Event Notification Report for August 07, 2025
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
08/06/2025 - 08/07/2025
Agreement State
Event Number: 57842
Rep Org: Wisconsin Radiation Protection
Licensee: Aspirus Wausau Hospital
Region: 3
City: Wausau State: WI
County:
License #: 073-1342-01
Agreement: Y
Docket:
NRC Notified By: Kyle Walton
HQ OPS Officer: Ossy Font
Licensee: Aspirus Wausau Hospital
Region: 3
City: Wausau State: WI
County:
License #: 073-1342-01
Agreement: Y
Docket:
NRC Notified By: Kyle Walton
HQ OPS Officer: Ossy Font
Notification Date: 07/31/2025
Notification Time: 14:47 [ET]
Event Date: 07/31/2025
Event Time: 00:00 [CDT]
Last Update Date: 07/31/2025
Notification Time: 14:47 [ET]
Event Date: 07/31/2025
Event Time: 00:00 [CDT]
Last Update Date: 07/31/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Hills, David (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Hills, David (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - MEDICAL EVENT
The following information was provided by the Wisconsin Department of Health Services (the Department) via email:
"On July 31, 2025, the licensee was treating the third of five fractions for a gynecological cylinder HDR (high dose rate) treatment. The authorized user placed the cylinder prior to treatment and confirmed that they believed it was snug and fully inserted. The licensee also utilized briefs with Velcro straps to hold the cylinder in place. Following the completion of the treatment, the authorized user identified that the cylinder was no longer snug, and that it had shifted by up to one centimeter. It is unclear whether the shift happened during or after treatment. The prescribed dose was 6 Gy for the fraction. The licensee performed a dose reconstruction and determined that if the cylinder had shifted immediately, the cervix would have only received 2.6 Gy (44 percent) of the dose. The licensee believes that the shift would not have resulted in a dose to other organs above regulatory limits, and that the completion of the remaining fractions will result in the desired clinical outcome. The authorized user notified the patient immediately. The Department will perform an investigation."
Wisconsin Item Number: WI250007
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
The following information was provided by the Wisconsin Department of Health Services (the Department) via email:
"On July 31, 2025, the licensee was treating the third of five fractions for a gynecological cylinder HDR (high dose rate) treatment. The authorized user placed the cylinder prior to treatment and confirmed that they believed it was snug and fully inserted. The licensee also utilized briefs with Velcro straps to hold the cylinder in place. Following the completion of the treatment, the authorized user identified that the cylinder was no longer snug, and that it had shifted by up to one centimeter. It is unclear whether the shift happened during or after treatment. The prescribed dose was 6 Gy for the fraction. The licensee performed a dose reconstruction and determined that if the cylinder had shifted immediately, the cervix would have only received 2.6 Gy (44 percent) of the dose. The licensee believes that the shift would not have resulted in a dose to other organs above regulatory limits, and that the completion of the remaining fractions will result in the desired clinical outcome. The authorized user notified the patient immediately. The Department will perform an investigation."
Wisconsin Item Number: WI250007
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
Agreement State
Event Number: 57843
Rep Org: Florida Bureau of Radiation Control
Licensee: Adventist Health Systems
Region: 1
City: Altamonte State: FL
County:
License #: 2897-1
Agreement: Y
Docket:
NRC Notified By: Mark Seidensticker
HQ OPS Officer: Kerby Scales
Licensee: Adventist Health Systems
Region: 1
City: Altamonte State: FL
County:
License #: 2897-1
Agreement: Y
Docket:
NRC Notified By: Mark Seidensticker
HQ OPS Officer: Kerby Scales
Notification Date: 07/31/2025
Notification Time: 17:11 [ET]
Event Date: 07/08/2025
Event Time: 00:00 [EDT]
Last Update Date: 07/31/2025
Notification Time: 17:11 [ET]
Event Date: 07/08/2025
Event Time: 00:00 [EDT]
Last Update Date: 07/31/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Bickett, Carey (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
Drake, James (R4DO)
Bickett, Carey (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
Drake, James (R4DO)
AGREEMENT STATE REPORT - LOST SOURCE
The following information was provided by the Florida Bureau of Radiation Control via email:
"Adventist Health Systems radiation safety officer (RSO) called today at 1603 EDT to report a lost source while in transit with [common carrier]. The source was a rod source of Gd-153 being shipped in a lead sleeve. The activity of the Gd-153 source at the beginning of July 2025 was 0.04 mCi. The RSO was first notified on July 8, 2025, of the source not arriving at the destination of Eckert and Zeigler in Burbank, California. An employee with Eckert and Zeigler confirmed the box was empty when received on July 7, 2025. There was no source or lead sleeve in the box. They took one picture of the box, then disposed of the box. The RSO has been investigating this incident since July 8. He said the [common carrier] told him that the box was weighed at the midpoint of the shipment in Memphis and the box weight was unchanged from when it left Orlando. He also said anti-tamper tape was placed on the box, but it was unknown if the tape was intact upon arrival at Eckert and Zeigler. There is an ongoing investigation between Adventist Health and the [common carrier]."
