Event Notification Report for January 30, 2026
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
01/29/2026 - 01/30/2026
Part 21
Event Number: 58135
Rep Org: Paragon Energy Solutions
Licensee:
Region: 2
City: Spring City State: TN
County:
License #:
Agreement: Y
Docket:
NRC Notified By: Richard Knott
HQ OPS Officer: Josue Ramirez
Licensee:
Region: 2
City: Spring City State: TN
County:
License #:
Agreement: Y
Docket:
NRC Notified By: Richard Knott
HQ OPS Officer: Josue Ramirez
Notification Date: 01/28/2026
Notification Time: 17:01 [ET]
Event Date: 01/26/2026
Event Time: 00:00 [EST]
Last Update Date: 01/28/2026
Notification Time: 17:01 [ET]
Event Date: 01/26/2026
Event Time: 00:00 [EST]
Last Update Date: 01/28/2026
Emergency Class: Non Emergency
10 CFR Section:
21.21(d)(3)(i) - Defects And Noncompliance
10 CFR Section:
21.21(d)(3)(i) - Defects And Noncompliance
Person (Organization):
Michel, Eric (R2DO)
Part 21/50.55 Reactors, - (EMAIL)
Michel, Eric (R2DO)
Part 21/50.55 Reactors, - (EMAIL)
PART 21 - DEFECT WITH ELECTRIC ACTUATORS
The following is a summary of information provided by Paragon Energy Solutions, LLC via email:
Tennessee Valley Authority (TVA) experienced binding in several actuators (Schneider Electric part number MA-418-0-0-4) used to operate dampers associated with emergency diesel generator room ventilation. Paragon identified that precipitate particles from the lubricating oil can collect in the space between the small motor rotor and the stator thus preventing rotation of the shaft connected to the damper actuating linkage. This condition, if left uncorrected, could contribute to a safety hazard.
Paragon is working with TVA to define the extent of the condition and recommends Watts Bar segregate any spare actuators from the lots and monitor in service MA-418 actuator motors from different lots supplied for similar issues.
Paragon contact: Richard Knott, Vice President Quality Assurance, Paragon Energy Solutions, LLC, 7410 Pebble Drive, Fort Worth, TX 76118, 817-284-0077, rknott@paragones.com.
Affected plant: Watts Bar
The following is a summary of information provided by Paragon Energy Solutions, LLC via email:
Tennessee Valley Authority (TVA) experienced binding in several actuators (Schneider Electric part number MA-418-0-0-4) used to operate dampers associated with emergency diesel generator room ventilation. Paragon identified that precipitate particles from the lubricating oil can collect in the space between the small motor rotor and the stator thus preventing rotation of the shaft connected to the damper actuating linkage. This condition, if left uncorrected, could contribute to a safety hazard.
Paragon is working with TVA to define the extent of the condition and recommends Watts Bar segregate any spare actuators from the lots and monitor in service MA-418 actuator motors from different lots supplied for similar issues.
Paragon contact: Richard Knott, Vice President Quality Assurance, Paragon Energy Solutions, LLC, 7410 Pebble Drive, Fort Worth, TX 76118, 817-284-0077, rknott@paragones.com.
Affected plant: Watts Bar
Agreement State
Event Number: 58126
Rep Org: SC Dept of Health & Env Control
Licensee: NAN YA Plastics Corp.
Region: 1
City: Lake City State: SC
County:
License #: 471
Agreement: Y
Docket:
NRC Notified By: Jacob Price
HQ OPS Officer: Kerby Scales
Licensee: NAN YA Plastics Corp.
Region: 1
City: Lake City State: SC
County:
License #: 471
Agreement: Y
Docket:
NRC Notified By: Jacob Price
HQ OPS Officer: Kerby Scales
Notification Date: 01/23/2026
Notification Time: 17:43 [ET]
Event Date: 01/23/2026
Event Time: 00:00 [EST]
Last Update Date: 01/23/2026
Notification Time: 17:43 [ET]
Event Date: 01/23/2026
Event Time: 00:00 [EST]
Last Update Date: 01/23/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Bickett, Carey (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Bickett, Carey (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - STUCK SOURCE
The following information was provided by the South Carolina Department of Environmental Services (the Department) via phone and email:
"The licensee informed the Department via telephone on January 23, 2026, that a fixed gauging device was disabled or failed to function as designed. The licensee reported that a sealed source was stuck (exposed) in a dip tube assembly that was attached to a process vessel. The licensee reported that a representative from a licensed service provider was on-site and was able to remove the sealed source from the dip tube assembly, and placed the sealed source into a transport shield. The sealed source is a 9 millicurie cobalt-60 Berthold model P2608-100 sealed source. The licensee did not report any overexposures or ongoing health/safety concerns. This event is still under investigation by the Department."
The following information was provided by the South Carolina Department of Environmental Services (the Department) via phone and email:
"The licensee informed the Department via telephone on January 23, 2026, that a fixed gauging device was disabled or failed to function as designed. The licensee reported that a sealed source was stuck (exposed) in a dip tube assembly that was attached to a process vessel. The licensee reported that a representative from a licensed service provider was on-site and was able to remove the sealed source from the dip tube assembly, and placed the sealed source into a transport shield. The sealed source is a 9 millicurie cobalt-60 Berthold model P2608-100 sealed source. The licensee did not report any overexposures or ongoing health/safety concerns. This event is still under investigation by the Department."