Skip to main content

Event Notification Report for November 06, 2025

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
11/05/2025 - 11/06/2025

EVENT NUMBERS
5803058029
Agreement State
Event Number: 58030
Rep Org: Virginia Rad Materials Program
Licensee: ATCS, PLC
Region: 1
City: Wytheville   State: VA
County:
License #: 059-250-1
Agreement: Y
Docket:
NRC Notified By: Sheila Nelson
HQ OPS Officer: Karen Cotton
Notification Date: 11/07/2025
Notification Time: 11:22 [ET]
Event Date: 11/06/2025
Event Time: 11:20 [EST]
Last Update Date: 11/07/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Young, Matt (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - DAMAGED GAUGE

The following is a summary of information provided by the Virginia Radioactive Materials Program (VRMP) via email:

The VRMP was notified by phone of an incident at a soil compaction project site in Wytheville, VA. At approximately 1120 EST, on November 6, 2025, a Troxler 3440 portable nuclear gauge (S/N 71116, 8 mCi Cs-137 and 40 mCi Am-241) was struck by a motor grader while the rod was locked in the safe position within the gauge. The authorized user (AU) was approximately 100 yards from the unattended gauge when the incident occurred. The AU secured the area and contacted their radiation safety officer (RSO) to report the incident. The impact damaged the plastic housing, bent the source rod handle, and broke the depth rod off the device. The licensee and Virginia Department of Transportation (VDOT) RSOs verified the source rod was still locked within the gauge shielding and there was no apparent damage to either source capsules. Surveys indicated the radiation levels were within acceptable ranges. The licensee RSO reported that there were no exposures or injuries. Surveys of the surrounding area and grader tires showed only background radioactivity. The gauge was placed into its transport case and returned to the licensed storage location. A leak test will be performed, and the gauge will be transported to North East Technical Services, Inc., a licensed nuclear gauge service company in Maryland, for further evaluation. VRMP will investigate the licensee.

Virginia event report ID number: VA250005


Power Reactor
Event Number: 58029
Facility: Millstone
Region: 1     State: CT
Unit: [3] [] []
RX Type: [1] GE-3,[2] CE,[3] W-4-LP
NRC Notified By: Ted Di Angelo II
HQ OPS Officer: Ernest West
Notification Date: 11/06/2025
Notification Time: 16:30 [ET]
Event Date: 11/06/2025
Event Time: 10:14 [EST]
Last Update Date: 11/06/2025
Emergency Class: Non Emergency
10 CFR Section:
26.719 - Fitness For Duty
Person (Organization):
Young, Matt (R1DO)
FFD Group, (EMAIL)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 N Y 100 Power Operation 100 Power Operation
Event Text
FITNESS FOR DUTY EVENT

The following information was provided by the licensee via phone and email:

"On November 6, 2025, at 1014 [EST], it was determined that a licensed supervisory operator was in violation of the licensee's fitness for duty (FFD) policy. The test result was negative but determined to be reportable under 10 CFR 26.719(b)(2)(ii) due to violation of the licensee's FFD policy. The employee's unescorted access has been placed on hold in accordance with the licensee's FFD policy.

"The NRC Senior Resident Inspector has been notified."