report for March 11, 2026
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
03/10/2026 - 03/11/2026
Agreement State
Event Number: 58183
Rep Org: LA Dept of Environmental Quality
Licensee: Acuren Inspection, Inc
Region: 4
City: Baton Rouge State: LA
County:
License #: LA-7072-L01
Agreement: Y
Docket:
NRC Notified By: Scott Blackwell
HQ OPS Officer: Robert A. Thompson
Licensee: Acuren Inspection, Inc
Region: 4
City: Baton Rouge State: LA
County:
License #: LA-7072-L01
Agreement: Y
Docket:
NRC Notified By: Scott Blackwell
HQ OPS Officer: Robert A. Thompson
Notification Date: 03/03/2026
Notification Time: 16:26 [ET]
Event Date: 03/03/2026
Event Time: 09:45 [CST]
Last Update Date: 03/03/2026
Notification Time: 16:26 [ET]
Event Date: 03/03/2026
Event Time: 09:45 [CST]
Last Update Date: 03/03/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Dixon, John (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Grant, Jeffery (IR)
Dixon, John (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Grant, Jeffery (IR)
AGREEMENT STATE REPORT - UNATTENDED RADIOGRAPHY CAMERA
The following information was provided by the Louisiana Department of Environmental Quality (LDEQ) via email:
"On March 3, 2026, the site work coordinator at the ExxonMobil refinery in Baton Rouge reported that a radiography camera had been found unattended. The camera was discovered by an employee of IRIS Inspection Company.
"The licensee crew consisted of two state-carded radiographers and one instructor radiographer. The crew entered the unit, set up the barricade, and completed one exposure. After completing the exposure, they took down the barricade but inadvertently left the camera behind in the unit.
"The camera remained unattended for approximately one hour and was returned to Acuren at approximately 0945 CST."
Camera: QSA Delta 880, S/N D3706
Source: 27.6 curie Ir-192, S/N 24192P
LA Event Report ID: LA 20260005
THIS MATERIAL EVENT CONTAINS A 'Category 2' LEVEL OF RADIOACTIVE MATERIAL
Category 2 sources, if not safely managed or securely protected, could cause permanent injury to a person who handled them, or were otherwise in contact with them, for a short time (minutes to hours). It could possibly be fatal to be close to this amount of unshielded radioactive material for a period of hours to days. These sources are typically used in practices such as industrial gamma radiography, high dose rate brachytherapy and medium dose rate brachytherapy. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following information was provided by the Louisiana Department of Environmental Quality (LDEQ) via email:
"On March 3, 2026, the site work coordinator at the ExxonMobil refinery in Baton Rouge reported that a radiography camera had been found unattended. The camera was discovered by an employee of IRIS Inspection Company.
"The licensee crew consisted of two state-carded radiographers and one instructor radiographer. The crew entered the unit, set up the barricade, and completed one exposure. After completing the exposure, they took down the barricade but inadvertently left the camera behind in the unit.
"The camera remained unattended for approximately one hour and was returned to Acuren at approximately 0945 CST."
Camera: QSA Delta 880, S/N D3706
Source: 27.6 curie Ir-192, S/N 24192P
LA Event Report ID: LA 20260005
THIS MATERIAL EVENT CONTAINS A 'Category 2' LEVEL OF RADIOACTIVE MATERIAL
Category 2 sources, if not safely managed or securely protected, could cause permanent injury to a person who handled them, or were otherwise in contact with them, for a short time (minutes to hours). It could possibly be fatal to be close to this amount of unshielded radioactive material for a period of hours to days. These sources are typically used in practices such as industrial gamma radiography, high dose rate brachytherapy and medium dose rate brachytherapy. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Power Reactor
Event Number: 58186
Facility: Byron
Region: 3 State: IL
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: Jacob Benner
HQ OPS Officer: Brian P. Smith
Region: 3 State: IL
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: Jacob Benner
HQ OPS Officer: Brian P. Smith
Notification Date: 03/09/2026
Notification Time: 01:15 [ET]
Event Date: 03/08/2026
Event Time: 17:17 [CDT]
Last Update Date: 03/09/2026
Notification Time: 01:15 [ET]
Event Date: 03/08/2026
Event Time: 17:17 [CDT]
Last Update Date: 03/09/2026
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(ii)(A) - Degraded Condition
10 CFR Section:
50.72(b)(3)(ii)(A) - Degraded Condition
Person (Organization):
Edwards, Rhex (R3DO)
Edwards, Rhex (R3DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | N | 0 | Refueling | 0 | Refueling |
DEGRADED REACTOR VESSEL CLOSURE HEAD PENETRATION
The following information was provided by the licensee via phone and email:
"At 1717 CDT on March 8, 2026, during the Byron Unit 1 refueling outage, it was determined that the control rod drive mechanism (CRDM) penetration 31 was degraded because liquid penetrant testing performed on the embedded flaw repair weld identified an unacceptable rounded indication, in accordance with American Society of Mechanical Engineers (ASME) Section III acceptance standards and an NRC-approved licensee relief request for a previously performed embedded flaw repair. Required repairs will be completed in accordance with the ASME code of record prior to returning the vessel head to service. Therefore, this event is being reported as an eight-hour, non-emergency notification per 10 CFR 50.72(b)(3)(ii)(A).
"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."
The following information was provided by the licensee via phone and email:
"At 1717 CDT on March 8, 2026, during the Byron Unit 1 refueling outage, it was determined that the control rod drive mechanism (CRDM) penetration 31 was degraded because liquid penetrant testing performed on the embedded flaw repair weld identified an unacceptable rounded indication, in accordance with American Society of Mechanical Engineers (ASME) Section III acceptance standards and an NRC-approved licensee relief request for a previously performed embedded flaw repair. Required repairs will be completed in accordance with the ASME code of record prior to returning the vessel head to service. Therefore, this event is being reported as an eight-hour, non-emergency notification per 10 CFR 50.72(b)(3)(ii)(A).
