Event Notification Report for January 03, 2024
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
01/02/2024 - 01/03/2024
Agreement State
Event Number: 56703
Rep Org: Kentucky Dept of Radiation Control
Licensee: Univ of Kentucky Broadscope Medical
Region: 1
City: Lexington State: KY
County:
License #: 202-049-22
Agreement: Y
Docket:
NRC Notified By: Russell Hestand
HQ OPS Officer: Karen Cotton-Gross
Licensee: Univ of Kentucky Broadscope Medical
Region: 1
City: Lexington State: KY
County:
License #: 202-049-22
Agreement: Y
Docket:
NRC Notified By: Russell Hestand
HQ OPS Officer: Karen Cotton-Gross
Notification Date: 08/31/2023
Notification Time: 08:22 [ET]
Event Date: 08/30/2023
Event Time: 10:00 [CDT]
Last Update Date: 01/02/2024
Notification Time: 08:22 [ET]
Event Date: 08/30/2023
Event Time: 10:00 [CDT]
Last Update Date: 01/02/2024
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Young, Matt (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Young, Matt (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
EN Revision Imported Date: 1/3/2024
EN Revision Text: AGREEMENT STATE REPORT - MEDICAL UNDERDOSE
The following information was provided by the Kentucky Department for Public Health and Safety, Radiation Health Branch (KY RHB) via email:
"KY RHB was notified on 8/30/2023, at 1700 CDT, by a representative from University of Kentucky Broadscope Medical, of an underdose of a patient during a lutetium 177 (Lu-177) treatment. The underdosing was due to a leakage in the administration line.
"The underdosing was considered more than 20 percent. There was no harm to the patient. A separate report will be submitted once all the facts are gathered."
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
* * * UPDATE FROM RUSSELL HESTAND TO BRIAN P. SMITH AT 1229 EST ON JANUARY 2, 2024 * * *
The following summary of information was provided by the Kentucky Department of Public Health and Safety, Radiation Health Branch (KY RHB) via email and phone:
Further pertinent information regarding the medical event on Wednesday, August 30, 2023 at Chandler Hospital was identified per KY RHB's 15 day report. The event involved an administration of 200 mCi of Lutathera (Lu-177) via syringe pump where a leak was identified during the infusion. At approximately 20 minutes into the infusion the patient reported a wet feeling on their hand. The infusion was halted immediately. It was identified that a small volume of radioactive liquid was present on the patient's hand having dripped down onto it. The site of the leak was identified to be the connection between the syringe pump apparatus and the patient. Bedding and materials adjacent to the patient were found to have absorbed the majority of the leaked material, though some had also leaked onto the floor coverings. Spill response procedures were immediately initiated as well as notification to the authorized user (AU). Approximately 1/3 of the prescribed activity remained in the syringe. The AU elected to have a new connection established and administer the remainder to the patient.
The licensee estimated the administered activity based on volume of the drug administered, measurements of the contaminated bedding materials, and patient dose rate measurements post infusion (corrected for BMI). These estimates all suggest that this incident resulted in an underdose of approximately 25 percent to 30 percent due to the lost material from the leak. The skin dose to the patient's hand was estimated to conservatively be less than 10 rem (100 mSv). This is well below the level at which any tissue reaction is expected to occur.
Notified R1DO (Bickett), NMSS (Rivera-Capella), NMSS Events Notification (email)
NMED Event Number: 230360
EN Revision Text: AGREEMENT STATE REPORT - MEDICAL UNDERDOSE
The following information was provided by the Kentucky Department for Public Health and Safety, Radiation Health Branch (KY RHB) via email:
"KY RHB was notified on 8/30/2023, at 1700 CDT, by a representative from University of Kentucky Broadscope Medical, of an underdose of a patient during a lutetium 177 (Lu-177) treatment. The underdosing was due to a leakage in the administration line.
"The underdosing was considered more than 20 percent. There was no harm to the patient. A separate report will be submitted once all the facts are gathered."
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
* * * UPDATE FROM RUSSELL HESTAND TO BRIAN P. SMITH AT 1229 EST ON JANUARY 2, 2024 * * *
The following summary of information was provided by the Kentucky Department of Public Health and Safety, Radiation Health Branch (KY RHB) via email and phone:
Further pertinent information regarding the medical event on Wednesday, August 30, 2023 at Chandler Hospital was identified per KY RHB's 15 day report. The event involved an administration of 200 mCi of Lutathera (Lu-177) via syringe pump where a leak was identified during the infusion. At approximately 20 minutes into the infusion the patient reported a wet feeling on their hand. The infusion was halted immediately. It was identified that a small volume of radioactive liquid was present on the patient's hand having dripped down onto it. The site of the leak was identified to be the connection between the syringe pump apparatus and the patient. Bedding and materials adjacent to the patient were found to have absorbed the majority of the leaked material, though some had also leaked onto the floor coverings. Spill response procedures were immediately initiated as well as notification to the authorized user (AU). Approximately 1/3 of the prescribed activity remained in the syringe. The AU elected to have a new connection established and administer the remainder to the patient.
The licensee estimated the administered activity based on volume of the drug administered, measurements of the contaminated bedding materials, and patient dose rate measurements post infusion (corrected for BMI). These estimates all suggest that this incident resulted in an underdose of approximately 25 percent to 30 percent due to the lost material from the leak. The skin dose to the patient's hand was estimated to conservatively be less than 10 rem (100 mSv). This is well below the level at which any tissue reaction is expected to occur.
Notified R1DO (Bickett), NMSS (Rivera-Capella), NMSS Events Notification (email)
NMED Event Number: 230360
Non-Agreement State
Event Number: 56909
Rep Org: Rock Island Arsenal
Licensee: Rock Island Arsenal
Region: 3
City: Rock Island State: IL
County:
License #: 12-00722-15
Agreement: N
Docket:
NRC Notified By: Michael Kurth
HQ OPS Officer: Adam Koziol
Licensee: Rock Island Arsenal
Region: 3
City: Rock Island State: IL
County:
License #: 12-00722-15
Agreement: N
Docket:
NRC Notified By: Michael Kurth
HQ OPS Officer: Adam Koziol
Notification Date: 12/28/2023
Notification Time: 12:20 [ET]
Event Date: 11/28/2023
Event Time: 00:00 [CST]
Last Update Date: 12/28/2023
Notification Time: 12:20 [ET]
Event Date: 11/28/2023
Event Time: 00:00 [CST]
Last Update Date: 12/28/2023
Emergency Class: Non Emergency
10 CFR Section:
20.2201(a)(1)(ii) - Lost/Stolen LNM>10x
10 CFR Section:
20.2201(a)(1)(ii) - Lost/Stolen LNM>10x
Person (Organization):
Ruiz, Robert (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Henrion, Mark (R1DO)
Ruiz, Robert (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Henrion, Mark (R1DO)
FOUND DEPLETED URANIUM PROJECTILE
The following information was provided by the licensee via email:
"In accordance with 10 CFR 20.2201 (a)(1)(ii), the US Army is (telephone) reporting the recovery of a 120 mm depleted uranium (DU) projectile from a landfill in York, PA. [10 CFR 20.2201(a)(1)(ii) - Within 30 days after the occurrence of any lost, stolen, or missing licensed material becomes known to the licensee, all licensed material in a quantity greater than 10 times the quantity specified in appendix C to Part 20 that is still missing at this time.]
"An M829 120 mm DU projectile has 4000 grams of DU, which equates to approximately 1,520 microcuries of U-238. The M829 DU projectile was manufactured in the 1970's - 1980's.
"The Part 20 App C limit for U-238 is 100 microcuries. 100 microcuries times 10 equals 1,000 microcuries.
"The specifics on retrieving the 120 mm DU projectile are as follows:
1. A military explosive ordnance disposal (EOD) team was contacted (Nov 28) and requested to respond to a possible unexploded ordnance (UXO) device at the York County Resource Recovery Center, York, Pennsylvania.
2. The EOD team arrived (Nov 28) and identified the UXO as a 120 mm DU projectile (projectile with tailfin, no propellant, no cartridge case, no explosives, no tracer).
3. EOD placed the item in an ammo storage container and transported the item to Joint Base McGuire-Dix-Lakehurst, New Jersey for safe storage.
4. US Army Joint Munitions Command DoD Low Level Radioactive Waste (LLRW) Lead Agent was notified on or about December 1.
5. A member of the LLRW team is at Joint Base McGuire-Dix-Lakehurst on December 27-28 to package and ship the DU projectile to our Morris Consolidation Facility (NRC License 12-00722-15), Rock Island Arsenal, Rock Island, IL, for safe storage and eventual disposal.
6. At this time, we have no further information or evidence to determine how the item arrived at the Pennsylvania landfill.
7. There are no clear identification markings that we have viewed on pictures (so far) that will help us to determine where the device was stored or possessed. We will conduct a more thorough visual exam once we have the item in our possession at our Rock Island Arsenal facility (Morris Consolidation Facility).
"In accordance with 10 CFR 20.2201 (b), a written report will be provided to the NRC within 30 days after making the telephone report."
The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:
Swipe test of the ordinance revealed no loose contamination. Dose rate on contact is 1-2 mrem/hr, so exposure exceeding limits to public is unlikely.
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following information was provided by the licensee via email:
"In accordance with 10 CFR 20.2201 (a)(1)(ii), the US Army is (telephone) reporting the recovery of a 120 mm depleted uranium (DU) projectile from a landfill in York, PA. [10 CFR 20.2201(a)(1)(ii) - Within 30 days after the occurrence of any lost, stolen, or missing licensed material becomes known to the licensee, all licensed material in a quantity greater than 10 times the quantity specified in appendix C to Part 20 that is still missing at this time.]
