Event Notification Report for September 26, 2025

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
09/25/2025 - 09/26/2025

EVENT NUMBERS
5795557956
Agreement State
Event Number: 57955
Rep Org: Virginia Rad Materials Program
Licensee: Hillis-Carnes Engineering Associates Inc.
Region: 1
City: Chesterfield   State: VA
County: Chesterfield
License #: 107-453-1
Agreement: Y
Docket:
NRC Notified By: Sheila Nelson
HQ OPS Officer: Josue Ramirez
Notification Date: 09/26/2025
Notification Time: 14:05 [ET]
Event Date: 09/26/2025
Event Time: 08:20 [EDT]
Last Update Date: 09/26/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Lilliendahl, Jon (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - VEHICLE CARRYING NUCLEAR GAUGE INVOLVED IN AN ACCIDENT

The following information was received via email from the Virginia Radiation Materials Program (VRMP):

"At approximately 1020 EDT on September 26, 2025, VRMP was notified of an automobile accident involving a vehicle carrying a portable nuclear gauge. At approximately 0820 EDT on September 26, 2025, a Troxler model 3430 portable nuclear density/moisture gauge (S/N 36802), containing 9 mCi of Cs-137 and 44 mCi of Am-241, was in a vehicle that was struck from behind in Chesterfield, VA. While a relatively minor accident, once it was noted that the radioactive material was present, the Chesterfield Hazardous Material team responded.

"The vehicle was isolated (300-meter perimeter), and the highway was shut down for approximately 2 hours. The authorized user notified his supervisor (assistant radiation safety officer (RSO), who then notified the RSO. The [assistant RSO] went to the site to evaluate the gauge. She notified VRMP. Per the assistant RSO, the gauge was appropriately blocked, braced, and secured in the trunk of the car when it was rear-ended. The car sustained damage but there was no apparent damage to the case or gauge.

"The licensee and the hazmat team surveyed the case/gauge and readings were within acceptable ranges indicating no source exposure. The case/gauge was moved to another of the licensee's vehicles and returned to the licensee's storage facility for further evaluation. There were no injuries as a result of the accident and no radiation exposures.

"VRMP will follow up with an investigation."

Virginia event report number: VA250004


Agreement State
Event Number: 57956
Rep Org: Florida Bureau of Radiation Control
Licensee: Citrus Cardiology Consultants
Region: 1
City: Crystal River   State: FL
County:
License #: 4829-5
Agreement: Y
Docket:
NRC Notified By: Mark Seidensticker
HQ OPS Officer: Josue Ramirez
Notification Date: 09/26/2025
Notification Time: 16:34 [ET]
Event Date: 09/26/2025
Event Time: 16:34 [EDT]
Last Update Date: 09/26/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Lilliendahl, Jon (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
Event Text
AGREEMENT STATE REPORT - LOST SOURCE

The following information was provided by the Florida Bureau of Radiation Control (BRC) via email:

"The radiation safety officer (RSO) with Citrus Cardiology Consultants in Crystal River, Florida, called the BRC this afternoon regarding a lost 94.6 microcurie Ge-68 source, S/N 2509-89. The RSO said the source is used in a BQC Styrofoam pillow for tuning a positron emission tomography (PET) camera. The RSO said an installer for their new PET camera, out of Houston, Texas, used the Ge-68 source with a Styrofoam pillow to tune the new PET and left the source and pillow in their hot lab. The pillow is approximately two feet long and crescent shaped.

"The RSO said nobody associated with the hot lab saw the BQC pillow, the source, or the box it supposedly came in. The installer has reciprocity with Florida. The company is Catalyst MedTech in Houston, Texas."

FL incident number: FL25-095

THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf