Event Notification Report for April 19, 2024

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
04/18/2024 - 04/19/2024

Non-Agreement State
Event Number: 57007
Rep Org: Kirtland Air Force Base
Licensee: Kirtland Air Force Base
Region: 4
City: Albuquerque   State: NM
County:
License #: 42-23539-01AF
Agreement: N
Docket:
NRC Notified By: Ryan Eiswerth
HQ OPS Officer: Adam Koziol
Notification Date: 03/05/2024
Notification Time: 14:17 [ET]
Event Date: 03/05/2024
Event Time: 10:00 [MST]
Last Update Date: 04/18/2024
Emergency Class: Non Emergency
10 CFR Section:
36.83(a)(1) - Unshield Stuck Source
Person (Organization):
NMSS_EVENTS_NOTIFICATION (EMAIL)
Gaddy, Vincent (R4DO)
O'Keefe, Neil (R4 PM)
Crouch, Howard (IR)
Event Text
EN Revision Imported Date: 4/19/2024

EN Revision Text: STUCK IRRADIATOR SOURCE

The following information was provided by the licensee via telephone and email:

At 1000 MST on 3/5/24, a 10,000 Ci Co-60 source (Model 7810) became stuck in the unshielded position during operator training. The irradiator is a J.L. Shepherd, Model SDF-34-M1, panoramic dry-source storage type. Upon determining that the source was stuck, the operator attempted to manipulate the source back into the shielded position using the emergency cable, but it came loose. Site staff have secured the irradiator facility.

No personnel exposure occurred, and there are no elevated dose rates outside of the irradiator enclosure. The site has requested manufacturer support to resolve the issue.

The NRC Project Manager (O'Keefe) has been notified.

* * * UPDATE ON 4/18/24 AT 1508 EST FROM MAJ RYAN EISWERTH TO ADAM KOZIOL * * *

On 3/18/24, authorized users were able to return the source to a shielded position. A post-event inspection was scheduled during the week starting 4/22/24 with the vendor to verify operability of the irradiator.

At approximately 1000 MST on 4/18/24, while an authorized user was conducting a performance functional check in preparation for the scheduled inspection, the irradiator source again became stuck in an unshielded position.

The irradiator had not been used since the initial report on 3/5/24. No personnel exposure occurred, and there are no elevated dose rates outside of the irradiator enclosure. The site has requested manufacturer support to resolve the issue.

Notified R4DO (Young), IRMOC (Crouch), and NMSS Events (email).


Fuel Cycle Facility
Event Number: 57061
Facility: Louisiana Energy Services
Region: 2     State: NM
Unit: [] [] []
RX Type:
NRC Notified By: David Hurd
HQ OPS Officer: Kerby Scales
Notification Date: 04/02/2024
Notification Time: 02:36 [ET]
Event Date: 04/01/2024
Event Time: 23:45 [MDT]
Last Update Date: 04/18/2024
Emergency Class: Non Emergency
10 CFR Section:
PART 70 APP A (a)(4) - All Safety Items Unavailable
Person (Organization):
Miller, Mark (R2DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
EN Revision Imported Date: 4/19/2024

EN Revision Text: ITEM RELIED ON FOR SAFETY (IROFS) INOPERABLE

The following information was provided by the licensee via phone and email:

"At approximately 2345 MDT, on 4/1/2024, it was observed that the physical boundary of IROFS10 had been opened while this boundary was being relied upon to perform its safety function. This initial report is being made as a 1-hour notification under Appendix A to 10 CFR70 (a)(4). The boundary (an isolation valve) was partially opened inadvertently by contact with adjacent equipment while performing operation of 1003 liquid sampling autoclave. The partially opened valve has been shut, restoring the IROFS10 boundary, and the autoclave has been placed in cooling mode. Out of conservatism, until an extent of condition can be performed, the 1004 autoclave which has a similar design has been taken out of service and placed in cooling mode as well.

"There has been no indication of leakage from any operating liquid sampling autoclave to the environment. The system and plant are in a stable condition."

The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:

The isolation valve was open less than 30 seconds and there was no exposures to personnel. The licensee will notify the NRC Region.


* * * RETRACTION ON 4/18/2024 AT 1029 EDT FROM JIM RICKMAN TO BILL GOTT * * *

"The potential leakage through the open boundary has been determined. The valve, if fully open, would not result in exceeding the 10 CFR 70.61 performance requirements. Thus, the 10 CFR 70 (a)(4) reporting requirement was not met, and this event notification is retracted."

Notified R2DO (Miller) and NMSS Events Notification (email).


Agreement State
Event Number: 57071
Rep Org: Alabama Radiation Control
Licensee: Alabama River Cellulose, LLC
Region: 1
City: Perdue Hill   State: AL
County:
License #: Alabama RML 634
Agreement: Y
Docket:
NRC Notified By: Cason Coan
HQ OPS Officer: Sam Colvard
Notification Date: 04/12/2024
Notification Time: 12:05 [ET]
Event Date: 04/11/2024
Event Time: 15:00 [CDT]
Last Update Date: 04/12/2024
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Defrancisco, Anne (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - STUCK OPEN SHUTTER

The following is a summary of information received from the Alabama Office of Radiation Control via email:

On April 11, 2024, at 1500 CST, a device (Ohmart/Vega, SH-F1, Model A-2102, Source SN 9254GK, 100 mCi Cs-137) was discovered to have a stuck open shutter during routine shutter checks. The device is in place and operational. The area around the vessel on which the device is mounted has been barricaded and marked for no entry. The licensee's plan is to replace the source holder with a new one. The licensee is getting a quote for replacement and installation with an estimated repair date of May 10, 2024.


Agreement State
Event Number: 57073
Rep Org: SC Dept of Health & Env Control
Licensee: Medical University of South Carolina
Region: 1
City: Charleston   State: SC
County:
License #: 081
Agreement: Y
Docket:
NRC Notified By: Korina Koci
HQ OPS Officer: Ernest West
Notification Date: 04/12/2024
Notification Time: 13:53 [ET]
Event Date: 04/12/2024
Event Time: 11:30 [EDT]
Last Update Date: 04/12/2024
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Defrancisco, Anne (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE - MEDICAL UNDERDOSE

The following information was provided by the South Carolina Department of Health and Environmental Control (Department) via email:

"The South Carolina Department of Health and Environmental Control was notified via telephone at approximately 1301 [EDT] on 4/12/24, that a medical event had been discovered by the licensee on 4/12/24 at approximately 1130 [EDT]. The Medical University of South Carolina (MUSC) reports an underdose to a patient's liver during a Y-90 microsphere procedure by 78 percent of the prescribed 120 Gray (Gy) dose. The licensee estimates that the patient received 27 Gy, which is 22 percent of the intended 120 Gy dose. The licensee reports that the total dose or activity delivered differs from the prescribed dose or activity, as documented in the written directive, by 20 percent or more. The patient was notified of this medical event verbally.

"The licensee reports no immediate or ongoing concerns to public health and safety. Department inspectors will be dispatched to the facility to investigate this event. This event is still under investigation by the South Carolina Department of Health and Environmental Control."


A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.


Agreement State
Event Number: 57074
Rep Org: Colorado Dept of Health
Licensee: Brighton United Methodist Church
Region: 4
City: Brighton   State: CO
County:
License #: GL002235
Agreement: Y
Docket:
NRC Notified By: Kathryn Kirk
HQ OPS Officer: Ernest West
Notification Date: 04/12/2024
Notification Time: 16:43 [ET]
Event Date: 04/12/2024
Event Time: 00:00 [MDT]
Last Update Date: 04/12/2024
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Azua, Ray (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
Event Text
AGREEMENT STATE REPORT - LOST EXIT SIGNS

The following is a summary of information received from the Colorado Department of Public Health and Environment via email:

Two SRB Technologies exit signs, model number: BX10GY, containing 10 curies each, of tritium (20 curies total) were determined to be lost by the licensee.

Colorado event number CO240010


THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Part 21
Event Number: 57079
Rep Org: Paragon Energy Solutions
Licensee:
Region: 2
City: Fort Worth   State: TX
County:
License #:
Agreement: N
Docket:
NRC Notified By: Richard Knott
HQ OPS Officer: Bill Gott
Notification Date: 04/16/2024
Notification Time: 23:29 [ET]
Event Date: 02/15/2024
Event Time: 00:00 [CDT]
Last Update Date: 04/17/2024
Emergency Class: Non Emergency
10 CFR Section:
21.21(a)(2) - Interim Eval Of Deviation
Person (Organization):
Franke, Mark (R2DO)
Part 21/50.55 Reactors (EMAIL)
Event Text
INITIAL PART 21 REPORT - POTENTIAL DEFECT WITH CIRCUIT BREAKER

The following information was provided by the licensee via email:

"Pursuant to 10CFR 21.21 (a)(2), Paragon Energy Solutions, LLC is providing this interim notification of ongoing analysis for Part 21 reportability of a potential defect with a Schneider Electric Medium Voltage VR Type Circuit Breaker Part Number V5D4133Y000.

