Event Notification Report for March 27, 2025

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
03/26/2025 - 03/27/2025

Power Reactor
Event Number: 57633
Facility: Palo Verde
Region: 4     State: AZ
Unit: [1] [] []
RX Type: [1] CE,[2] CE,[3] CE
NRC Notified By: Arthur Tadiar
HQ OPS Officer: Jon Lilliendahl
Notification Date: 03/28/2025
Notification Time: 07:38 [ET]
Event Date: 03/28/2025
Event Time: 01:06 [MST]
Last Update Date: 03/28/2025
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(v)(D) - Accident Mitigation
Person (Organization):
Deese, Rick (R4DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
EN Revision Imported Date: 4/2/2025

EN Revision Text: HIGH PRESSURE SAFETY INJECTION PUMP INOPERABLE

The following information was provided by the licensee via phone and email:

"On 3/28/2025 at 0106 MST, Palo Verde Generating Station Unit 1 entered Technical Specification Limiting Condition for Operation (LCO) 3.0.3 due to discovering `A' essential chiller (EC) oil temperature at 80 degrees Fahrenheit, which is below the operability limit of 120 degrees Fahrenheit. `A' EC inoperable rendered the `A' high pressure safety injection (HPSI) pump inoperable. At the time of discovery, `B' HPSI was inoperable due to recirculating the refueling water tank for chemistry purposes (LCO 3.5.3 condition B entered on 3/27/2025 at 2127 MST). This resulted in inoperability for both trains of HPSI, leading to a loss of the HPSI safety function.

"On 3/28/2025 at 0115 MST, `B' HPSI was restored to operable condition, LCO 3.0.3 was exited, and the loss of safety function was restored.

"There were no power reductions (control rod insertions or boron concentration changes). The event did not result in any challenges to the fission product barrier or result in any release of radioactive materials. Unit 2 and 3 remained at 100%.

"NRC resident has been notified of the event."


Power Reactor
Event Number: 57636
Facility: Brunswick
Region: 2     State: NC
Unit: [2] [] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: Charlie Brookshire
HQ OPS Officer: Rodney Clagg
Notification Date: 03/28/2025
Notification Time: 19:07 [ET]
Event Date: 03/28/2025
Event Time: 14:09 [EDT]
Last Update Date: 03/28/2025
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
Person (Organization):
Pearson, Laura (R2DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 1 Startup 1 Startup
Event Text
EN Revision Imported Date: 4/2/2025

EN Revision Text: AUTOMATIC ACTUATION OF CONTAINMENT ISOLATION VALVES

The following information was provided by the licensee via phone and email:

"At approximately 1409 EDT on March 28, 2025, with Unit 2 in mode 2 at approximately 1 percent power during reactor startup, an actuation of group 1 primary containment isolation valves (PCIVs) (i.e., main steam line, main steam line drain, and reactor water sample line isolation valves) occurred during performance of the Unit 2 turbine control/stop valves tightness test procedure. The group 1 PCIV actuation resulted when the turbine stop valves were opened (with control valves remaining closed) while main condenser vacuum was below 10 inches Hg [inches of Mercury]. The PCIVs automatically closed as designed when the group 1 actuation signal was received.

"This event is being reported in accordance with 10 CFR 50.72(b)(3)(iv)(A) as an event that resulted in a valid actuation of containment isolation valves in more than one system.

"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."


Agreement State
Event Number: 57635
Rep Org: Texas Dept of State Health Services
Licensee: unknown
Region: 4
City: Texas City   State: TX
County:
License #: Unknown
Agreement: Y
Docket:
NRC Notified By: Arthur Tucker
HQ OPS Officer: Rodney Clagg
Notification Date: 03/28/2025
Notification Time: 16:25 [ET]
Event Date: 03/28/2025
Event Time: 15:25 [CDT]
Last Update Date: 03/28/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Deese, Rick (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - FOUND SOURCE
The following information was provided by the Texas Department of State Health Services (the Department) via phone and email:

"On March 28, 2025, the Department was contacted by the radiation safety officer (RSO) of an industrial radiography company licensed in the state of Texas. The RSO stated they were contacted by a local fire chief about a device found on the side of the road in Texas City, Texas. The RSO went to the location and identified the device as a Troxler model 3411-B moisture density gauge. The RSO stated he measured 1.4 mR/hr at the surface of the gauge. The radionuclide was identified as cesium-137. The RSO stated he transported the gauge to their facility to store it in their vault. The gauge label plate states the gauge contains an 8 millicurie cesium - 137 source and a 40 millicurie americium - 241 source. The gauge cesium operating rod was fully retracted, and a lock was in place on the cesium source operating rod. The operating rod and lock were very corroded. The storage case the gauge was contained in looked to be in very good condition. The RSO provided pictures of the gauge to the Department. The RSO also provided the serial number for the gauge. The Department searched both its local and the national Nuclear Materials Event Database and did not find a record of the gauge being reported as lost in the State of Texas. The Department contacted the RSO for the gauge manufacturer and was provided with the name of the licensee the gauge had been sold to. A search of the Department's licensing records found the license of the company who had purchased the gauge had been revoked by the Department on July 1, 1991. The Department has arranged to take possession of the gauge on Monday March 31, 2025. Additional information will be provided as it is received in accordance with SA-300."

Texas incident number: 10187
NMED number: TX250021


Power Reactor
Event Number: 57733
Facility: Browns Ferry
Region: 2     State: AL
Unit: [2] [] []
RX Type: [1] GE-4,[2] GE-4,[3] GE-4
NRC Notified By: Sarah Torgersen
HQ OPS Officer: Kerby Scales
Notification Date: 05/27/2025
Notification Time: 11:17 [ET]
Event Date: 03/28/2025
Event Time: 16:04 [CDT]
Last Update Date: 05/27/2025
Emergency Class: Non Emergency
10 CFR Section:
50.73(a)(1) - Invalid Specif System Actuation
Person (Organization):
Desai, Binoy (R2DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N N 0 Refueling 100 Power Operation
Event Text
INVALID CONTAINMENT ISOLATION

The following information was provided by the licensee via phone and email:

"This 60-day telephone notification is being made per the reporting requirements specified by 10 CFR 50.73(a)(2)(iv)(A) and 10 CFR 50.73(a)(1) to describe an invalid actuation of a general containment isolation signal affecting more than one system [for Browns Ferry Unit 2].

"On March 28, 2025, operations personnel were performing post-maintenance testing of 2-HS-64-33 [hand switch], which operates 2-FSV-64-33, the suppression chamber exhaust outboard isolation valve. When the hand switch was taken to 'open' multiple annunciators were received, including 9-5B window 34, 'Fuse Failure'. Light indications above the hand switch were not lit. This condition resulted in a 'B'-side partial group 6 isolation. All systems responded as expected.

"Plant conditions which initiate primary containment isolation system (PCIS) group 6 actuations are reactor vessel low water level (level 3), high drywell pressure, or reactor building ventilation exhaust high radiation (reactor zone or refuel zone).

"At the time of the event, these conditions did not exist; therefore, the actuation of the PCIS was invalid and there were no safety consequences or impact to the health and safety of the public as a result of this event.

"Upon investigation a fuse was found to be cleared, which was the cause of the isolation. The fuse was replaced, the condition was cleared, and all systems were realigned as necessary.

"This event was entered into the corrective action program as condition report 2002404.

"The NRC Resident Inspector has been notified of this event."

The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:
Units 1 and 3 were not affected.