Florida Incident Number: FL25-074
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following information was provided by the Florida Bureau of Radiation Control via email:
"Adventist Health Systems radiation safety officer (RSO) called today at 1603 EDT to report a lost source while in transit with [common carrier]. The source was a rod source of Gd-153 being shipped in a lead sleeve. The activity of the Gd-153 source at the beginning of July 2025 was 0.04 mCi. The RSO was first notified on July 8, 2025, of the source not arriving at the destination of Eckert and Zeigler in Burbank, California. An employee with Eckert and Zeigler confirmed the box was empty when received on July 7, 2025. There was no source or lead sleeve in the box. They took one picture of the box, then disposed of the box. The RSO has been investigating this incident since July 8. He said the [common carrier] told him that the box was weighed at the midpoint of the shipment in Memphis and the box weight was unchanged from when it left Orlando. He also said anti-tamper tape was placed on the box, but it was unknown if the tape was intact upon arrival at Eckert and Zeigler. There is an ongoing investigation between Adventist Health and the [common carrier]."
Florida Incident Number: FL25-074
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Power Reactor
Event Number: 57850
Facility: Browns Ferry
Region: 2 State: AL
Unit: [1] [2] [3]
RX Type: [1] GE-4,[2] GE-4,[3] GE-4
NRC Notified By: Alexander Neumann
HQ OPS Officer: Jon Lilliendahl
Region: 2 State: AL
Unit: [1] [2] [3]
RX Type: [1] GE-4,[2] GE-4,[3] GE-4
NRC Notified By: Alexander Neumann
HQ OPS Officer: Jon Lilliendahl
Notification Date: 08/05/2025
Notification Time: 15:28 [ET]
Event Date: 06/10/2025
Event Time: 18:10 [CDT]
Last Update Date: 08/05/2025
Notification Time: 15:28 [ET]
Event Date: 06/10/2025
Event Time: 18:10 [CDT]
Last Update Date: 08/05/2025
Emergency Class: Non Emergency
10 CFR Section:
50.73(a)(1) - Invalid Specif System Actuation
10 CFR Section:
50.73(a)(1) - Invalid Specif System Actuation
Person (Organization):
Davis, Bradley (R2DO)
Davis, Bradley (R2DO)
Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
---|---|---|---|---|---|---|
1 | N | Y | 100 | 83 | ||
2 | N | Y | 100 | 100 | ||
3 | N | Y | 100 | 0 |
60-DAY OPTIONAL TELEPHONIC NOTIFICATION FOR INVALID CONTAINMENT ISOLATION
The following information was provided by the licensee via phone and email:
"This 60-day telephone notification is being made per the reporting requirements specified by 10 CFR 50.73(a)(2)(iv)(A) and 10 CFR 50.73(a)(1) to describe an invalid actuation of a general containment isolation signal affecting more than one system.
"On June 10, 2025, Unit 2 operations personnel received an `A' channel half scram and entered 2-AOI-99-1. Motor generator set 2A was shut down and reactor protection system `A' was swapped to alternate. This resulted in primary containment isolation system (PCIS) groups 2, 3, 6, and 8 isolations, and initiation of standby gas treatment (SGT) trains `A', `B', and `C' and control room emergency ventilation system (CREV) train `A'. All affected safety systems responded as expected.
"Plant conditions which initiate PCIS groups 2 and 8 actuations are reactor vessel low water level and high drywell pressure. Plant conditions which initiate PCIS group 3 actuations, are reactor vessel low water level and reactor water cleanup area high temperature.
"Plant conditions which initiate PCIS group 6, CREV and SGT actuations, are reactor vessel low water level, high drywell pressure, or reactor building ventilation exhaust high radiation (reactor zone or refuel zone). At the time of the event, these conditions did not exist; the actuation was due to a loss of power and not due to a low reactor water level or drywell pressure. Therefore, the actuation of the PCIS, CREV, and SGT was invalid.
"Upon investigation, the 2A2 circuit protector was found to have charred wire on the top right lug. The terminal block was replaced.
"There were no safety consequences or impact to the health and safety of the public as a result of this event.
"This event was entered into the corrective action program as condition report 2019406."
