The U.S. Nuclear Regulatory Commission is in the process of rescinding or revising guidance and policies posted on this webpage in accordance with Executive Order 14151 Ending Radical and Wasteful Government DEI Programs and Preferencing, and Executive Order 14168 Defending Women From Gender Ideology Extremism and Restoring Biological Truth to the Federal Government. In the interim, any previously issued diversity, equity, inclusion, or gender-related guidance on this webpage should be considered rescinded that is inconsistent with these Executive Orders.

Event Notification Report for February 12, 2025

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
02/11/2025 - 02/12/2025

EVENT NUMBERS
57532 57533 57534 57540
Agreement State
Event Number: 57532
Rep Org: Arizona Dept of Health Services
Licensee: Strytek Engineering
Region: 4
City: Lake Havasu   State: AZ
County:
License #: 08-049
Agreement: Y
Docket:
NRC Notified By: Brian Goretzki
HQ OPS Officer: Adam Koziol
Notification Date: 02/04/2025
Notification Time: 12:23 [ET]
Event Date: 02/03/2025
Event Time: 14:00 [MST]
Last Update Date: 02/04/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Vossmar, Patricia (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - LOST AND RECOVERED GAUGE

The following information was provided by the Arizona Department of Health Services (The Department) via email:

"The Department received notification that an Instrotek 3500 Xplorer nuclear moisture/density gauge fell off the back of a truck in front of Lake Havasu High School. The technician returned to retrieve the gauge approximately 30-45 minutes later. The gauge contains 10 millicuries of Cs-137 and 40 millicuries of Am-241. The Department has requested additional information and continues to investigate the event.

"Additional information will be provided as it is received in accordance with SA-300."

Arizona Incident Number: 25-003


Agreement State
Event Number: 57533
Rep Org: Arizona Dept of Health Services
Licensee: Sonoran Heart, PLC
Region: 4
City: Avondale   State: AZ
County:
License #: 07-603
Agreement: Y
Docket:
NRC Notified By: Brian Goretzki
HQ OPS Officer: Ian Howard
Notification Date: 02/04/2025
Notification Time: 11:02 [ET]
Event Date: 12/31/2024
Event Time: 00:00 [MST]
Last Update Date: 02/05/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Vossmar, Patricia (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - UNQUALIFIED PERSONNEL

The following information was provided by the Arizona Department of Health Services (the Department) via phone and email:

"Seven (7) patients were injected with Tc-99m by a non-certified nuclear medicine technologist who knew he was not qualified to be injecting patients. The Department has requested additional information and continues to investigate the event."

Arizona Incident Number: 25-002


Agreement State
Event Number: 57534
Rep Org: Florida Bureau of Radiation Control
Licensee: Universal Engineering Sciences
Region: 1
City: Medley   State: FL
County:
License #: 4896-9
Agreement: Y
Docket:
NRC Notified By: Monroe Cooper
HQ OPS Officer: Ian Howard
Notification Date: 02/04/2025
Notification Time: 14:20 [ET]
Event Date: 02/04/2025
Event Time: 12:30 [EST]
Last Update Date: 02/04/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Young, Matt (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - DAMAGED TROXLER GAUGE

The following is a summary of information provided by the State of Florida, Bureau of Radiation Control (the BRC) via email:

On 2/4/2025, at 1334 EST, the BRC received notification of a damaged Troxler gauge. At around 1230, an employee accidently backed over the gauge. The gauge was not in use at the time of the incident. The backup radiation safety officer states the sources are contained and secured, only the housing was damaged. Prior to notifying the BRC, the licensee returned the gauge to its storage location.

Moisture Density Gauge Information
Manufacturer: Troxler
Model Number: 3430
Serial Number: 37867
Cs-137 Activity: 8 mCi
Am-241 Activity: 40 mCi

Florida Incident Number: FL25-012


Power Reactor
Event Number: 57540
Facility: Summer
Region: 2     State: SC
Unit: [1] [] []
RX Type: [1] W-3-LP,[2] W-AP1000,[3] W-AP1000
NRC Notified By: Elvis Zimmerman
HQ OPS Officer: Brian P. Smith
Notification Date: 02/10/2025
Notification Time: 15:21 [ET]
Event Date: 02/10/2025
Event Time: 12:16 [EST]
Last Update Date: 02/10/2025
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical
50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
Person (Organization):
Suggs, LaDonna (R2DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 M/R Y 67 Power Operation 0 Hot Standby
Event Text
MANUAL REACTOR TRIP DUE TO ELECTROHYDRAULIC CONTROL SYSTEM LEAK
?
The following information was provided by the licensee via phone and email:

"At 1216 EST, on 2/10/2025 with Unit 1 in mode 1 at 66.5 percent power, the reactor was manually tripped due to an electro-hydraulic control power system leak. The trip was not complex with all systems responding normally post-trip.

"Operations responded and stabilized the plant. Decay heat is being removed by the emergency feedwater system.

"Due to the reactor protection system actuation while critical, this event is being reported as a four-hour, non-emergency notification per 10 CFR50.72(b)(2)(iv)(B) and an eight-hour, non-emergency notification per 10CFR 50.72(b)(3)(iv)(A) resulting from a valid actuation of the reactor protection and emergency feedwater systems.

"There was no impact on the health and safety of the public or plant personnel.

"The NRC Resident Inspector has been notified."