"On February 15, 2024, Paragon completed initial documentation of a potential defect with the subject circuit breaker in which Duke-Oconee had identified failure to close on demand or delayed operation to close with extended application of the remote closing signal. Since the primary safety function of the circuit breaker is to close and maintain continuity of power to downstream loads, failure to close could potentially contribute to a substantial safety hazard.

"This is the first reported instance of this failure mode, and Paragon suspects the issue to be related to aging of the circuit breaker's lubrication. Paragon requires more time to complete testing and analysis to confirm the failure mode and determine reportability.

"Date when evaluation is expected to be complete: 5/03/2024."

Affected licensee: Oconee. Paragon is currently evaluating the extent of condition as it pertains to other plants and equipment that may utilize the same or similar circuit breakers.


Agreement State
Event Number: 57076
Rep Org: Colorado Dept of Health
Licensee: Nondestructive & Visual Inspection
Region: 4
City: Northglenn   State: CO
County:
License #: CO1241-01
Agreement: Y
Docket:
NRC Notified By: Carrie Romanchek
HQ OPS Officer: Sam Colvard
Notification Date: 04/15/2024
Notification Time: 12:28 [ET]
Event Date: 03/24/2024
Event Time: 00:00 [MDT]
Last Update Date: 04/15/2024
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Young, Cale (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - BROKEN LOCK ON RADIOGRAPHY CAMERA

The following information was received from the Colorado Department of Public Health and Environment via email:

"This letter is serving as notification of an equipment failure under [Colorado Regulation] Section 4.52.2.3 and 5.38.1.3. A QSA Global 880 Delta camera was received from Source Production and Equipment Company, Inc. (SPEC), after being resourced. During the check-in procedure and mechanism check, it was discovered that the lock that controls access to the pigtail attachment was broken in the locked position. The camera was tagged out until it could be sent to Industrial Nuclear Company (INC), for repairs on 04/04/2024. The lock was repaired at INC, and the camera was returned to the licensee on 04/10/2024 with no issues."

Colorado Event Report ID: CO240011


Power Reactor
Event Number: 57083
Facility: LaSalle
Region: 3     State: IL
Unit: [1] [] []
RX Type: [1] GE-5,[2] GE-5
NRC Notified By: Kelsey Smith
HQ OPS Officer: Tenisha Meadows
Notification Date: 04/20/2024
Notification Time: 13:51 [ET]
Event Date: 04/20/2024
Event Time: 07:04 [CDT]
Last Update Date: 04/20/2024
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
Person (Organization):
Betancourt-Roldan, Diana (R3DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
AUTOMATIC ACTUATION OF EMERGENCY DIESEL GENERATORS

The following information was provided by the licensee via phone and email:

"At 0704 CDT on 4/20/24 with Unit 1 in Mode 1 at 100 percent power, an actuation of the emergency AC power system, specifically the Division 1 and Division 3 emergency diesel generators (EDGs) occurred during an unexpected loss of the Unit 1 system auxiliary transformer (SAT). The cause of the emergency AC power system auto-start was an unexpected loss of the Unit 1 SAT during switchyard maintenance. Bus 141Y did not fast transfer as designed resulting in the actuation of the Division 1 EDG. Division 3 EDG actuation is expected for this condition. The Division 1 and Division 3 EDGs automatically started as designed when the emergency AC power system valid actuation signal was received.

"This event is being reported in accordance with 10 CFR 50.72(b)(3)(iv)(A) as an event that results in a valid actuation of the emergency AC power system.

"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."

The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:

Division 1 and Division 3 EDGs will remain in operation and loaded until the Unit 1 SAT is restored. This event resulted in the plant entering an unplanned 72 hour limiting condition for operation (LCO) in accordance with technical specification 3.8.1. The licensee is investigating the cause of the unexpected loss of the Unit 1 SAT and the failure of the bus 141Y fast transfer.