Event Notification Report for September 04, 2025
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
09/03/2025 - 09/04/2025
Agreement State
Event Number: 57886
Rep Org: New Mexico Rad Control Program
Licensee: Chino Mines Company
Region: 4
City: Bayard State: NM
County:
License #: GA 045-50
Agreement: Y
Docket:
NRC Notified By: Bobby Bicknell
HQ OPS Officer: Robert A. Thompson
Notification Date: 08/27/2025
Notification Time: 13:12 [ET]
Event Date: 08/26/2025
Event Time: 00:00 [MDT]
Last Update Date: 08/27/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Dixon, John (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - FIXED GAUGE SHUTTER MISSING
The following is a summary of information provided by the New Mexico Radiation Control Bureau via phone and email:
During a routine inspection, the licensee discovered that the normally open shutter on a fixed gauge installed on a pipeline was missing. The gauge remains installed and is operating normally. All planned maintenance in the area of the gauge has been suspended. The licensee has been instructed to obtain the assistance of properly trained and qualified personnel to assist with corrective actions.
Gauge: Texas Nuclear model 5190, s/n B3309
Source: Cs-137, 100 mCi
Agreement State
Event Number: 57887
Rep Org: Kentucky Dept of Radiation Control
Licensee: University of Kentucky
Region: 1
City: Lexington State: KY
County:
License #: 202-049-22
Agreement: Y
Docket:
NRC Notified By: Russell Hestand
HQ OPS Officer: Robert A. Thompson
Notification Date: 08/27/2025
Notification Time: 15:26 [ET]
Event Date: 08/22/2025
Event Time: 00:00 [CDT]
Last Update Date: 08/27/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Carfang, Erin (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - MEDICAL EVENT
The following information was provided by the Radiation Health Branch of the Kentucky Department for Public Health and Safety via email:
"On August 26, 2025, the University of Kentucky (UK) Health Center radiation safety officer became aware of a situation that represents what UK believes are a series of possible medical events which occurred from August 22 to August 25, 2025, related to nuclear medicine administrations requiring written directives. Within this date range, a new faculty physician who was in the process of becoming approved as an authorized user (AU) through the UK radiation safety committee (RSC) signed 5 written directives (3 for diagnostic I-131 procedures with a nominal activity of 5 mCi, and 2 for Lu-177 therapy at a 100 mCi activity) despite not having yet received approval under the UK medical broad scope license from the UK RSC. The cases have all been reviewed by a senior AU and no patient harm has been identified. The physician in question has since received approval from the UK RSC. Notifications are in process as required.
"This event is under investigation. University of Kentucky will complete an assessment and implement corrective actions.
"The written report will follow as required in 15 days."
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
Fuel Cycle Facility
Event Number: 57888
Facility: American Centrifuge Plant
RX Type: Uranium Enrichment Facility
Comments:
Region: 2
City: Piketon State: OH
County: Pike
License #: SNM-2011
Docket: 70-7004
NRC Notified By: Jeff Spires
HQ OPS Officer: Josue Ramirez
Notification Date: 08/27/2025
Notification Time: 17:11 [ET]
Event Date: 08/27/2025
Event Time: 14:50 [EDT]
Last Update Date: 08/27/2025
Emergency Class: Non Emergency
10 CFR Section:
PART 70 APP A (c) - Offsite Notification/News Rel
Person (Organization):
Bacon, Daniel (R2DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
CONCURRENT REPORT FOR OFFSITE NOTIFICATION
The following is a summary of information provided by the licensee via phone and email:
Centrus American Centrifuge Operating (ACO) received notification from a Fluor-BWXT Portsmouth (FBP) environmental technician supervisor that the chlorine level at outfall '013' was at 0.063 mg/L. This exceeds the National Pollutant Discharge Elimination System permit limit on total chlorine at outfall '013' of 0.05 mg/L. Centrus ACO notified the Ohio Environmental Protection Agency at 1450 EDT.
Elevated chlorine levels at outfall '013' were initially noted and reported on August 18, 2025, under EN 57874. Centrus ACO has since determined that a sanitary line break that went into a holding pond is the cause of the elevated chlorine levels. Elevated chlorine levels observed today are attributed to residual chlorine upstream of the outfall.
This report is in accordance with condition notification #12816.
The NRC regional office was notified.
Non-Agreement State
Event Number: 57889
Rep Org: Weyerhaeuser
Licensee: Weyerhaeuser
Region: 4
City: Columbia Falls State: MT
County:
License #: 25-15644-01
Agreement: N
Docket:
NRC Notified By: Hunter Kent
HQ OPS Officer: Sam Colvard
Notification Date: 08/28/2025
Notification Time: 17:40 [ET]
Event Date: 08/28/2025
Event Time: 09:48 [MDT]
Last Update Date: 08/28/2025
Emergency Class: Non Emergency
10 CFR Section:
30.50(b)(2) - Safety Equipment Failure
Person (Organization):
Dixon, John (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
STUCK OPEN SHUTTER
The following is a summary of information provided by the licensee via phone:
On August 28, 2025, an authorized user notified the radiation safety officer that the shutter of a fixed Ohmart/Vega SHF1A source holder with a 50 mCi Cs-137 source could not be closed while preparing for a routine inspection of a process vessel. The entrance to the process vessel was barricaded. A do-not-operate tag was placed on the source holder shutter handle. Communication of the event to facility personnel is in progress. The manufacturer stated that the model of source holder is no longer in production and must be replaced. There were no overexposures due to this event.
Agreement State
Event Number: 57890
Rep Org: Texas Dept of State Health Services
Licensee: Exxon-Mobil Corporation
Region: 4
City: Mont Belvieu State: TX
County:
License #: L 03119
Agreement: Y
Docket:
NRC Notified By: Art Tucker
HQ OPS Officer: Robert A. Thompson
Notification Date: 08/28/2025
Notification Time: 21:28 [ET]
Event Date: 08/27/2025
Event Time: 00:00 [CDT]
Last Update Date: 08/28/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Dixon, John (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - STUCK OPEN GAUGE SHUTTER
The following information was provided by the Texas Department of State Health Services (the Department) via email:
"On August 28, 2025, the Department was notified that the shutter on a Vega SHF2C-45 nuclear gauge had failed in the open position during routine testing. The gauge contains a 500 mCi cesium-137 source. Open is the normal position for the shutter. The licensee reported there is no risk of additional radiation exposure to members of the general public or radiation workers, due to this on/off mechanism failure. Additional information will be provided as it is received in accordance with SA-300."
Texas incident number: 10219
NMED number: TX250039