The following information was provided by the licensee via phone and email:
"This 60-day telephone notification is being made per the reporting requirements specified by 10 CFR 50.73(a)(2)(iv)(A) and 10 CFR 50.73(a)(1) to describe an invalid actuation of a general containment isolation signal affecting more than one system.
"On June 10, 2025, Unit 2 operations personnel received an `A' channel half scram and entered 2-AOI-99-1. Motor generator set 2A was shut down and reactor protection system `A' was swapped to alternate. This resulted in primary containment isolation system (PCIS) groups 2, 3, 6, and 8 isolations, and initiation of standby gas treatment (SGT) trains `A', `B', and `C' and control room emergency ventilation system (CREV) train `A'. All affected safety systems responded as expected.
"Plant conditions which initiate PCIS groups 2 and 8 actuations are reactor vessel low water level and high drywell pressure. Plant conditions which initiate PCIS group 3 actuations, are reactor vessel low water level and reactor water cleanup area high temperature.
"Plant conditions which initiate PCIS group 6, CREV and SGT actuations, are reactor vessel low water level, high drywell pressure, or reactor building ventilation exhaust high radiation (reactor zone or refuel zone). At the time of the event, these conditions did not exist; the actuation was due to a loss of power and not due to a low reactor water level or drywell pressure. Therefore, the actuation of the PCIS, CREV, and SGT was invalid.
"Upon investigation, the 2A2 circuit protector was found to have charred wire on the top right lug. The terminal block was replaced.
"There were no safety consequences or impact to the health and safety of the public as a result of this event.
"This event was entered into the corrective action program as condition report 2019406."
Power Reactor
Event Number: 57854
Facility: Surry
Region: 2 State: VA
Unit: [1] [] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: Richard Post
HQ OPS Officer: Ernest West
Region: 2 State: VA
Unit: [1] [] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: Richard Post
HQ OPS Officer: Ernest West
Notification Date: 08/06/2025
Notification Time: 21:17 [ET]
Event Date: 08/06/2025
Event Time: 18:47 [EDT]
Last Update Date: 08/06/2025
Notification Time: 21:17 [ET]
Event Date: 08/06/2025
Event Time: 18:47 [EDT]
Last Update Date: 08/06/2025
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical 50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical 50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
Person (Organization):
Davis, Bradley (R2DO)
Davis, Bradley (R2DO)
Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
---|---|---|---|---|---|---|
1 | A/R | Y | 100 | 0 |
AUTOMATIC REACTOR TRIP
The following information was provided by the licensee via phone and email:
"Surry Unit 1 reactor automatically tripped at 1847 EDT on August 6, 2025, due to a spurious actuation of high consequence limiting safeguards train `B' [due to a false high containment pressure trip signal]. Reactor coolant temperature is being maintained at 547 degrees Fahrenheit on the main steam dumps with main feedwater supplying the steam generators.
"All systems operated as required. The trip was uncomplicated and all control rods fully inserted into the core. Reactor protection system, emergency core cooling system, auxiliary feedwater system, emergency diesel generators, phase I and phase II containment isolation signals all actuated as designed. Offsite power remains available. There is no impact to Surry Unit 2.
"This notification is being made pursuant to 10 CFR 50.72(b)(2)(iv)(B) for 4-hour notification of reactor protection system activation and 10 CFR 50.72(b)(3)(iv)(A) for 8-hour notification of specified system actuation. The NRC Resident Inspector has been notified via cell phone."
The following information was provided by the licensee via phone and email:
"Surry Unit 1 reactor automatically tripped at 1847 EDT on August 6, 2025, due to a spurious actuation of high consequence limiting safeguards train `B' [due to a false high containment pressure trip signal]. Reactor coolant temperature is being maintained at 547 degrees Fahrenheit on the main steam dumps with main feedwater supplying the steam generators.
"All systems operated as required. The trip was uncomplicated and all control rods fully inserted into the core. Reactor protection system, emergency core cooling system, auxiliary feedwater system, emergency diesel generators, phase I and phase II containment isolation signals all actuated as designed. Offsite power remains available. There is no impact to Surry Unit 2.
"This notification is being made pursuant to 10 CFR 50.72(b)(2)(iv)(B) for 4-hour notification of reactor protection system activation and 10 CFR 50.72(b)(3)(iv)(A) for 8-hour notification of specified system actuation. The NRC Resident Inspector has been notified via cell phone."
