Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for April 24, 2024

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
04/23/2024 - 04/24/2024

Agreement State
Event Number: 57078
Rep Org: California Radiation Control Prgm
Licensee: Testing Engineers, Inc.
Region: 4
City: Concord   State: CA
County:
License #: 3691-07
Agreement: Y
Docket:
NRC Notified By: K. Arunika Hewadikaram
HQ OPS Officer: Ernest West
Notification Date: 04/16/2024
Notification Time: 15:57 [ET]
Event Date: 04/13/2024
Event Time: 00:00 [PDT]
Last Update Date: 04/16/2024
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Young, Cale (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
CNSNS (Mexico), - (EMAIL)
Event Text
AGREEMENT STATE - STOLEN GAUGE

The following information was provided by the California Department of Public Health, Radiologic Health Branch (RHB) via email:

"On 4/15/2024, the California Office of Emergency Services (OES) forwarded a report from Testing Engineers, Inc. The radiation safety officer (RSO) notified OES that one of their nuclear gauges (CPN MC-1, serial number MD71108870 containing 10 mCi of Cs-137 and 50 mCi of Am-241) was stolen from a storage unit that is located within a public storage facility in Concord, CA. The gauge was stolen from the storage unit at an unknown time between 04/13/2024 and 04/14/2024, but was discovered missing at 1541 [PDT] on 04/15/2024. A car was used to ram the door of the storage unit, and a pry bar was used to remove the gauge from a locked cabinet. Local law enforcement was notified, and a reward was posted on Craigslist, Facebook, and Nextdoor for the safe return of the gauge.

"RHB will investigate the incident."


THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Agreement State
Event Number: 57080
Rep Org: Texas Dept of State Health Services
Licensee: The Dow Chemical Company
Region: 4
City: Lake Jackson   State: TX
County:
License #: L 00451
Agreement: Y
Docket:
NRC Notified By: Art Tucker
HQ OPS Officer: Bill Gott
Notification Date: 04/17/2024
Notification Time: 10:34 [ET]
Event Date: 04/16/2024
Event Time: 00:00 [CDT]
Last Update Date: 04/17/2024
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Young, Cale (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - DAMAGED GAUGE SHUTTER

The following was received from the Texas Department of State Health Services (the Department) via email:

"On April 16, 2024, the Department was notified by the licensee that they had removed a Natco model B-20-06 nuclear gauge containing a 175 millicurie (original activity) Cs-137 source from a vessel to allow work on the vessel. The gauge shutter was in the closed position and was functioning normally. Dose rates taken at the gauge before removal were normal at 0.65 millirem per hour.

"After the gauge was removed from the vessel, it was placed on a pallet with other gauges that had been removed from the vessel. At this time, the licensee performed additional radiation surveys, and the dose rate taken within a foot at the top of the gauge shutter was now reading 8.65 millirem per hour. The gauges were all moved to a locked storage location.

"The licensee has contacted a service company to inspect the gauge and determine the cause for the increased dose rates. The licensee's radiation safety officer (RSO) stated the shutter may have been damaged as the gauge was being moved to the pallet. The RSO stated no overexposures had occurred.

"Additional information will be provided as it is received in accordance with SA-300."

Texas Incident No.: 10099

Texas NMED No.: TX240012


Part 21
Event Number: 57088
Rep Org: Global Nuclear Fuel
Licensee: GE-Hitachi Nuclear Energy Americas, LLC
Region: 2
City: Wilmington   State: NC
County:
License #: SNM-1097
Agreement: Y
Docket:
NRC Notified By: Ralph Hayes
HQ OPS Officer: Adam Koziol
Notification Date: 04/22/2024
Notification Time: 14:33 [ET]
Event Date: 04/22/2024
Event Time: 00:00 [EDT]
Last Update Date: 04/26/2024
Emergency Class: Non Emergency
10 CFR Section:
21.21(d)(3)(i) - Defects And Noncompliance
Person (Organization):
Werkheiser, Dave (R1DO)
Part 21/50.55 Reactors, - (EMAIL)
Betancourt-Roldan, Diana (R3DO)
Warnick, Greg (R4DO)
Event Text
EN Revision Imported Date: 4/29/2024

EN Revision Text: PART 21 - FUEL ASSEMBLY SPACER RELOCATION

The following is a summary of information provided by the licensee via email:

Global Nuclear Fuel discovered instances of GNF3 fuel assembly spacers relocating within the fuel bundle. A safety communication was issued in 2022 following the discovery of a raised water rod (WR) at Grand Gulf Nuclear Station. Shutdown inspections in February 2024 at Lasalle identified five spacers out of position. Shutdown inspections at Limerick in April 2024 identified one spacer out of position. Those discoveries prompted this Part 21 report. An evaluation concluded that the relocated spacers could result in a degraded critical power margin, but the evaluation of this condition indicates it will not compromise or greatly reduce protection to public health and safety.

Plants with suspect bundles installed:
Grand Gulf Nuclear Station (Raised WR but no defective spacers)
Lasalle (1 bundle with 5 relocated spacers found)
Limerick (1 bundle with 4 relocated spacers found)
Nine Mile Point (No defects found)
Fermi (No defects found)
Peach Bottom (Shutdown scheduled in Fall 2024)
Fitzpatrick (Shutdown scheduled in Fall 2024)

* * * UPDATE ON 4/26/24 AT 1220 EDT FROM LISA SCHICHLEIN TO ADAM KOZIOL * * *

Updated to correct administrative errors in the summary of defects. Corrections were made above.

Notified R1DO (Werkheiser), R3DO (Betancourt-Roldan), R4DO (Warnick), Part 21/Reactor Group (email)


Agreement State
Event Number: 57081
Rep Org: PA Bureau of Radiation Protection
Licensee: University of Pennsylvania
Region: 1
City: Philadelphia   State: PA
County:
License #: PA-0131
Agreement: Y
Docket:
NRC Notified By: John Chippo
HQ OPS Officer: Adam Koziol
Notification Date: 04/18/2024
Notification Time: 16:32 [ET]
Event Date: 04/17/2024
Event Time: 00:00 [EDT]
Last Update Date: 04/18/2024
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Dimitriadis, Anthony (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - MEDICAL UNDERDOSE

The following information was provided by the Pennsylvania Department of Environmental Protection Bureau of Radiation Protection (the Department) email:

"On April 18, 2024, the licensee informed the Department of a medical event. It is reportable per 10 CFR 35.3045.

"On April 17, 2024, a patient was receiving an iodine-131 [sodium iodine solution] treatment. The patient was prescribed 100 mCi of I-131. However, the patient received only 5 mCi of I-131. At this time no other information is available. The Department will update this event as soon as more information is provided.

"The Department will perform a reactive inspection. More information will be provided upon receipt."

PA Event Number: PA240006

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.


Agreement State
Event Number: 57082
Rep Org: Texas Dept of State Health Services
Licensee: Valero Refining Company
Region: 4
City: Texas City   State: TX
County:
License #: L-02578
Agreement: Y
Docket:
NRC Notified By: Art Tucker
HQ OPS Officer: Adam Koziol
Notification Date: 04/18/2024
Notification Time: 18:18 [ET]
Event Date: 04/18/2024
Event Time: 00:00 [CDT]
Last Update Date: 04/18/2024
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Young, Cale (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - STUCK SHUTTER

The following was received from the Texas Department of State Health Services (the Department) via email:

"On April 18, 2024, the Department was notified by the licensee that the shutter on a Vega model SH-F1 nuclear gauge failed to close. The gauge contains a 20 millicurie (original activity) cesium - 137 source. Open is the normal position for the gauge shutter. The licensee reported there is no risk of additional radiation exposure to members of the general public or radiation workers, due to this failure. The manufacturer has been contacted to repair the gauge shutter. Additional information will be provided as it is received in accordance with SA-300."

Texas Incident Number: 10100

Texas NMED Number: TX240013