Event Notification Report for February 05, 2026

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
02/04/2026 - 02/05/2026

Non-Agreement State
Event Number: 58132
Rep Org: AMC Theater Ward Parkway 14
Licensee: AMC Theater Ward Parkway 14
Region: 3
City: Kansas City   State: MO
County:
License #: General
Agreement: N
Docket:
NRC Notified By: Monica Diaz
HQ OPS Officer: Ernest West
Notification Date: 01/28/2026
Notification Time: 10:15 [ET]
Event Date: 11/05/2025
Event Time: 00:00 [CST]
Last Update Date: 01/28/2026
Emergency Class: Non Emergency
10 CFR Section:
20.2201(a)(1)(i) - Lost/Stolen LNM>1000x
Person (Organization):
Orlikowski, Robert (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
Event Text
LOST EXIT SIGN

The following is a summary of information that was provided by a Wiedenbach Brown representative via phone:

Wiedenbach Brown coordinated disposal of an expired tritium exit sign on behalf of the licensee, AMC Theater Ward Parkway 14. On 11/5/2025, a third party was hired to retrieve the exit sign and send it to the manufacturer for disposal. When the paperwork to ship out the exit sign was received, the technician for the third-party company couldn't locate the expired exit sign.

Manufacturer: Isolite
Model number: 880-12-6
Serial number: H227725
Activity: 12.16 Ci



THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Agreement State
Event Number: 58133
Rep Org: CT Dept of Environmental Protection
Licensee: SCAPA Tapes
Region: 1
City: Windsor   State: CT
County:
License #: General License
Agreement: Y
Docket:
NRC Notified By: Kristina Verderame
HQ OPS Officer: Josue Ramirez
Notification Date: 01/28/2026
Notification Time: 15:35 [ET]
Event Date: 01/28/2026
Event Time: 15:25 [EST]
Last Update Date: 01/28/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Bickett, Carey (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
Event Text
AGREEMENT STATE REPORT - LOST GAUGE

The following information was provided by the Connecticut Department of Energy and Environmental Protection, Radiation Division, (DEEP) via phone and email:

"On January 28, 2026, at 1525 EST, DEEP, received notification that the general licensee, SCAPA Tapes was unable to locate a general licensed (GL) device, NDC Infrared Engineering, Inc. Model 103, Serial no. 3684 containing 150 millicuries of Americium-241. The GL device had been removed from service in 2025 and was placed in storage to be used as a spare device. After an extensive search, the GL device has not been located and is being reported per 10 CFR 20.2201(a)(1)(i). The licensee will submit a 30-day report."

CT event number: CT-26-0002


THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Agreement State
Event Number: 58134
Rep Org: Florida Bureau of Radiation Control
Licensee: Federal Engineering and Testing
Region: 1
City: Belle Glade   State: FL
County:
License #: 4414-1
Agreement: Y
Docket:
NRC Notified By: Ashley Pierre-Saint
HQ OPS Officer: Brian P. Smith
Notification Date: 01/28/2026
Notification Time: 16:22 [ET]
Event Date: 01/28/2026
Event Time: 14:45 [EST]
Last Update Date: 01/28/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Bickett, Carey (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - DAMAGED TROXLER GAUGE

The following information was provided by the Florida Bureau of Radiation Protection via email:

"At approximately 1445 [EST], Federal Engineering & Testing's radiation safety officer (RSO) was notified by an on-site technician of an incident involving a Troxler soil moisture density gauge. The gauge was struck by a dump truck while in use during a soil survey in the Everglades near the Belle Glade area. The technician reports that the source rod remains intact; however, the plastic casing of the gauge is crushed. The RSO is responding to the site to verify the condition of the source using a survey meter."

Florida event number: FL26-006


Agreement State
Event Number: 58136
Rep Org: California Radiation Control Prgm
Licensee: Loma Linda University
Region: 4
City: Loma Linda   State: CA
County:
License #: 0060-36
Agreement: Y
Docket:
NRC Notified By: Donald Oesterle
HQ OPS Officer: Josue Ramirez
Notification Date: 01/29/2026
Notification Time: 14:19 [ET]
Event Date: 01/27/2026
Event Time: 00:00 [PST]
Last Update Date: 01/29/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Dixon, John (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - MEDICAL EVENT

The following information was provided by California Department of Public Health, Radiologic Health Branch via email:

"On January 27, 2026, a patient treatment with Y-90 Theraspheres was conducted at the Loma Linda University Medical Center in which a therapeautic dose of 5.4 GBq (146 mCi) was prepared for administration to an individual. During the procedure, administration problems occurred and the dose to be administered was measured to be 25 percent of the prescribed measurement which had been determined.

"The remaining dosage and delivery system have been isolated in order to decay to the point where it can be sent back to the supplying vendor for investigation and assessment of reasons for the equipment failure. This is being reported to the NRC as a 10 CFR 35.3045 A, B, and C medical event due to the administered dose being less than 20 percent and less than 50 percent of the prescribed dosage."


California event number: 012826

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.


Power Reactor
Event Number: 58148
Facility: River Bend
Region: 4     State: LA
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: Terry Blanchard
HQ OPS Officer: Josue Ramirez
Notification Date: 02/04/2026
Notification Time: 07:09 [ET]
Event Date: 02/03/2026
Event Time: 23:38 [CST]
Last Update Date: 02/04/2026
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation 50.72(b)(3)(v)(D) - Accident Mitigation
Person (Organization):
O'Keefe, Neil (R4DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
EN Revision Imported Date: 2/5/2026

EN Revision Text: EDG ACTUATION AND HPCS SYSTEM INOPERABLE

The following information was provided by the licensee via phone and email:

"On February 3, 2026, at 2338 CST, River Bend Station (RBS) was operating at 100 percent reactor power when the standby service water pump `C' (SWP-P2C) faulted, tripped, and locked out during the performance of a routine surveillance. The pump fault caused E22-ACB04, the normal division III 4.16 KV bus supply breaker, to trip and lock out. The division Ill emergency diesel generator (EDG) started as designed and powered the division III 4.16 KV bus. There are no signs of fire. The cause of the SWP-P2C fault is still under investigation.
"The trip of E22-ACB04 resulted in the inability to meet [surveillance requirement] SR 3.8.9.1 forcing entry into [limiting condition for operation] LCO 3.8.9 required action 'E.1' and declaring the [high-pressure core spray] HPCS system inoperable.
"This event is being reported under 10 CFR 50.72(b)(3)(iv)(A) as an event or condition that results in valid actuation of emergency AC electrical power systems and 10 CFR 50.72(b)(3)(v)(D) as an event or condition that at the time of discovery could have prevented the fulfillment of a safety function.

"The NRC Resident has been notified."


Power Reactor
Event Number: 58150
Facility: Cook
Region: 3     State: MI
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: Amanda Schnipke
HQ OPS Officer: Eric Simpson
Notification Date: 02/04/2026
Notification Time: 14:10 [ET]
Event Date: 01/26/2026
Event Time: 10:58 [EST]
Last Update Date: 02/04/2026
Emergency Class: Non Emergency
10 CFR Section:
21.21(d)(3)(i) - Defects And Noncompliance
Person (Organization):
Nguyen, April (R3DO)
Part 21/50.55 Reactors, - (EMAIL)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
PART 21 - INCORRECT TENSION SPRING USED FOR 600V BREAKERS

The following information was provided by the licensee via phone and email:

"This is an initial report notification pursuant to 10 CFR Part 21.21.

"On January 1, 2026, Cook Nuclear Plant completed a Part 21 evaluation concerning an issue with the refurbishment kit used for K-Line series 600V Breakers supplied by ABB, Inc. An incorrect tension spring was supplied in one of the refurbishment kits. The refurbishment kits should be supplied with two tension springs: P/N 650216A00 and P/N 650216E00. The kit received was missing P/N 650216A00 and had two of P/N 650216E00. The incorrect 650216E00 spring could have been installed into a K-Line series 600V breaker in the location intended to accept the 650216A00 spring. The 650216E00 is a lighter spring and may not be capable of providing the tensioning force required to prevent an aged breaker from slow closing. A breaker's failure to charge and close properly could result in an arc fault condition. The breakers were inspected for the correct spring, which is visible from the front of the breaker between a gap in the mechanism cover and the charging handle. All breakers installed appear to have the correct springs installed.

"One spare breaker, not installed in the plant, appears to have had the incorrect spring installed. A written notification will be provided within 30 days."

Affected Plants: Cook Nuclear Power Plant.

The NRC Resident has been notified.

The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:

The wrong part numbers were identified in the refurbishment kits on December 1, 2025. A site engineer noted the wrong spring installed in a spare breaker as part of the Part 21 evaluation. Corrective actions included notifying the vendor and returning the unused refurbishment kits.


Power Reactor
Event Number: 58152
Facility: Harris
Region: 2     State: NC
Unit: [1] [] []
RX Type: [1] W-3-LP
NRC Notified By: Scott Faulkner
HQ OPS Officer: Ernest West
Notification Date: 02/04/2026
Notification Time: 21:00 [ET]
Event Date: 02/04/2026
Event Time: 18:52 [EST]
Last Update Date: 02/04/2026
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(xi) - Offsite Notification
Person (Organization):
Michel, Eric (R2DO)
Mckenna, Phillip (NRR EO)
Grant, Jeffery (IR)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
OFFSITE NOTIFICATION FOR ONSITE FATALITY

The following information was provided by the licensee via phone and email:

"At 1659 EST, offsite medical personnel [arrived on site and] declared a site employee deceased due to a non-work-related medical event inside the radiation control area. The individual was not contaminated. A notification to the Occupational Health and Safety Administration was made in accordance with regulatory requirements at 1852 EST. This is a four-hour non-emergency notification for notification of another government agency. This event is reportable in accordance with 10 CFR 50.72(b)(2)(xi).

"The NRC Resident Inspector has been notified."