Agreement State
Event Number: 57646
Rep Org: Texas Dept of State Health Services
Licensee: High Mountain Inspection
Region: 4
City: Odessa State: TX
County:
License #: L-07197
Agreement: Y
Docket:
NRC Notified By: Bruce Hammond
HQ OPS Officer: Robert A. Thompson
Licensee: High Mountain Inspection
Region: 4
City: Odessa State: TX
County:
License #: L-07197
Agreement: Y
Docket:
NRC Notified By: Bruce Hammond
HQ OPS Officer: Robert A. Thompson
Notification Date: 04/04/2025
Notification Time: 17:10 [ET]
Event Date: 04/04/2025
Event Time: 00:00 [CDT]
Last Update Date: 08/07/2025
Notification Time: 17:10 [ET]
Event Date: 04/04/2025
Event Time: 00:00 [CDT]
Last Update Date: 08/07/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Agrawal, Ami (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Agrawal, Ami (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
EN Revision Imported Date: 8/8/2025
EN Revision Text: AGREEMENT STATE REPORT - POTENTIAL OVEREXPOSURE
The following information was provided by the Texas Department of State Health Services (the Department) via phone and email:
"On April 4, 2025, the Department was notified by the licensee of a telephonic overexposure report they received from their dosimetry provider. The licensee radiation safety officer stated the report had one of their employees with an exposure of 7.7 rem for the month of February 2025. The licensee had other readings (pocket dosimeters) that did not match this level of exposure. The licensee removed the employee from the work environment until the dose can be confirmed. The employee affected is an assistant, and neither of the other two radiographers had any exposure near this level. The licensee is still investigating.
"More information will be made available according to SA-300 requirements."
Texas incident number: 10189
NMED number: TX250022
* * * RETRACTION ON 08/07/2025 AT 1600 EDT FROM TEXAS DEPARTMENT OF STATE HEALTH SERVICES TO JORDAN WINGATE * * *
The following retraction was provided by the Texas Department of State Health Services (the Department) via email:
"After review by the radiation safety officer (RSO) and corporate RSO it was determined to be an anomaly in the processing of the dosimeter. The person was not near anything capable of that [level of] exposure and no one the person worked with was exposed to anything above expected numbers. The licensee assigned a dose of 285 mR for the period in question and notified the dosimetry provider."
Notified R4DO (Bywater) and NMSS Events Notifications (email).
EN Revision Text: AGREEMENT STATE REPORT - POTENTIAL OVEREXPOSURE
The following information was provided by the Texas Department of State Health Services (the Department) via phone and email:
"On April 4, 2025, the Department was notified by the licensee of a telephonic overexposure report they received from their dosimetry provider. The licensee radiation safety officer stated the report had one of their employees with an exposure of 7.7 rem for the month of February 2025. The licensee had other readings (pocket dosimeters) that did not match this level of exposure. The licensee removed the employee from the work environment until the dose can be confirmed. The employee affected is an assistant, and neither of the other two radiographers had any exposure near this level. The licensee is still investigating.
"More information will be made available according to SA-300 requirements."
Texas incident number: 10189
NMED number: TX250022
* * * RETRACTION ON 08/07/2025 AT 1600 EDT FROM TEXAS DEPARTMENT OF STATE HEALTH SERVICES TO JORDAN WINGATE * * *
The following retraction was provided by the Texas Department of State Health Services (the Department) via email:
"After review by the radiation safety officer (RSO) and corporate RSO it was determined to be an anomaly in the processing of the dosimeter. The person was not near anything capable of that [level of] exposure and no one the person worked with was exposed to anything above expected numbers. The licensee assigned a dose of 285 mR for the period in question and notified the dosimetry provider."
Notified R4DO (Bywater) and NMSS Events Notifications (email).
Agreement State
Event Number: 57845
Rep Org: Georgia Radioactive Material Pgm
Licensee: Doctors Hospital
Region: 1
City: Augusta State: GA
County:
License #: GA 615-1
Agreement: Y
Docket:
NRC Notified By: Anastasia Bennett
HQ OPS Officer: Jon Lilliendahl
Licensee: Doctors Hospital
Region: 1
City: Augusta State: GA
County:
License #: GA 615-1
Agreement: Y
Docket:
NRC Notified By: Anastasia Bennett
HQ OPS Officer: Jon Lilliendahl
Notification Date: 08/01/2025
Notification Time: 16:29 [ET]
Event Date: 07/07/2025
Event Time: 00:00 [EDT]
Last Update Date: 08/01/2025
Notification Time: 16:29 [ET]
Event Date: 07/07/2025
Event Time: 00:00 [EDT]
Last Update Date: 08/01/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Bickett, Carey (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Bickett, Carey (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - MEDICAL EVENT
The following report was provided by the Georgia Radioactive Materials Program via email:
"The licensee called and stated that during a post treatment review with the physician conducted today, it was identified that a patient receiving yttrium-90 therapy on July 7, 2025, was underexposed due to a kink in the catheter. The prescribed dose was 0.439 GBq (11.853 mCi), but the administered dose was determined to be 0.177 GBq (4.779 mCi). This represents a 40.32 percent deviation from the prescribed dose, which exceeds the 20 percent reporting threshold. Upon further review of the patient's treatment history, it was additionally discovered that two prior underdosing events occurred on August 20, 2024, and September 30, 2024. Both events were also attributed to catheter kinking and involved dose delivery to small treatment volumes in limited target areas. [The licensee] stated that a formal written report detailing all three underdosing events, along with supporting documentation, will be submitted via email on Monday, August 4, 2025."
