Skip to main content

Event Notification Report for January 15, 2026

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
01/14/2026 - 01/15/2026

EVENT NUMBERS
581105811158115
Agreement State
Event Number: 58110
Rep Org: New York City Dept of Health
Licensee: Memorial Sloan-Kettering
Region: 1
City: New York   State: NY
County:
License #: 75-2968-01
Agreement: Y
Docket:
NRC Notified By: Erik Finkelstein
HQ OPS Officer: Troy Johnson
Notification Date: 01/07/2026
Notification Time: 10:07 [ET]
Event Date: 11/26/2025
Event Time: 00:00 [EST]
Last Update Date: 01/07/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Seeley, Shawn (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - MEDICAL EVENT

The following is a summary of information provided by the New York City Department of Health (NYC DOH) via email:

Only 63 Gy of a planned 151 Gy treatment of Y-90 microspheres to the liver was delivered, or 42 percent of the intended dose. The licensee identified the likely cause as a faulty connection between the tubing in the administration kit and the catheter.

The treatment occurred on November 26, 2025, and was reported to NYC DOH on December 1, 2025.

NYC item number: NY260001

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.


Agreement State
Event Number: 58111
Rep Org: Louisiana Department of Environmental Quality
Licensee: Chalmette Refining, LLC
Region: 4
City: Chalmette   State: LA
County:
License #: LA-2247-L01
Agreement: Y
Docket:
NRC Notified By: James M. Pate III
HQ OPS Officer: Troy Johnson
Notification Date: 01/07/2026
Notification Time: 11:50 [ET]
Event Date: 01/06/2026
Event Time: 13:00 [CST]
Last Update Date: 01/07/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - STUCK SHUTTER

The following information was provided by the Louisiana Department of Environmental Quality (LDEQ) via email:

"On January 07, 2026, Chalmette Refining, LLC contacted LDEQ concerning a stuck shutter on a fixed gauge identified on January 6, 2026. The shutter is stuck in the open position. The fixed gauge is located on the acid evacuation drum. The licensee has determined that it will be replacing the fixed gauge housing and source with a new fixed gauge housing and source."

Gauge: Ohmart model SH-F2B, S/N 1135CM
Source: Cs-137, 0.8 Ci, model A-2102

LA event report ID number: LA20260001


Power Reactor
Event Number: 58115
Facility: Summer
Region: 2     State: SC
Unit: [1] [] []
RX Type: [1] W-3-LP,[2] W-AP1000,[3] W-AP1000
NRC Notified By: Jason Pawlack
HQ OPS Officer: Jon Lilliendahl
Notification Date: 01/14/2026
Notification Time: 17:26 [ET]
Event Date: 01/14/2026
Event Time: 07:44 [EST]
Last Update Date: 01/14/2026
Emergency Class: Non Emergency
10 CFR Section:
26.719 - Fitness For Duty
Person (Organization):
Michel, Eric (R2DO)
FFD Group, (EMAIL)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
FITNESS FOR DUTY EVENT

The following information was provided by the licensee via phone and email:

"At 0744 EST on January 14, 2026, it was determined that an individual in a non-licensed supervisory role failed a test specified by the FFD testing program. The individual's authorization for site access has been terminated.

"The NRC Resident Inspector has been notified."