Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for October 27, 2025

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
10/26/2025 - 10/27/2025

Power Reactor
Event Number: 57987
Facility: Summer
Region: 2     State: SC
Unit: [1] [] []
RX Type: [1] W-3-LP,[2] W-AP1000,[3] W-AP1000
NRC Notified By: Lauren Anderson
HQ OPS Officer: Brian P. Smith
Notification Date: 10/14/2025
Notification Time: 17:47 [ET]
Event Date: 10/14/2025
Event Time: 15:52 [EDT]
Last Update Date: 10/25/2025
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical 50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
Person (Organization):
Mckown, Louis J (R2DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 A/R Y 100 0
Event Text
EN Revision Imported Date: 10/27/2025

EN Revision Text: AUTOMATIC REACTOR TRIP

The following information was provided by the licensee via phone and email:

"At 1552 EDT on October 14, 2025, with Unit 1 in mode 1 at 100 percent power, the reactor automatically tripped due to a turbine trip. The trip was not complex with all systems responding normally post-trip.

"Operations responded and stabilized the plant. Decay heat is being removed by the emergency feedwater system.

"Due to the reactor protection system actuation while critical, this event is being reported as a 4-hour, non-emergency notification per 10 CFR 50.72(b)(2)(iv)(B) and an 8-hour, non-emergency notification per 10 CFR 50.72(b)(3)(iv)(A) for valid actuation of the reactor protection and emergency feedwater systems. There was no impact on the health and safety of the public or plant personnel. The NRC resident inspector has been notified."

The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:

A generator field breaker lockout occurred. In addition, a small fire was observed in the generator field breaker and extinguished in less than 15 minutes by the onsite fire brigade. The unit is stable in hot standby with emergency feedwater and main condenser steam dumps in-service.


Agreement State
Event Number: 57993
Rep Org: Florida Bureau of Radiation Control
Licensee: UF Health Jacksonville
Region: 1
City: Jacksonville   State: FL
County:
License #: 3157-1
Agreement: Y
Docket:
NRC Notified By: Monroe A. Cooper
HQ OPS Officer: Josue Ramirez
Notification Date: 10/20/2025
Notification Time: 13:54 [ET]
Event Date: 10/16/2025
Event Time: 00:00 [EDT]
Last Update Date: 10/28/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Young, Matt (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
EN Revision Imported Date: 10/28/2025

EN Revision Text: AGREEMENT STATE REPORT - MEDICAL EVENT

The following information was provided by the Florida Bureau of Radiation Control (BRC) via email:

"Florida BRC received notification of a medical event which occurred at UF Health Jacksonville. A patient received an I-125 seed for breast localization surgery. The seed was implanted on Wednesday October 15, 2025, and was intended to be removed on October 16, 2025.

"On October 16, 2025, the patient required an emergency surgery, which included receiving a stent, resulting in the patient's inability to receive additional surgeries for approximately 3 months. The patient and physician are aware of the situation, and the facility is working towards determining non-surgical options.

"The NRC has received notification due to the expectation that the received dose will be greater than 20 percent of the intended dose. The facility has been requested to provide the patient's expected dose and received dose. The incident, and the NRC, will be updated when this information is received."

Seed information:
Manufacturer: IsoAid
Model: IAI-125A
Isotope: I-125
Activity: 0.298 mCi

* * * UPDATE ON 10/27/2025 AT 0733 EDT FROM MONROE COOPER TO IAN HOWARD * * *

The following information was provided by the Florida Bureau of Radiation Control (BRC) via email:

"The intended maximum dose was 2792 cGy. The expected maximum dose is 156793 cGy."

Notified R1DO (Young), NMSS (Kock), NMSS Events Notifications (email).

Florida Incident Number: FL25-102

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.


Power Reactor
Event Number: 58006
Facility: Palisades
Region: 3     State: MI
Unit: [1] [] []
RX Type: [1] CE
NRC Notified By: Aaron McVay
HQ OPS Officer: Ian Howard
Notification Date: 10/26/2025
Notification Time: 08:14 [ET]
Event Date: 10/25/2025
Event Time: 12:30 [EDT]
Last Update Date: 10/26/2025
Emergency Class: Non Emergency
10 CFR Section:
26.719 - Fitness For Duty
Person (Organization):
Edwards, Rhex (R3DO)
FFD Group, (EMAIL)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 0
Event Text
FITNESS FOR DUTY (FFD) EVENT

The following information was provided by the licensee via phone and email:

"On 10/25/25, at approximately 1230 EDT, 3 empty alcohol bottles were found in the protected area by a contract employee. Site security was notified and took possession of the empty bottles which were removed from the protected area. The individual who accidentally brought in the empty alcohol bottles with other non-alcoholic empty bottles was tested for FFD and was negative. This event is reportable in accordance with 10 CFR 26.719(b).

"The NRC Resident Inspector has been notified."