Georgia Incident Number: 105
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
The following report was provided by the Georgia Radioactive Materials Program via email:
"The licensee called and stated that during a post treatment review with the physician conducted today, it was identified that a patient receiving yttrium-90 therapy on July 7, 2025, was underexposed due to a kink in the catheter. The prescribed dose was 0.439 GBq (11.853 mCi), but the administered dose was determined to be 0.177 GBq (4.779 mCi). This represents a 40.32 percent deviation from the prescribed dose, which exceeds the 20 percent reporting threshold. Upon further review of the patient's treatment history, it was additionally discovered that two prior underdosing events occurred on August 20, 2024, and September 30, 2024. Both events were also attributed to catheter kinking and involved dose delivery to small treatment volumes in limited target areas. [The licensee] stated that a formal written report detailing all three underdosing events, along with supporting documentation, will be submitted via email on Monday, August 4, 2025."
Georgia Incident Number: 105
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
Agreement State
Event Number: 57846
Rep Org: California Radiation Control Prgm
Licensee: Earth Strata Geotechnical Services, Inc.
Region: 4
City: Temecula State: CA
County:
License #: 7612-33
Agreement: Y
Docket:
NRC Notified By: Donald Oesterle
HQ OPS Officer: Jon Lilliendahl
Licensee: Earth Strata Geotechnical Services, Inc.
Region: 4
City: Temecula State: CA
County:
License #: 7612-33
Agreement: Y
Docket:
NRC Notified By: Donald Oesterle
HQ OPS Officer: Jon Lilliendahl
Notification Date: 08/01/2025
Notification Time: 19:20 [ET]
Event Date: 08/01/2025
Event Time: 00:00 [PDT]
Last Update Date: 08/01/2025
Notification Time: 19:20 [ET]
Event Date: 08/01/2025
Event Time: 00:00 [PDT]
Last Update Date: 08/01/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - DAMAGED GAUGE
The following information was provided by the California Radiation Control Program via email:
"[The licensee] contacted the California Department of Emergency Services to report a moisture density gauge was run over at a worksite. The gauge was a CPN MC-3, S/N M30019316 (10 mCi cesium-137, 50mCi americium-241/beryllium). After placing the gauge with the cesium-137 source in the locked and shielded position on the ground, the operator went to retrieve some equipment from his vehicle when the bulldozer ran over the gauge snapping the source rod off and damaging the plastic housing on the top of the gauge. The bottom of the gauge was intact, and the americium-241/beryllium source was still attached and undamaged. The licensee was instructed to place the gauge in the transport case and wait until the Riverside County Department of Environmental Health inspector arrived at the scene.
"Upon arrival, the inspector performed a radiation survey (model and serial number not reported) and found there were no significant radiation levels above background. The gauge will be transported to Maurer Technical Services for disposal. The investigation into the incident by the California Department of Public Health is ongoing."
California 5010 Number: 080125
The following information was provided by the California Radiation Control Program via email:
"[The licensee] contacted the California Department of Emergency Services to report a moisture density gauge was run over at a worksite. The gauge was a CPN MC-3, S/N M30019316 (10 mCi cesium-137, 50mCi americium-241/beryllium). After placing the gauge with the cesium-137 source in the locked and shielded position on the ground, the operator went to retrieve some equipment from his vehicle when the bulldozer ran over the gauge snapping the source rod off and damaging the plastic housing on the top of the gauge. The bottom of the gauge was intact, and the americium-241/beryllium source was still attached and undamaged. The licensee was instructed to place the gauge in the transport case and wait until the Riverside County Department of Environmental Health inspector arrived at the scene.
"Upon arrival, the inspector performed a radiation survey (model and serial number not reported) and found there were no significant radiation levels above background. The gauge will be transported to Maurer Technical Services for disposal. The investigation into the incident by the California Department of Public Health is ongoing."
California 5010 Number: 080125