"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."
Power Reactor
Event Number: 58187
Facility: Clinton
Region: 3 State: IL
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: Roger Ingalsbe
HQ OPS Officer: Rodney Clagg
Region: 3 State: IL
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: Roger Ingalsbe
HQ OPS Officer: Rodney Clagg
Notification Date: 03/09/2026
Notification Time: 17:07 [ET]
Event Date: 03/09/2026
Event Time: 08:33 [CDT]
Last Update Date: 03/09/2026
Notification Time: 17:07 [ET]
Event Date: 03/09/2026
Event Time: 08:33 [CDT]
Last Update Date: 03/09/2026
Emergency Class: Non Emergency
10 CFR Section:
26.719 - Fitness For Duty
10 CFR Section:
26.719 - Fitness For Duty
Person (Organization):
Edwards, Rhex (R3DO)
FFD Group, (EMAIL)
Edwards, Rhex (R3DO)
FFD Group, (EMAIL)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
FITNESS FOR DUTY
The following information was provided by the licensee via phone and email:
"At 0833 CDT on 03/09/2026, it was determined that a licensed operator tested positive in accordance with the FFD testing program. The individual's authorization for site access has been terminated.
"The NRC Resident Inspector has been notified."
The following information was provided by the licensee via phone and email:
"At 0833 CDT on 03/09/2026, it was determined that a licensed operator tested positive in accordance with the FFD testing program. The individual's authorization for site access has been terminated.
"The NRC Resident Inspector has been notified."
Hospital
Event Number: 58184
Rep Org: Georgetown Univ Hospital
Licensee: Georgetown Univ Hospital
Region: 1
City: Washingon State: DC
County:
License #: 08-30577-01
Agreement: N
Docket:
NRC Notified By: Auroba Latief Al-Samaraee
HQ OPS Officer: Robert A. Thompson
Licensee: Georgetown Univ Hospital
Region: 1
City: Washingon State: DC
County:
License #: 08-30577-01
Agreement: N
Docket:
NRC Notified By: Auroba Latief Al-Samaraee
HQ OPS Officer: Robert A. Thompson
Notification Date: 03/04/2026
Notification Time: 11:56 [ET]
Event Date: 03/03/2026
Event Time: 10:38 [EST]
Last Update Date: 03/04/2026
Notification Time: 11:56 [ET]
Event Date: 03/03/2026
Event Time: 10:38 [EST]
Last Update Date: 03/04/2026
Emergency Class: Non Emergency
10 CFR Section:
35.3045(a)(1)(i) - Dose <> Prescribed Dosage
10 CFR Section:
35.3045(a)(1)(i) - Dose <> Prescribed Dosage
Person (Organization):
Eve, Elise (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Eve, Elise (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
MEDICAL EVENT
The following information was provided by the licensee via phone:
On March 3, 2026, at 1038 EST, a 200 mCi Lu-177 Lutathera treatment for a metastatic neuroendocrine tumor had commenced when the patient informed the treatment team that he had received an injection that morning. It was determined that the patient had been administered an octreotide injection. The physician ordered an immediate stop to the Lutathera infusion as the octreotide would prevent take-up of the Lu-177. Only 19 mCi of the planned 200 mCi dose was administered.
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
The following information was provided by the licensee via phone:
On March 3, 2026, at 1038 EST, a 200 mCi Lu-177 Lutathera treatment for a metastatic neuroendocrine tumor had commenced when the patient informed the treatment team that he had received an injection that morning. It was determined that the patient had been administered an octreotide injection. The physician ordered an immediate stop to the Lutathera infusion as the octreotide would prevent take-up of the Lu-177. Only 19 mCi of the planned 200 mCi dose was administered.
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
Power Reactor
Event Number: 58190
Facility: Palo Verde
Region: 4 State: AZ
Unit: [1] [2] [3]
RX Type: [1] CE,[2] CE,[3] CE
NRC Notified By: Jeremia Mueller
HQ OPS Officer: Karen Cotton
Region: 4 State: AZ
Unit: [1] [2] [3]
RX Type: [1] CE,[2] CE,[3] CE
NRC Notified By: Jeremia Mueller
HQ OPS Officer: Karen Cotton
Notification Date: 03/10/2026
Notification Time: 18:33 [ET]
Event Date: 03/10/2026
Event Time: 11:34 [MST]
Last Update Date: 03/10/2026
Notification Time: 18:33 [ET]
Event Date: 03/10/2026
Event Time: 11:34 [MST]
Last Update Date: 03/10/2026
Emergency Class: Non Emergency
10 CFR Section:
26.719 - Fitness For Duty
10 CFR Section:
26.719 - Fitness For Duty
Person (Organization):
Dixon, John (R4DO)
FFD Group, (EMAIL)
Dixon, John (R4DO)
FFD Group, (EMAIL)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 3 | N | Y | 100 | Power Operation | 100 | Power Operation |
FITNESS FOR DUTY
The following information was provided by the licensee via phone and email:
"On March 10, 2026, at 1134 MST, a reactor operator's test results were confirmed positive for alcohol following a for-cause, fitness for duty screening test. The individual's unescorted access has been immediately placed on administrative hold until the denial process has been completed per station procedures.
"The NRC Resident Inspector has been notified."
The following information was provided by the licensee via phone and email:
"On March 10, 2026, at 1134 MST, a reactor operator's test results were confirmed positive for alcohol following a for-cause, fitness for duty screening test. The individual's unescorted access has been immediately placed on administrative hold until the denial process has been completed per station procedures.
"The NRC Resident Inspector has been notified."