"An M829 120 mm DU projectile has 4000 grams of DU, which equates to approximately 1,520 microcuries of U-238. The M829 DU projectile was manufactured in the 1970's - 1980's.
"The Part 20 App C limit for U-238 is 100 microcuries. 100 microcuries times 10 equals 1,000 microcuries.
"The specifics on retrieving the 120 mm DU projectile are as follows:
1. A military explosive ordnance disposal (EOD) team was contacted (Nov 28) and requested to respond to a possible unexploded ordnance (UXO) device at the York County Resource Recovery Center, York, Pennsylvania.
2. The EOD team arrived (Nov 28) and identified the UXO as a 120 mm DU projectile (projectile with tailfin, no propellant, no cartridge case, no explosives, no tracer).
3. EOD placed the item in an ammo storage container and transported the item to Joint Base McGuire-Dix-Lakehurst, New Jersey for safe storage.
4. US Army Joint Munitions Command DoD Low Level Radioactive Waste (LLRW) Lead Agent was notified on or about December 1.
5. A member of the LLRW team is at Joint Base McGuire-Dix-Lakehurst on December 27-28 to package and ship the DU projectile to our Morris Consolidation Facility (NRC License 12-00722-15), Rock Island Arsenal, Rock Island, IL, for safe storage and eventual disposal.
6. At this time, we have no further information or evidence to determine how the item arrived at the Pennsylvania landfill.
7. There are no clear identification markings that we have viewed on pictures (so far) that will help us to determine where the device was stored or possessed. We will conduct a more thorough visual exam once we have the item in our possession at our Rock Island Arsenal facility (Morris Consolidation Facility).
"In accordance with 10 CFR 20.2201 (b), a written report will be provided to the NRC within 30 days after making the telephone report."
The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:
Swipe test of the ordinance revealed no loose contamination. Dose rate on contact is 1-2 mrem/hr, so exposure exceeding limits to public is unlikely.
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Power Reactor
Event Number: 56912
Facility: Saint Lucie
Region: 2 State: FL
Unit: [2] [] []
RX Type: [1] CE,[2] CE
NRC Notified By: Eric Laettner
HQ OPS Officer: Brian Parks
Region: 2 State: FL
Unit: [2] [] []
RX Type: [1] CE,[2] CE
NRC Notified By: Eric Laettner
HQ OPS Officer: Brian Parks
Notification Date: 01/03/2024
Notification Time: 15:38 [ET]
Event Date: 01/03/2024
Event Time: 12:57 [EST]
Last Update Date: 01/03/2024
Notification Time: 15:38 [ET]
Event Date: 01/03/2024
Event Time: 12:57 [EST]
Last Update Date: 01/03/2024
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(ii)(A) - Degraded Condition 50.72(b)(3)(v)(D) - Accident Mitigation
10 CFR Section:
50.72(b)(3)(ii)(A) - Degraded Condition 50.72(b)(3)(v)(D) - Accident Mitigation
Person (Organization):
Miller, Mark (R2DO)
Miller, Mark (R2DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | N | 0 | Power Operation | 0 | Power Operation |
PRESSURE BOUNDARY DEGRADED / BOTH TRAINS OF HIGH PRESSURE SAFETY INJECTION INOPERABLE
"At 1257 EST on January 3, 2024, it was determined that a class 1 system barrier had a through wall flaw with leakage. The leakage renders both trains of high pressure safety injection inoperable. The unit is being cooled down to cold shutdown to comply with technical specifications.
"This event is being reported pursuant to 10 CFR 50.72(b)(3)(ii)(A) and 10 CFR 50.72(b)(3)(v)(D).
"The NRC Resident Inspector has been notified."
The following additional information was obtained from the licensee in accordance with Headquarters Operations Officer Report Guidance:
At the time of the discovery, the unit was shutdown in mode 3. The unit was experiencing signs of reactor coolant system leakage and a shutdown was initiated in order to search for possible sources. The unit is currently cooling down and proceeding to mode 5, where the safety function is not required.
"At 1257 EST on January 3, 2024, it was determined that a class 1 system barrier had a through wall flaw with leakage. The leakage renders both trains of high pressure safety injection inoperable. The unit is being cooled down to cold shutdown to comply with technical specifications.
"This event is being reported pursuant to 10 CFR 50.72(b)(3)(ii)(A) and 10 CFR 50.72(b)(3)(v)(D).
"The NRC Resident Inspector has been notified."
The following additional information was obtained from the licensee in accordance with Headquarters Operations Officer Report Guidance:
At the time of the discovery, the unit was shutdown in mode 3. The unit was experiencing signs of reactor coolant system leakage and a shutdown was initiated in order to search for possible sources. The unit is currently cooling down and proceeding to mode 5, where the safety function is not required.