Power Reactor
Event Number: 58007
Facility: Waterford
Region: 4     State: LA
Unit: [3] [] []
RX Type: [3] CE
NRC Notified By: Jean-Luc Guilbeaux
HQ OPS Officer: Ian Howard
Notification Date: 10/26/2025
Notification Time: 09:29 [ET]
Event Date: 10/26/2025
Event Time: 00:40 [CDT]
Last Update Date: 10/26/2025
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(v)(D) - Accident Mitigation
Person (Organization):
Vossmar, Patricia (R4DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 N Y 94 94
Event Text
CONTROL ROOM ENVELOPE INOPERABLE

The following information was provided by the licensee via phone and email:

"On October 26, 2025, at 0040 CDT, the Waterford 3 Steam Electric Unit 3 operating crew declared the control room envelope inoperable in accordance with technical specification (TS) 3.7.6.1 due to the discovery of a hairline crack in the station air supply header in the passageway outside the control room.

"Operations entered TS 3.7.6.1 action b. TS 3.7.6.1 action b was complied with by closing manual valves SA-502 and SA-514, thus isolating the section of piping that developed the crack. The station air leak was isolated at time 0120. There was no impact on the health and safety of the plant or plant personnel.

"This event is reportable pursuant to 10 CFR 50.72(b)(3)(v)(D), event or condition that could have prevented fulfillment of a safety function of structures or systems that are needed to `(D) mitigate the consequences of an accident,' due to the control room envelope being inoperable."

The licensee notified the NRC Resident Inspector.


Agreement State
Event Number: 57995
Rep Org: Georgia Radioactive Material Pgm
Licensee: Applied Technical Services, LLC
Region: 1
City: Augusta   State: GA
County:
License #: GA 896-1
Agreement: Y
Docket:
NRC Notified By: John Hays
HQ OPS Officer: Josue Ramirez
Notification Date: 10/21/2025
Notification Time: 15:10 [ET]
Event Date: 10/13/2025
Event Time: 00:00 [EDT]
Last Update Date: 10/21/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Young, Matt (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Grant, Jeffery (IRMOC)
Event Text
AGREEMENT STATE REPORT - LOSS OF CONTROL OF RADIOACTIVE MATERIAL

The following is a summary of information provided by the Georgia Radioactive Material Program via phone and email:

On October 13, 2025, Applied Technical Services, LLC (ATS) shipped a radiography camera containing a sealed source to QSA Global via common carrier overnight delivery. The shipment originated from Augusta, Georgia and was destined for Burlington, Massachusetts.

On October 21, 2025, ATS was notified by QSA Global that they had yet to receive the device. ATS followed up with the common carrier to attempt to locate the device and get further status. Using the package tracking number, it was determined that the package arrived at the common carrier's sorting facility in Memphis, Tennessee on October 13, 2025. After further investigation, the package was located at the common carrier facility and will be shipped to QSA Global.

Camera information:
Manufacturer: QSA Global
Model: 880 Delta
Serial Number: D11255

Source Information:
Model: A424-9
Isotope: Ir-192
Activity: 102.8 Ci (as of 10/21/2025)

GA Incident Number: 110

THIS MATERIAL EVENT CONTAINS A 'Category 2' LEVEL OF RADIOACTIVE MATERIAL

Category 2 sources, if not safely managed or securely protected, could cause permanent injury to a person who handled them, or were otherwise in contact with them, for a short time (minutes to hours). It could possibly be fatal to be close to this amount of unshielded radioactive material for a period of hours to days. These sources are typically used in practices such as industrial gamma radiography, high dose rate brachytherapy and medium dose rate brachytherapy. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Power Reactor
Event Number: 58008
Facility: Dresden
Region: 3     State: IL
Unit: [2] [] []
RX Type: [2] GE-3,[3] GE-3
NRC Notified By: Shawn Kenady
HQ OPS Officer: Ian Howard
Notification Date: 10/27/2025
Notification Time: 08:50 [ET]
Event Date: 10/27/2025
Event Time: 01:17 [CDT]
Last Update Date: 10/27/2025
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
Person (Organization):
Edwards, Rhex (R3DO)
Ziolkowski, Michael (R3DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N N 0 0
Event Text
VALID REACTOR PROTECTION SYSTEM ACTUATION WHILE SHUTDOWN

The following information was provided by the licensee via phone and email:

"At 0117 CDT on 10/27/2025, with Unit 2 in mode 3 at 0 percent power, an actuation of the RPS system occurred during restoration of the scram instrument volume high level bypass switch to normal. The cause of the RPS system actuation was a valid high level in the scram instrument volume. All control rods had been previously inserted and the RPS system automatically initiated a scram signal as designed when the scram instrument volume high level signal was received.

"This event is being reported in accordance with 10 CFR 50.72(b)(3)(iv)(A) as an event that results in a valid actuation of the RPS system.

"There was no impact on the health and safety of the public or plant personnel."

The NRC Resident Inspector has been notified.