Skip to main content

Event Notification Report for February 14, 2024

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
02/13/2024 - 02/14/2024

EVENT NUMBERS
569655696656967
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Hospital
Event Number: 56965
Rep Org: Trinity Health of New England Medical Group - GHC Nuclear Laboratory
Licensee: Trinity Health of New England Medical Group - GHC Nuclear
Region: 1
City: Hartford   State: CT
County:
License #: 06-30812-01
Agreement: N
Docket:
NRC Notified By: Dr. Gladys Kagaoan
HQ OPS Officer: Natalie Starfish
Notification Date: 02/14/2024
Notification Time: 16:17 [ET]
Event Date: 02/14/2024
Event Time: 11:10 [EST]
Last Update Date: 02/15/2024
Emergency Class: Non Emergency
10 CFR Section:
35.3045(a)(3) - Dose To Other Site > Specified Limits
Person (Organization):
Bickett, Carey (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Williams, Kevin (NMSS)
Event Text
MEDICAL EVENT - DOSE MISADMINISTRATION

The following is a summary of information provided by the licensee via phone:

At 1110 EST on February 14, 2024, a patient was administered the wrong radiopharmaceutical. The prescribed dose was 25 mCi Tc-99m pyrophosphate, and the administered dose was 25 mCi Tc-99m sestamibi. The patient and referring physician were informed. There were no adverse effects to the patient. The total effective dose equivalent for this study was estimated to be 1,200 mrem.

* * * RETRACTION ON 2/15/24 AT 1240 EDT FROM GLADYS KAGAOAN TO ADAM KOZIOL * * *

After further review, the dose to the patient was below reporting threshold. The radiopharmaceutical was a diagnostic tracer and non-therapeutic.

Notified R1DO (Bickett), NMSS (Rivera-Capella), and NMSS Events (email).

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient


Agreement State
Event Number: 56966
Rep Org: New Mexico Rad Control Program
Licensee: NextTier
Region: 4
City:   State: NM
County: Eddy
License #: GA 507
Agreement: Y
Docket:
NRC Notified By: Robert Bicknell
HQ OPS Officer: Natalie Starfish
Notification Date: 02/14/2024
Notification Time: 13:53 [ET]
Event Date: 02/14/2024
Event Time: 11:10 [MST]
Last Update Date: 02/14/2024
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Vossmar, Patricia (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - SHUTTER STUCK OPEN

The following is a summary of information provided by the New Mexico Radiation Control Bureau via email:

On February 14, 2024, a routine inspection discovered that a densitometer (Berthold LB8010, serial number 10377, 20 mCi of cesium-137) was missing the handle that actuates the shutter. The shutter was in the open position. The radiation safety officer packed the defective densitometer in lead pending disposal. There were no excessive exposures due to this event.


Agreement State
Event Number: 56967
Rep Org: Colorado Dept of Health
Licensee: CTL/Thompson, Inc.
Region: 4
City: Pueblo   State: CO
County:
License #: CO 180-01
Agreement: Y
Docket:
NRC Notified By: Matt Gift
HQ OPS Officer: Tenisha Meadows
Notification Date: 02/14/2024
Notification Time: 15:58 [ET]
Event Date: 02/14/2024
Event Time: 10:30 [MST]
Last Update Date: 02/14/2024
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Vossmar, Patricia (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
Event Text
AGREEMENT STATE REPORT - STOLEN PORTABLE GAUGE

The following was received from the Colorado Department of Public Health and Environment (the Department) via email:

"On February 14, 2024, the radiation safety officer of CTL/Thompson, Inc. reported a stolen InstroTek model 3500 series portable moisture/density gauge (Serial Number 4764). The gauge user reported they loaded the gauge at their Pueblo office and stopped at their residence to retrieve their wallet. Upon returning to their truck, both chains that secured the gauge and transportation case were cut and the gauge and transportation case were stolen. The gauge contained a 10 mCi cesium-137 source (Serial Number BG1770) and a 40 mCi americium-241: beryllium source (K147/22).The licensee was instructed to file a police report. The Department is waiting for additional details regarding the event."

CO Event Number: CO240003

THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf