Event Notification Report for June 17, 2024
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
06/16/2024 - 06/17/2024
Agreement State
Event Number: 57073
Rep Org: SC Dept of Health & Env Control
Licensee: Medical University of South Carolina
Region: 1
City: Charleston State: SC
County:
License #: 081
Agreement: Y
Docket:
NRC Notified By: Korina Koci
HQ OPS Officer: Ernest West
Licensee: Medical University of South Carolina
Region: 1
City: Charleston State: SC
County:
License #: 081
Agreement: Y
Docket:
NRC Notified By: Korina Koci
HQ OPS Officer: Ernest West
Notification Date: 04/12/2024
Notification Time: 13:53 [ET]
Event Date: 04/12/2024
Event Time: 11:30 [EDT]
Last Update Date: 06/14/2024
Notification Time: 13:53 [ET]
Event Date: 04/12/2024
Event Time: 11:30 [EDT]
Last Update Date: 06/14/2024
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Defrancisco, Anne (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Defrancisco, Anne (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
EN Revision Imported Date: 6/17/2024
EN Revision Text: AGREEMENT STATE - MEDICAL UNDERDOSE
The following information was provided by the South Carolina Department of Health and Environmental Control (Department) via email:
"The South Carolina Department of Health and Environmental Control was notified via telephone at approximately 1301 [EDT] on 4/12/24, that a medical event had been discovered by the licensee on 4/12/24 at approximately 1130 [EDT]. The Medical University of South Carolina (MUSC) reports an underdose to a patient's liver during a Y-90 microsphere procedure by 78 percent of the prescribed 120 Gray (Gy) dose. The licensee estimates that the patient received 27 Gy, which is 22 percent of the intended 120 Gy dose. The licensee reports that the total dose or activity delivered differs from the prescribed dose or activity, as documented in the written directive, by 20 percent or more. The patient was notified of this medical event verbally.
"The licensee reports no immediate or ongoing concerns to public health and safety. Department inspectors will be dispatched to the facility to investigate this event. This event is still under investigation by the South Carolina Department of Health and Environmental Control."
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
* * * UPDATE ON 04/26/2024 AT 0934 EDT FROM ADAM GAUSE TO JOSUE RAMIREZ * * *
The following update was provided by the South Carolina Department of Health and Environmental Control via email:
"The licensee has submitted a 15-day written report. This event is still under investigation by the South Carolina Department of Health and Environmental Control.
"The internal identification number for this event is SC240001."
Notified R1DO (Werkheiser), NMSS_EVENTS_NOTIFICATION via email.
* * * UPDATE ON 06/14/2024 AT 1211 EDT FROM KORINA KOCI TO ROBERT THOMPSON * * *
The following information was provided by the licensee via email:
"Department Inspectors performed an on-site investigation on 05/23/24. Details of the event were consistent with the licensee's notification and written report. The licensee attributes the root cause of the failure to administer the full dosage to the administration lines due to administration line blockage, specifically a faulty needle in the plunger of the administration kit. This event is considered closed."
Notified R1DO (Eve), NMSS_EVENTS_NOTIFICATION via email.
EN Revision Text: AGREEMENT STATE - MEDICAL UNDERDOSE
The following information was provided by the South Carolina Department of Health and Environmental Control (Department) via email:
"The South Carolina Department of Health and Environmental Control was notified via telephone at approximately 1301 [EDT] on 4/12/24, that a medical event had been discovered by the licensee on 4/12/24 at approximately 1130 [EDT]. The Medical University of South Carolina (MUSC) reports an underdose to a patient's liver during a Y-90 microsphere procedure by 78 percent of the prescribed 120 Gray (Gy) dose. The licensee estimates that the patient received 27 Gy, which is 22 percent of the intended 120 Gy dose. The licensee reports that the total dose or activity delivered differs from the prescribed dose or activity, as documented in the written directive, by 20 percent or more. The patient was notified of this medical event verbally.
"The licensee reports no immediate or ongoing concerns to public health and safety. Department inspectors will be dispatched to the facility to investigate this event. This event is still under investigation by the South Carolina Department of Health and Environmental Control."
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
* * * UPDATE ON 04/26/2024 AT 0934 EDT FROM ADAM GAUSE TO JOSUE RAMIREZ * * *
The following update was provided by the South Carolina Department of Health and Environmental Control via email:
"The licensee has submitted a 15-day written report. This event is still under investigation by the South Carolina Department of Health and Environmental Control.
"The internal identification number for this event is SC240001."
Notified R1DO (Werkheiser), NMSS_EVENTS_NOTIFICATION via email.
* * * UPDATE ON 06/14/2024 AT 1211 EDT FROM KORINA KOCI TO ROBERT THOMPSON * * *
The following information was provided by the licensee via email:
"Department Inspectors performed an on-site investigation on 05/23/24. Details of the event were consistent with the licensee's notification and written report. The licensee attributes the root cause of the failure to administer the full dosage to the administration lines due to administration line blockage, specifically a faulty needle in the plunger of the administration kit. This event is considered closed."
Notified R1DO (Eve), NMSS_EVENTS_NOTIFICATION via email.
Non-Agreement State
Event Number: 57168
Rep Org: Snyder and Associates, Inc
Licensee: Snyder and Associates, Inc
Region: 3
City: Maryville State: MO
County:
License #: 24-32019-01
Agreement: N
Docket:
NRC Notified By: Larry Bradshaw
HQ OPS Officer: Ian Howard
Licensee: Snyder and Associates, Inc
Region: 3
City: Maryville State: MO
County:
License #: 24-32019-01
Agreement: N
Docket:
NRC Notified By: Larry Bradshaw
HQ OPS Officer: Ian Howard
Notification Date: 06/10/2024
Notification Time: 08:31 [ET]
Event Date: 06/10/2024
Event Time: 04:15 [CDT]
Last Update Date: 06/10/2024
Notification Time: 08:31 [ET]
Event Date: 06/10/2024
Event Time: 04:15 [CDT]
Last Update Date: 06/10/2024
Emergency Class: Non Emergency
10 CFR Section:
20.2201(a)(1)(i) - Lost/Stolen LNM>1000x
10 CFR Section:
20.2201(a)(1)(i) - Lost/Stolen LNM>1000x
Person (Organization):
Hartman, Tom (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
Hartman, Tom (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
LOST RADIOACTIVE SOURCE
The following is a summary of information obtained from the licensee in accordance with Headquarters Operations Officers report guidance:
At 0415 CDT, on 6/10/2024, the Radiation Safety Officer's (RSO) truck, which contained a Troxler 3440 nuclear gauge (serial number 66812), was stolen (loss of control). The RSO left the truck running with the keys in the ignition and the nuclear gauge secured inside when an individual decided to get in the drivers seat and drive away. When the RSO realized the truck was stolen, they immediately contacted Missouri local law enforcement. The nuclear gauge contains 44 mCi of Am241:Be.
* * * UPDATE ON 6/10/2024 AT 1032 EDT FROM LARRY BRADSHAW TO IAN HOWARD * * *
The following is a summary of information obtained from the licensee in accordance with Headquarters Operations Officers report guidance:
At 0902 CDT, on 6/10/2024, the truck was located and returned to the RSO with the Troxler gauge secure in its locked case. There was no indication of tampering with the case or the locks used to secure the Troxler gauge.
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following is a summary of information obtained from the licensee in accordance with Headquarters Operations Officers report guidance:
At 0415 CDT, on 6/10/2024, the Radiation Safety Officer's (RSO) truck, which contained a Troxler 3440 nuclear gauge (serial number 66812), was stolen (loss of control). The RSO left the truck running with the keys in the ignition and the nuclear gauge secured inside when an individual decided to get in the drivers seat and drive away. When the RSO realized the truck was stolen, they immediately contacted Missouri local law enforcement. The nuclear gauge contains 44 mCi of Am241:Be.
* * * UPDATE ON 6/10/2024 AT 1032 EDT FROM LARRY BRADSHAW TO IAN HOWARD * * *
The following is a summary of information obtained from the licensee in accordance with Headquarters Operations Officers report guidance:
At 0902 CDT, on 6/10/2024, the truck was located and returned to the RSO with the Troxler gauge secure in its locked case. There was no indication of tampering with the case or the locks used to secure the Troxler gauge.
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Power Reactor
Event Number: 57172
Facility: FitzPatrick
Region: 1 State: NY
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: Ryan Perry
HQ OPS Officer: Bill Nytko
Region: 1 State: NY
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: Ryan Perry
HQ OPS Officer: Bill Nytko
Notification Date: 06/13/2024
Notification Time: 17:12 [ET]
Event Date: 06/13/2024
Event Time: 13:31 [EDT]
Last Update Date: 06/13/2024
Notification Time: 17:12 [ET]
Event Date: 06/13/2024
Event Time: 13:31 [EDT]
Last Update Date: 06/13/2024
Emergency Class: Non Emergency
10 CFR Section:
26.719 - Fitness For Duty
10 CFR Section:
26.719 - Fitness For Duty
Person (Organization):
Eve, Elise (R1DO)
FFD Group, (EMAIL)
Eve, Elise (R1DO)
FFD Group, (EMAIL)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
The following information was provided by the licensee via email:
"At 1331 EDT on 6/13/2024, it was determined that a non-active licensed operator supervisor tested positive in accordance with the fitness for duty testing program. The individual's authorization for site access has been denied. The NRC Resident Inspector has been notified."
"At 1331 EDT on 6/13/2024, it was determined that a non-active licensed operator supervisor tested positive in accordance with the fitness for duty testing program. The individual's authorization for site access has been denied. The NRC Resident Inspector has been notified."
Non-Power Reactor
Event Number: 57174
Rep Org: Texas A&M University (TAMN)
Licensee: Texas A&M University
Region: 0
City: College Station State: TX
County: Brazos
License #: R-83
Agreement: Y
Docket: 05000128
NRC Notified By: Jere Jenkins
HQ OPS Officer: Josue Ramirez
Licensee: Texas A&M University
Region: 0
City: College Station State: TX
County: Brazos
License #: R-83
Agreement: Y
Docket: 05000128
NRC Notified By: Jere Jenkins
HQ OPS Officer: Josue Ramirez
Notification Date: 06/14/2024
Notification Time: 15:35 [ET]
Event Date: 06/14/2024
Event Time: 11:00 [CDT]
Last Update Date: 06/14/2024
Notification Time: 15:35 [ET]
Event Date: 06/14/2024
Event Time: 11:00 [CDT]
Last Update Date: 06/14/2024
Emergency Class: Non Emergency
10 CFR Section:
10 CFR Section:
Person (Organization):
Patrick Boyle (NRR PM)
Andrew Waugh (NPR EVEN)
Patrick Boyle (NRR PM)
Andrew Waugh (NPR EVEN)
TECHNICAL SPECIFICATION REPORTABLE OCCURRENCE
The following information was provided by the licensee via email:
"At approximately 1100 CDT on June 14, 2024, during routine fuel inspections required under Technical Specification 4.1.5, a fuel pin (serial number 11420) did not pass the go/no-go test for transverse bend. This measurement is described in Technical Specification 3.1.5.2.a as part of the fuel inspection conducted under the surveillance described in Technical Specification 4.1.5. Failure of an element to meet any one of the specifications listed in Technical Specification 3.1.5.2 specifies that the fuel element is considered 'damaged' and therefore may not be used in reactor operations.
"Visual inspection of the pin prior to placement in the test rig did not indicate any obvious degradation that would be exceptional for a pin with seventeen years of burnup history.
"There have been no indications of cladding failure on routine primary coolant analyses.
"The pin has been removed from service and will be replaced with a spare unused element.
"As required by Technical Specification 4.1.5.2, an inspection of the entire core fuel inventory will be initiated and will be completed prior to resuming routine operations.
"After the identification of the failure, the test rig calibration was confirmed and the pin was checked again, confirming the element failed the transverse bend specification.
"The reactor was not operating at the time of the event."
NRC Project Manager has been notified.
The following information was provided by the licensee via email:
"At approximately 1100 CDT on June 14, 2024, during routine fuel inspections required under Technical Specification 4.1.5, a fuel pin (serial number 11420) did not pass the go/no-go test for transverse bend. This measurement is described in Technical Specification 3.1.5.2.a as part of the fuel inspection conducted under the surveillance described in Technical Specification 4.1.5. Failure of an element to meet any one of the specifications listed in Technical Specification 3.1.5.2 specifies that the fuel element is considered 'damaged' and therefore may not be used in reactor operations.
"Visual inspection of the pin prior to placement in the test rig did not indicate any obvious degradation that would be exceptional for a pin with seventeen years of burnup history.
"There have been no indications of cladding failure on routine primary coolant analyses.
"The pin has been removed from service and will be replaced with a spare unused element.
"As required by Technical Specification 4.1.5.2, an inspection of the entire core fuel inventory will be initiated and will be completed prior to resuming routine operations.
"After the identification of the failure, the test rig calibration was confirmed and the pin was checked again, confirming the element failed the transverse bend specification.
"The reactor was not operating at the time of the event."
NRC Project Manager has been notified.
Power Reactor
Event Number: 57175
Facility: Waterford
Region: 4 State: LA
Unit: [3] [] []
RX Type: [3] CE
NRC Notified By: Kylie Granier
HQ OPS Officer: Kerby Scales
Region: 4 State: LA
Unit: [3] [] []
RX Type: [3] CE
NRC Notified By: Kylie Granier
HQ OPS Officer: Kerby Scales
Notification Date: 06/16/2024
Notification Time: 16:41 [ET]
Event Date: 06/16/2024
Event Time: 12:33 [CDT]
Last Update Date: 06/16/2024
Notification Time: 16:41 [ET]
Event Date: 06/16/2024
Event Time: 12:33 [CDT]
Last Update Date: 06/16/2024
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical 50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical 50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
Person (Organization):
Taylor, Nick (R4DO)
Taylor, Nick (R4DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 3 | A/R | Y | 93 | Power Operation | 0 | Hot Standby |
AUTOMATIC REACTOR TRIP
The following information was provided by the licensee via email:
"On June 16, 2024, at 1233 CDT, Waterford Steam Electric Station Unit 3 was operating at 93 percent power when an automatic reactor trip occurred. Immediately following the reactor trip, emergency feedwater (EFW) actuated automatically. The unit is currently in Mode 3. All control rods fully inserted. Decay heat removal is via the main condenser. Preliminary evaluation indicates that all plant systems functioned normally after the reactor trip, except steam generator (SG) feedwater pump 'A' tripped and SG '1' main feed regulatory controller went to manual. Steam generator water levels are being controlled with the SG feedwater pump 'B'. The cause of the trip is currently being investigated.
"This event is being reported as a 4-hour non-emergency notification in accordance with 10 CFR 50.72(b)(2)(iv)(B) as an actuation of the reactor protection system when the reactor is critical and as an 8-hour non-emergency notification in accordance with 10 CFR 50.72(b)(3)(iv)(A) as a valid actuation of the EFW system.
"The NRC Resident Inspector has been notified."
The following information was provided by the licensee via email:
"On June 16, 2024, at 1233 CDT, Waterford Steam Electric Station Unit 3 was operating at 93 percent power when an automatic reactor trip occurred. Immediately following the reactor trip, emergency feedwater (EFW) actuated automatically. The unit is currently in Mode 3. All control rods fully inserted. Decay heat removal is via the main condenser. Preliminary evaluation indicates that all plant systems functioned normally after the reactor trip, except steam generator (SG) feedwater pump 'A' tripped and SG '1' main feed regulatory controller went to manual. Steam generator water levels are being controlled with the SG feedwater pump 'B'. The cause of the trip is currently being investigated.
"This event is being reported as a 4-hour non-emergency notification in accordance with 10 CFR 50.72(b)(2)(iv)(B) as an actuation of the reactor protection system when the reactor is critical and as an 8-hour non-emergency notification in accordance with 10 CFR 50.72(b)(3)(iv)(A) as a valid actuation of the EFW system.
"The NRC Resident Inspector has been notified."
Agreement State
Event Number: 57169
Rep Org: Texas Dept of State Health Services
Licensee: RONE ENGINEERING SERVICES LTD
Region: 4
City: DALLAS State: TX
County:
License #: L 02356
Agreement: Y
Docket:
NRC Notified By: Art Tucker
HQ OPS Officer: Bill Nytko
Licensee: RONE ENGINEERING SERVICES LTD
Region: 4
City: DALLAS State: TX
County:
License #: L 02356
Agreement: Y
Docket:
NRC Notified By: Art Tucker
HQ OPS Officer: Bill Nytko
Notification Date: 06/11/2024
Notification Time: 17:05 [ET]
Event Date: 06/10/2024
Event Time: 00:00 [CDT]
Last Update Date: 06/11/2024
Notification Time: 17:05 [ET]
Event Date: 06/10/2024
Event Time: 00:00 [CDT]
Last Update Date: 06/11/2024
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Taylor, Nick (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
CNSNS (Mexico), - (EMAIL)
Taylor, Nick (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
CNSNS (Mexico), - (EMAIL)
AGREEMENT STATE REPORT - LOST SOURCE
The following was received from the Texas Department of State Health Services (the Department) via email:
"On June 11, 2024, the Department was notified by the licensee's radiation safety officer (RSO) that a 40 millicurie americium-241/beryllium (Am-241/Be) source from a Troxler 3430 moisture/density gauge could not be located. The gauge did not pass the standardization test, and was later sent to the service provider. On June 10, 2024, the service provider informed the RSO that the gauge was inspected, the cap that held the Am-241/Be source in place was no longer screwed in, and the source was missing. Radiation surveys were conducted at the facility but were unable to locate the Am-241/Be source. RSO contacted the service provider and requested a facility survey. The RSO will be interviewing their technicians and reviewing use records for the gauge in an attempt to locate where the source could have fallen out of the gauge. An exposure risk to an individual was not reported. Additional information will be provided as it is received in accordance with SA-300."
TX Incident Number: 10109
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following was received from the Texas Department of State Health Services (the Department) via email:
"On June 11, 2024, the Department was notified by the licensee's radiation safety officer (RSO) that a 40 millicurie americium-241/beryllium (Am-241/Be) source from a Troxler 3430 moisture/density gauge could not be located. The gauge did not pass the standardization test, and was later sent to the service provider. On June 10, 2024, the service provider informed the RSO that the gauge was inspected, the cap that held the Am-241/Be source in place was no longer screwed in, and the source was missing. Radiation surveys were conducted at the facility but were unable to locate the Am-241/Be source. RSO contacted the service provider and requested a facility survey. The RSO will be interviewing their technicians and reviewing use records for the gauge in an attempt to locate where the source could have fallen out of the gauge. An exposure risk to an individual was not reported. Additional information will be provided as it is received in accordance with SA-300."
TX Incident Number: 10109
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 57170
Rep Org: California Radiation Control Prgm
Licensee: Mistras Group, Inc.
Region: 4
City: Martinez State: CA
County:
License #: 4886-48
Agreement: Y
Docket:
NRC Notified By: Nawab Kahn
HQ OPS Officer: Natalie Starfish
Licensee: Mistras Group, Inc.
Region: 4
City: Martinez State: CA
County:
License #: 4886-48
Agreement: Y
Docket:
NRC Notified By: Nawab Kahn
HQ OPS Officer: Natalie Starfish
Notification Date: 06/11/2024
Notification Time: 17:52 [ET]
Event Date: 06/04/2024
Event Time: 10:34 [PDT]
Last Update Date: 06/11/2024
Notification Time: 17:52 [ET]
Event Date: 06/04/2024
Event Time: 10:34 [PDT]
Last Update Date: 06/11/2024
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Taylor, Nick (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Taylor, Nick (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - STUCK SOURCE
The following information was provided by the California Department of Public Health (the Department) via email:
"At 1034 PDT on June 6, 2024, the Department received an email from the Mistras Group, notifying the Department of an event at the MRC Martinez Refinery. At 1407 PDT on June 3, 2024, the radiation safety officer (RSO) received a call from a radiography crew at MRC Martinez Refinery regarding a 61 curie Ir-192 source (serial number 475 I) that would not retract back into the industrial nuclear IR-100 radiographic exposure device (serial number 4059). The RSO arrived on the site at 1444 PDT to find that the extension tube female end crimp had dislodged from the tubing and was laying on the deck of the structure that the crew was working on. At 1555 PDT, the RSO was able to manipulate the cable into a position where they were able to retract the source back into the locked and shielded position without incident or overexposure. Five crew members were present during the time the source was in an unshielded position: the RSO, one radiographer trainer, and three assistants. The highest exposure recorded to their instadose [dosimeter] was 40 mR for the radiographer trainer. The RSO will submit a written report within 30 days following an investigation."
California 5010 report number: 060424
The following information was provided by the California Department of Public Health (the Department) via email:
"At 1034 PDT on June 6, 2024, the Department received an email from the Mistras Group, notifying the Department of an event at the MRC Martinez Refinery. At 1407 PDT on June 3, 2024, the radiation safety officer (RSO) received a call from a radiography crew at MRC Martinez Refinery regarding a 61 curie Ir-192 source (serial number 475 I) that would not retract back into the industrial nuclear IR-100 radiographic exposure device (serial number 4059). The RSO arrived on the site at 1444 PDT to find that the extension tube female end crimp had dislodged from the tubing and was laying on the deck of the structure that the crew was working on. At 1555 PDT, the RSO was able to manipulate the cable into a position where they were able to retract the source back into the locked and shielded position without incident or overexposure. Five crew members were present during the time the source was in an unshielded position: the RSO, one radiographer trainer, and three assistants. The highest exposure recorded to their instadose [dosimeter] was 40 mR for the radiographer trainer. The RSO will submit a written report within 30 days following an investigation."
California 5010 report number: 060424