Non-Agreement State
Event Number: 57660
Rep Org: Dupont Specialty Products USA LLC
Licensee: Dupont Specialty Products USA LLC
Region: 1
City: Wilmington   State: DE
County:
License #: 07-13441-02
Agreement: N
Docket:
NRC Notified By: John Brisbin
HQ OPS Officer: Josue Ramirez
Notification Date: 04/10/2025
Notification Time: 12:41 [ET]
Event Date: 03/27/2025
Event Time: 00:00 [EDT]
Last Update Date: 04/10/2025
Emergency Class: Non Emergency
10 CFR Section:
20.2201(a)(1)(i) - Lost/Stolen LNM>1000x
Person (Organization):
Schussler, Jason (R1DO)
Vossmar, Patricia (R4DO)
NMSS_Events_Notification, (EMAIL)
ILTAB, (EMAIL)
CNSNS (Mexico), - (EMAIL) (EMAIL)
Event Text
THEFT OR LOSS OF LICENSED MATERIAL

The following is a summary of the information provided by the licensee via phone:

During a shipment from Wilmington, Delaware to Albuquerque, New Mexico, a 0.63 millicurie iron-55 (Fe-55) source was lost or stolen in transit. The last known location was Wilmington, Delaware. The source was shipped on March 27, 2025, and was identified as lost on April 10, 2025. The shipping package was delivered to the intended recipient, but the shipping package was compromised with the source missing. The shipper and the common carrier are investigating.

Model Number: FE5VZ29120005M
Serial Number: NK772

THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Agreement State
Event Number: 57823
Rep Org: Georgia Radioactive Material Pgm
Licensee: Aliance Health Care Services
Region: 1
City: Lilburn   State: GA
County: Gwinnett
License #: GA 1490-1
Agreement: Y
Docket:
NRC Notified By: Shatavia Walker
HQ OPS Officer: Brian P. Smith
Notification Date: 07/23/2025
Notification Time: 11:39 [ET]
Event Date: 03/27/2025
Event Time: 00:00 [EDT]
Last Update Date: 07/23/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Dentel, Glenn (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - RECOVERED SOURCES

The following report was received by the Georgia Radioactive Materials Program via email:

"On March 27, 2025, two sources (Ge-68) were found at a car repossession lot. It was determined the sources had been at that car repossession lot since sometime in October of 2024 and remained there until March 27, 2025, at which time GFD Hazmat recovered them and handed them off to EPD. The original activity was 1.49 mCi per source. The estimated decayed value was 0.05 mCi at the time of discovery and 0.04 mCi to date. The manufacturer confirmed the shipping location (GA 1490-1) and date of the source with a serial number.

"The licensee responded with disposal records to Sanders Medical (Tennessee licensed facility). Sanders was able to confirm receipt of the material on April 15, 2025. It was determined the serial numbers listed on the lead pigs did not match the serial number of the enclosed sources.

"On April 15, 2025, GA 2047-1 (Training Facility) gained possession of the found sources. The manufacturer (EZ) confirmed the same shipment location and licensee with the accurate serial numbers. After several attempts to reach out to Sanders, for confirmation of receipt, the State of Georgia could not get a response until July 15, 2025. At that time, a staff member from Sanders confirmed they did not receive, nor have they ever received the two sources.

"The licensee was unable to provide disposal records for the sources, although routinely uses Sanders for disposal services. The licensee received a notice of violation on July 23, 2025."

Georgia Incident Number: 102

THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Agreement State
Event Number: 57835
Rep Org: California Radiation Control Prgm
Licensee: Central Diagnostic Imaging Network
Region: 4
City: Glendale   State: CA
County:
License #: 6538
Agreement: Y
Docket:
NRC Notified By: Robert Greger
HQ OPS Officer: Ian Howard
Notification Date: 07/29/2025
Notification Time: 12:48 [ET]
Event Date: 03/27/2025
Event Time: 00:00 [PDT]
Last Update Date: 07/29/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL)
CNSNS (Mexico), - (EMAIL)
Event Text
AGREEMENT STATE REPORT - LOST SOURCES

The following information was provided by the California Radiation Control Program via email:

"The licensee's contract physicist reported that two Cs-137 attenuation correction sources with approximate activities of 13 mCi each were missing when the licensee went to conduct an inventory in March 2025. The licensee has searched their facility but could not locate the sources."

California Report ID Number: 072825

THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf