Skip to main content

Event Notification Report for January 26, 2025

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
01/25/2025 - 01/26/2025

EVENT NUMBERS
575165752057515
Power Reactor
Event Number: 57516
Facility: River Bend
Region: 4     State: LA
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: Darren Farthing
HQ OPS Officer: Tenisha Meadows
Notification Date: 01/27/2025
Notification Time: 14:15 [ET]
Event Date: 01/27/2025
Event Time: 12:05 [CST]
Last Update Date: 01/27/2025
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(xi) - Offsite Notification
Person (Organization):
Gaddy, Vincent (R4DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
OFFSITE NOTIFICATION DUE TO WASTEWATER DISCHARGE

The following information was provided by the licensee via phone and email:

"On January 27, 2025, at 1205 CST, River Bend Station performed a notification to the Louisiana Department of Environmental Quality per the Louisiana Pollutant Discharge Elimination System (LPDES) Permit (# LA0042731) due to a wastewater leak. The wastewater leak originated at a sewage lift pump station and resulted in an unauthorized discharge. This notification is being made as a four-hour, non-emergency report for notification to other government agency in accordance with 10 CFR 50.72(b)(2)(xi). There was no impact to the health and safety of the public or plant personnel.

"The NRC Resident Inspector has been notified."


Agreement State
Event Number: 57520
Rep Org: Ohio Bureau of Radiation Protection
Licensee: University Hospitals of Cleveland
Region: 3
City: Cleveland   State: OH
County:
License #: 02110180077
Agreement: Y
Docket:
NRC Notified By: Michael J. Rubadue
HQ OPS Officer: Ernest West
Notification Date: 01/29/2025
Notification Time: 12:51 [ET]
Event Date: 01/27/2025
Event Time: 00:00 [EST]
Last Update Date: 01/30/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Ziolkowski, Michael (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Allen, Logan (NMSS)
Event Text
AGREEMENT STATE REPORT - MEDICAL EVENT

The following information was provided by the Ohio Department of Health via email:

"On January 28, 2025, the Ohio Department of Health, Bureau of Environmental Health and Radiation Protection was notified by University Hospitals of Cleveland that during a therapeutic infusion of Pluvicto (Lu-177) [that was administered on January 27, 2025], 60.9 mCi of a total dose of 295 mCi was extravasated in the patient's right arm antecubital area [i.e. not the intended treatment site]. The licensee calculated a 0.61 Gy dose to the skin near the extravasation site based on imaging taken from 20 minutes to 22 hours post-infusion. At 22 hours post infusion, 0.46 mCi remained around the injection site based on imaging. The authorized user believes the material has drained through the lymphatic system to the prostate."

Ohio Item Number: OH250001

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.




Power Reactor
Event Number: 57515
Facility: Quad Cities
Region: 3     State: IL
Unit: [1] [2] []
RX Type: [1] GE-3,[2] GE-3
NRC Notified By: Christopher Thompson
HQ OPS Officer: Josue Ramirez
Notification Date: 01/26/2025
Notification Time: 20:35 [ET]
Event Date: 01/26/2025
Event Time: 14:50 [CST]
Last Update Date: 01/26/2025
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(v)(D) - Accident Mitigation
Person (Organization):
Betancourt-Roldan, Diana (R3DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 90 Power Operation 90 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
CONTROL ROOM EMERGENCY VENTILATION AIR CONDITIONING SYSTEM INOPERABLE

The following information was provided by the licensee via phone and email:

"On January 26, 2025, at 1450 CST, it was discovered that the Control Room Emergency Ventilation Air Conditioning (CREVAC) system was inoperable. Due to this inoperability, the system was in a condition that could have prevented the fulfillment of a safety function, and therefore, this condition is being reported as an eight-hour non-emergency notification per 10 CFR 50.72(b)(3)(v)(D). The CREVAC system is a single train system.

"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."