Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for October 08, 2025

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
10/07/2025 - 10/08/2025

Agreement State
Event Number: 57945
Rep Org: Illinois Emergency Mgmt. Agency
Licensee: RCM Laboratories, Inc
Region: 3
City: Hinsdale   State: IL
County:
License #: 9223364
Agreement: Y
Docket:
NRC Notified By: Kimberly Stice
HQ OPS Officer: Ernest West
Notification Date: 09/23/2025
Notification Time: 16:23 [ET]
Event Date: 09/23/2025
Event Time: 00:00 [CDT]
Last Update Date: 10/07/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Szwarc, Dariusz (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
Event Text
EN Revision Imported Date: 10/8/2025

EN Revision Text: AGREEMENT STATE REPORT - LOST SOURCE

The following information was provided by the Illinois Emergency Management Agency (the Agency) via email:

"As a result of an ongoing Agency investigation into unresponsive general licensees, the Agency became aware of one (1) generally licensed fluorescence analyzer device containing 40 millicuries of Cd-109 (Cat 4 source) that is missing.

"Reportedly, in 2023, RCM Laboratories Inc (Hinsdale, Il) ceased operation, per a former employee. There is no indication of intentional theft/diversion, rather the result of an office closure and poor accountability.

"The licensee failed to properly transfer or dispose of the device, a Niton LLC XLp-300A (serial number: 24555). The Agency investigated, and per the real estate agency [which owns the building], the building is empty and confirmed no equipment is in the building.

"The quantity of radioactive material involved is reportable immediately to the Agency and the U.S. NRC."

Illinois Event Number: IL250041

* * * UPDATE ON 10/07/2025 AT 1143 EDT FROM GARY FORSEE TO KERBY SCALES * * *

The following update was provided by the Illinois Emergency Management Agency (the Agency) via email:

"On October 2, 2025, the individual previously associated with the general licensee contacted the Agency and provided appropriate documentation showing the device was properly decommissioned and returned to the manufacturer. The device had been moved to another location without appropriate notice to the Agency. Pending no new data, this matter is considered closed."

Notified R3DO (Edwards and Ziolkowski), NMSS Events Notification, and ILTAB via email.

THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Agreement State
Event Number: 57960
Rep Org: Kansas Dept of Health & Environment
Licensee: University of Kansas Hospital Auth
Region: 4
City: Westwood   State: KS
County: Johnson
License #: 18-C801
Agreement: Y
Docket:
NRC Notified By: David Lawrenz
HQ OPS Officer: Jordan Wingate
Notification Date: 09/30/2025
Notification Time: 12:47 [ET]
Event Date: 09/29/2025
Event Time: 00:00 [CDT]
Last Update Date: 09/30/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Vossmar, Patricia (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - MEDICAL EVENT

The following is a summary of the information provided by the Kansas Departments of Health and Environment (Department) via email:

On September 29, 2025, the University of Kansas Hospital Authority reported that a patient had received a seed for localized treatment of a tumor in their breast tissue. The seed was inserted on July 30, 2025. The patient returned the following day, very ill, was evaluated, and found to have an infection. The physician determined that surgery for removal of the seed would need to be delayed, and the seed could not be removed before October 2, 2025. The dose calculation shows that 5 rem total effective dose equivalent will be reached on October 2, 2025. This report is open and more details are expected following a reactive inspection by the Department.

Device: IsoAid Advantage I124A
Source: 200 uCi I-125

KS Report Number: KS2500011

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.


Agreement State
Event Number: 57961
Rep Org: Florida Bureau of Radiation Control
Licensee: Orlando Health
Region: 1
City: Orlando   State: FL
County: Orange
License #: 4333-1
Agreement: Y
Docket:
NRC Notified By: Monroe Cooper
HQ OPS Officer: Jordan Wingate
Notification Date: 09/30/2025
Notification Time: 14:21 [ET]
Event Date: 09/30/2025
Event Time: 00:00 [EDT]
Last Update Date: 09/30/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Warnek, Nicole (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
Event Text
AGREEMENT STATE REPORT - LOST RADIATION SHIELD

The following information was provided by the Florida Bureau of Radiation Control (BRC) via email:

"BRC received notification from Orlando Health on September 30, 2025, that a depleted uranium shield was disposed of alongside its Nuclear Medicine Adac Camera model MCD/AC. It was last accounted for in 2014. The shield was likely disposed of [during] the decommission and removal of the camera. No records of the [shield] removal are available."

FL Incident #: FL25-097

THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Agreement State
Event Number: 57962
Rep Org: Illinois Emergency Mgmt. Agency
Licensee: Team Industrial Services
Region: 3
City: Hammond   State: IL
County: Piatt
License #: IL-01136-01
Agreement: Y
Docket:
NRC Notified By: Gary Forsee
HQ OPS Officer: Jordan Wingate
Notification Date: 10/01/2025
Notification Time: 16:11 [ET]
Event Date: 10/01/2025
Event Time: 14:15 [CDT]
Last Update Date: 10/01/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Ziolkowski, Michael (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - STUCK SOURCE

The following information was provided by the Illinois Emergency Management Agency (Agency) via phone and email:

"The Agency was contacted on October 1, 2025, at 1415 CDT, by the radiation safety officer (RSO) for TEAM Industrial Services to advise of a radiography source stuck in the exposed position at a temporary worksite in Bethalto, IL. The RSO responded to the site, cut the guide tube and was able to place the source in a shielded position by 1500 CDT. No public or occupational exposures are anticipated as a result of this incident, but a reenactment will be independently conducted by Agency staff. Reportedly, the stuck source was caused by a heavy piece of pipe falling on the guide tube. Pending the Agency's investigation, this represents all available information at this time."

Manufacturer: QSA Global
Model #: A424-9
Source: 94 Ci Ir-192

IL Report #: IL250042


Power Reactor
Event Number: 57967
Facility: Clinton
Region: 3     State: IL
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: Jason Vincent
HQ OPS Officer: Ernest West
Notification Date: 10/06/2025
Notification Time: 06:32 [ET]
Event Date: 10/06/2025
Event Time: 03:21 [CDT]
Last Update Date: 10/06/2025
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical
Person (Organization):
Ziolkowski, Michael (R3DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 A/R Y 23 0
Event Text
AUTOMATIC REACTOR SCRAM

The following information was provided by the licensee via phone and email:

"At 0321 CDT on 10/6/2025, with Unit 1 in mode 1 at 23 percent power, the reactor automatically tripped due to reactor water level rising to the reactor protection system auto-scram setpoint, prior to the manual scram being completed. The trip was not complex with all systems responding normally post-trip. The trip occurred as the station was transitioning level control from the motor driven reactor feed pump to the `A' turbine driven reactor feed pump as part of plant startup. Due to the reactor protection system actuation while critical, this event is being reported as a four-hour, non-emergency notification per 10 CFR 50.72(b)(2)(iv)(B).

"Operations responded using emergency operating procedure 1 (reactor pressure vessel control) and stabilized the plant in mode 3. Decay heat is removed by discharging steam to the main condenser using the turbine bypass valves.

"The digital feedwater level control system response is still under investigation.

"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."


Power Reactor
Event Number: 57968
Facility: Surry
Region: 2     State: VA
Unit: [1] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: Scott Satterfield
HQ OPS Officer: Brian P. Smith
Notification Date: 10/06/2025
Notification Time: 08:30 [ET]
Event Date: 10/06/2025
Event Time: 06:27 [EDT]
Last Update Date: 10/07/2025
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(xi) - Offsite Notification
Person (Organization):
Mckown, Louis J (R2DO)
Grant, Jeffery (IR)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 100
2 N Y 100 100
Event Text
EN Revision Imported Date: 10/7/2025

EN Revision Text: OFFSITE NOTIFICATION DUE TO ONSITE FATALITY

The following information was provided by the licensee via phone and email:

"On October 6, 2025, at 0627 EDT, a notification to the Occupational Safety and Health Administration (OSHA) was initiated due to a Dominion employee experiencing a non-work-related medical event that resulted in the employee passing. When the issue was identified, the station first aid team responded to administer first aid. Upon arrival, the employee was nonresponsive with no pulse. The employee was pronounced deceased on site at 0627 EDT. A report to OSHA will be made in accordance with federal requirements. This event is reportable to the NRC per 10 CFR 50.72(b)(2)(xi) since another government agency will be notified of this fatality.

"The employee was in the plant protected area and was not contaminated.

"The NRC Resident Inspector has been notified."


Power Reactor
Event Number: 57969
Facility: Salem
Region: 1     State: NJ
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: Mike Hasenbein
HQ OPS Officer: Robert A. Thompson
Notification Date: 10/06/2025
Notification Time: 12:20 [ET]
Event Date: 10/06/2025
Event Time: 08:33 [EDT]
Last Update Date: 10/06/2025
Emergency Class: Non Emergency
10 CFR Section:
26.719 - Fitness For Duty
Person (Organization):
Young, Matt (R1DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 100
2 N Y 100 100
Event Text
FITNESS FOR DUTY EVENT

The following information was provided by the licensee via phone:

A licensee non-licensed supervisor failed a random fitness-for-duty test. The individual was not on-site at the time of the determination. The individual's access has been revoked.

The NRC Resident Inspector has been notified.