Event Notification Report for December 08, 2022
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
12/07/2022 - 12/08/2022
Agreement State
Event Number: 56246
Rep Org: Colorado Dept of Health
Licensee: LDS Church - Fort Morgan
Region: 4
City: Fort Morgan State: CO
County:
License #: GL000986
Agreement: Y
Docket:
NRC Notified By: Kathryn Kirk
HQ OPS Officer: Lloyd Desotell
Licensee: LDS Church - Fort Morgan
Region: 4
City: Fort Morgan State: CO
County:
License #: GL000986
Agreement: Y
Docket:
NRC Notified By: Kathryn Kirk
HQ OPS Officer: Lloyd Desotell
Notification Date: 11/30/2022
Notification Time: 12:25 [ET]
Event Date: 11/18/2022
Event Time: 00:00 [MST]
Last Update Date: 11/30/2022
Notification Time: 12:25 [ET]
Event Date: 11/18/2022
Event Time: 00:00 [MST]
Last Update Date: 11/30/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Vossmar, Patricia (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL)
Vossmar, Patricia (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL)
AGREEMENT STATE REPORT - LOST EXIT SIGNS
The following information was provided by the Colorado Department of Public Health and Environment via email:
The licensee discovered four tritium exit signs were lost. The exit signs are Isolite Corporation model 2040-50G-20WH signs containing 11.5 Ci of tritium (H-3) each. This is being reported under Colorado Regulations Section 4.51.1.1 (10 CFR 20.2202(a)(1)(i)).
Colorado Incident No.: CO220042
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following information was provided by the Colorado Department of Public Health and Environment via email:
The licensee discovered four tritium exit signs were lost. The exit signs are Isolite Corporation model 2040-50G-20WH signs containing 11.5 Ci of tritium (H-3) each. This is being reported under Colorado Regulations Section 4.51.1.1 (10 CFR 20.2202(a)(1)(i)).
Colorado Incident No.: CO220042
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 56248
Rep Org: Texas Dept of State Health Services
Licensee: GRAPHIC PACKAGING INTERNATIONAL LLC
Region: 4
City: Queen City State: TX
County:
License #: L06934
Agreement: Y
Docket:
NRC Notified By: Arthur Tucker
HQ OPS Officer: Ernest West
Licensee: GRAPHIC PACKAGING INTERNATIONAL LLC
Region: 4
City: Queen City State: TX
County:
License #: L06934
Agreement: Y
Docket:
NRC Notified By: Arthur Tucker
HQ OPS Officer: Ernest West
Notification Date: 11/30/2022
Notification Time: 17:19 [ET]
Event Date: 11/30/2022
Event Time: 00:00 [CST]
Last Update Date: 12/01/2022
Notification Time: 17:19 [ET]
Event Date: 11/30/2022
Event Time: 00:00 [CST]
Last Update Date: 12/01/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Vossmar, Patricia (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Vossmar, Patricia (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - STUCK SHUTTER
The following information was provided by the Texas Department of State Health Services (the Agency) via email:
"On November 30, 2022, the Agency was notified by the licensee's radiation safety officer (RSO) that during routine testing the shutter on a Berthold model LB7440 nuclear gauge the shutter failed to close. The gauge shutter is in the open position, which is the normal operating position. The gauge contains a 30 millicurie Cesium - 137 source. The RSO stated the roll pin on the shutter operating arm had broken. The manufacturer has been contacted to repair the gauge. The RSO stated dose rates around the gauge were normal. No individual received any additional exposure as a result of this event. The gauge does not pose an exposure risk. Additional information will be provided as it is received in accordance with SA-300."
Texas Incident Number: 9968
The following information was provided by the Texas Department of State Health Services (the Agency) via email:
"On November 30, 2022, the Agency was notified by the licensee's radiation safety officer (RSO) that during routine testing the shutter on a Berthold model LB7440 nuclear gauge the shutter failed to close. The gauge shutter is in the open position, which is the normal operating position. The gauge contains a 30 millicurie Cesium - 137 source. The RSO stated the roll pin on the shutter operating arm had broken. The manufacturer has been contacted to repair the gauge. The RSO stated dose rates around the gauge were normal. No individual received any additional exposure as a result of this event. The gauge does not pose an exposure risk. Additional information will be provided as it is received in accordance with SA-300."
Texas Incident Number: 9968
Agreement State
Event Number: 56249
Rep Org: Maryland Dept of the Environment
Licensee: Morgantown Generation Station
Region: 1
City: Newburg State: MD
County:
License #: MD-17-027-01
Agreement: Y
Docket:
NRC Notified By: Paul Kovach
HQ OPS Officer: Lloyd Desotell
Licensee: Morgantown Generation Station
Region: 1
City: Newburg State: MD
County:
License #: MD-17-027-01
Agreement: Y
Docket:
NRC Notified By: Paul Kovach
HQ OPS Officer: Lloyd Desotell
Notification Date: 11/30/2022
Notification Time: 18:11 [ET]
Event Date: 11/30/2022
Event Time: 11:21 [EST]
Last Update Date: 12/02/2022
Notification Time: 18:11 [ET]
Event Date: 11/30/2022
Event Time: 11:21 [EST]
Last Update Date: 12/02/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Cahill, Christopher (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
MacDonald, Mark (ILTAB)
Cahill, Christopher (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
MacDonald, Mark (ILTAB)
AGREEMENT STATE REPORT - MISSING OR POSSIBLY LOST GAUGE SOURCES
The following information was received from the state of Maryland via email:
"A Maryland Department of the Environment (MDE) radioactive materials inspector was performing a close-out survey in support of license termination. The facility is no longer operating with radioactive materials (RAM) and some essential staff are gone. The inspector found that three Cf-252 sources for installed gauges had been changed out. The licensee was unable to provide records for the disposal of the old sources, which are no longer present, the new sources were accounted for.
"The sources of concern are:
"Cf-252; serial # FTC-CF-Z3384; 5.2 Ci Assay date missing. Installed October 2009. Decay corrected activity to November 2022 = about 165mCi or less
"Cf-252; serial # FTC-CF-Z3383; 5.2 Ci Assay date missing. Installed October 2009. Decay corrected activity to November 2022 = about 165mCi or less
"Cf-252; serial # FTC-CF-Z3930: 5.2 Ci Assay date missing. Installed October 2009. Decay corrected activity to November 2022 = about 165mCi or less
"Total Activity: about 495 mCi or less
"The licensee is continuing the search for records of these sources. It does not appear to the licensee that an exposure could result to persons in unrestricted areas. The licensee believes that the sources were sent to ThermoFisher Scientific and is attempting to confirm. MDE is providing this precautionary notification pursuant to 10 CFR 2201(a)(1) using the best available information on the radioactive sources."
* * * UPDATE ON 12/1/2022 AT 1622 EST FROM MDE TO ERNEST WEST * * *
Updated activities for sources of concern and results of search for the sources are as follows:
"Cf-252; serial # FTC-CF-Z3384; 10.8 mCi on 25 September 2010. Decay corrected activity November 2022 = 445 microcuries
"Cf-252; serial # FTC-CF-Z3383; 10.8 mCi on 25 September 2010. Decay corrected activity November 2022 = 445 microcuries
"Cf-252; serial # FTC-CF-Z3930: 10.8 mCi on 25 September 2010. Decay corrected activity November 2022 = 445 microcuries
"Total Estimated Current Activity: 1.335 mCi
"The licensee is continuing to search for disposal records for these sources or the sources themselves. It does not appear to the licensee that an exposure could result to persons in unrestricted areas. The supplier, ThermoFisher Scientific, has confirmed that they do not have the sources. The waste disposer, RAM Services, is attempting to confirm their possession or the possibility that the sources remain in the gauge housing. MDE is providing this precautionary notification pursuant to 10 CFR 2201(a)(1) using the best available information at the time. This report principally revises source activities using information from the supplier and continuing efforts of the supplier and waste disposer."
Notified R1DO (Cahill), NMSS Events Notification, and ILTAB via email.
* * * UPDATE ON 12/2/2022 AT 1852 EST FROM MDE TO BILL GOTT * * *
"An MDE radioactive materials inspector was performing a close-out survey in support of license termination. The facility is no longer operating with RAM and some essential staff are gone. All RAM sources had been reportedly removed and disposed. The inspector found that three Cf-252 sources from three installed process gauges had been replenished in the past. Each gauge contained one Cf-252 and one Cs-137 source; the Cs-137 are not normally replaced because of their long half-life. The licensee was unable to provide records for the disposal of the three old Cf-252 sources which were no longer present; the three new Cf-252 sources were accounted for. The sources of concern are:
"Cf-252; serial # FTC-CF-Z3384; 10.8 mCi on 25 September 2010. Decay corrected activity Nov 2022 = 445 microCuries
"Cf-252; serial # FTC-CF-Z3383; 10.8 mCi on 25 September 2010. Decay corrected activity Nov 2022 = 445 microCuries
"Cf-252; serial # FTC-CF-Z3930: 10.8 mCi on 25 September 2010. Decay corrected activity Nov 2022 = 445 microCuries
"Total Estimated Current Activity: 1.335 mCi
"The licensee and vendors continued to search for disposal records for these sources or the sources themselves. At no time did it appear to the licensee that an exposure could result to persons in unrestricted areas. A precautionary Event Report was made on 11/30/22 and updated on 12/01/22. On 12/02/2022 the waste disposer, RAM Services, confirmed by serial number that they have possession of the three old and three new Cf-252 sources in a neutron-shielded container in a secure, licensed facility in Wisconsin. The sources had been removed and misidentified when the gauges were de-sourced for license termination. The intended sources to be removed were three Cs-137 sources; these sources are presently unaccounted for and believed to be remaining in the gauges. The sources are:
"Cs-137; serial # CZ-2586; 30mCi on 10/01/2010. Decay corrected activity 12/01/2022 = 22.68 mCi
"Cs-137; serial # 0950/08; 30mCi on 10/01/2010. Decay corrected activity 12/01/2022 = 22.68 mCi"
"Cs-137; serial # 0949/08; 30mCi on 10/01/2010. Decayed corrected activity 12/01/2022 = 22.68 mCi
"Total Estimated Current Activity: 68.04 mCi
"It appears that the disposer had removed sources without actually verifying the serial numbers, isotopes, and activities of the sources, contrary to the records that were submitted. The source slots in the gauges are not visible and sources are moved remotely. The disposer will investigate and confirm or locate the three Cs-137 sources 12/05-12/09/2022. This is an update to the precautionary notification made 11/30/2022 pursuant to 10CFR 2201(a)(1) using the best available information currently available."
Notified R1DO (Cahill), NMSS Events Notification, and ILTAB via email.
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following information was received from the state of Maryland via email:
"A Maryland Department of the Environment (MDE) radioactive materials inspector was performing a close-out survey in support of license termination. The facility is no longer operating with radioactive materials (RAM) and some essential staff are gone. The inspector found that three Cf-252 sources for installed gauges had been changed out. The licensee was unable to provide records for the disposal of the old sources, which are no longer present, the new sources were accounted for.
"The sources of concern are:
"Cf-252; serial # FTC-CF-Z3384; 5.2 Ci Assay date missing. Installed October 2009. Decay corrected activity to November 2022 = about 165mCi or less
"Cf-252; serial # FTC-CF-Z3383; 5.2 Ci Assay date missing. Installed October 2009. Decay corrected activity to November 2022 = about 165mCi or less
"Cf-252; serial # FTC-CF-Z3930: 5.2 Ci Assay date missing. Installed October 2009. Decay corrected activity to November 2022 = about 165mCi or less
"Total Activity: about 495 mCi or less
"The licensee is continuing the search for records of these sources. It does not appear to the licensee that an exposure could result to persons in unrestricted areas. The licensee believes that the sources were sent to ThermoFisher Scientific and is attempting to confirm. MDE is providing this precautionary notification pursuant to 10 CFR 2201(a)(1) using the best available information on the radioactive sources."
* * * UPDATE ON 12/1/2022 AT 1622 EST FROM MDE TO ERNEST WEST * * *
Updated activities for sources of concern and results of search for the sources are as follows:
"Cf-252; serial # FTC-CF-Z3384; 10.8 mCi on 25 September 2010. Decay corrected activity November 2022 = 445 microcuries
"Cf-252; serial # FTC-CF-Z3383; 10.8 mCi on 25 September 2010. Decay corrected activity November 2022 = 445 microcuries
"Cf-252; serial # FTC-CF-Z3930: 10.8 mCi on 25 September 2010. Decay corrected activity November 2022 = 445 microcuries
"Total Estimated Current Activity: 1.335 mCi
"The licensee is continuing to search for disposal records for these sources or the sources themselves. It does not appear to the licensee that an exposure could result to persons in unrestricted areas. The supplier, ThermoFisher Scientific, has confirmed that they do not have the sources. The waste disposer, RAM Services, is attempting to confirm their possession or the possibility that the sources remain in the gauge housing. MDE is providing this precautionary notification pursuant to 10 CFR 2201(a)(1) using the best available information at the time. This report principally revises source activities using information from the supplier and continuing efforts of the supplier and waste disposer."
Notified R1DO (Cahill), NMSS Events Notification, and ILTAB via email.
* * * UPDATE ON 12/2/2022 AT 1852 EST FROM MDE TO BILL GOTT * * *
"An MDE radioactive materials inspector was performing a close-out survey in support of license termination. The facility is no longer operating with RAM and some essential staff are gone. All RAM sources had been reportedly removed and disposed. The inspector found that three Cf-252 sources from three installed process gauges had been replenished in the past. Each gauge contained one Cf-252 and one Cs-137 source; the Cs-137 are not normally replaced because of their long half-life. The licensee was unable to provide records for the disposal of the three old Cf-252 sources which were no longer present; the three new Cf-252 sources were accounted for. The sources of concern are:
"Cf-252; serial # FTC-CF-Z3384; 10.8 mCi on 25 September 2010. Decay corrected activity Nov 2022 = 445 microCuries
"Cf-252; serial # FTC-CF-Z3383; 10.8 mCi on 25 September 2010. Decay corrected activity Nov 2022 = 445 microCuries
"Cf-252; serial # FTC-CF-Z3930: 10.8 mCi on 25 September 2010. Decay corrected activity Nov 2022 = 445 microCuries
"Total Estimated Current Activity: 1.335 mCi
"The licensee and vendors continued to search for disposal records for these sources or the sources themselves. At no time did it appear to the licensee that an exposure could result to persons in unrestricted areas. A precautionary Event Report was made on 11/30/22 and updated on 12/01/22. On 12/02/2022 the waste disposer, RAM Services, confirmed by serial number that they have possession of the three old and three new Cf-252 sources in a neutron-shielded container in a secure, licensed facility in Wisconsin. The sources had been removed and misidentified when the gauges were de-sourced for license termination. The intended sources to be removed were three Cs-137 sources; these sources are presently unaccounted for and believed to be remaining in the gauges. The sources are:
"Cs-137; serial # CZ-2586; 30mCi on 10/01/2010. Decay corrected activity 12/01/2022 = 22.68 mCi
"Cs-137; serial # 0950/08; 30mCi on 10/01/2010. Decay corrected activity 12/01/2022 = 22.68 mCi"
"Cs-137; serial # 0949/08; 30mCi on 10/01/2010. Decayed corrected activity 12/01/2022 = 22.68 mCi
"Total Estimated Current Activity: 68.04 mCi
"It appears that the disposer had removed sources without actually verifying the serial numbers, isotopes, and activities of the sources, contrary to the records that were submitted. The source slots in the gauges are not visible and sources are moved remotely. The disposer will investigate and confirm or locate the three Cs-137 sources 12/05-12/09/2022. This is an update to the precautionary notification made 11/30/2022 pursuant to 10CFR 2201(a)(1) using the best available information currently available."
Notified R1DO (Cahill), NMSS Events Notification, and ILTAB via email.
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 56250
Rep Org: Ohio Bureau of Radiation Protection
Licensee: NDC Technologies, Inc.
Region: 3
City: Dayton State: OH
County:
License #: 03214580002
Agreement: Y
Docket:
NRC Notified By: Michael Snee
HQ OPS Officer: Ernest West
Licensee: NDC Technologies, Inc.
Region: 3
City: Dayton State: OH
County:
License #: 03214580002
Agreement: Y
Docket:
NRC Notified By: Michael Snee
HQ OPS Officer: Ernest West
Notification Date: 12/01/2022
Notification Time: 13:51 [ET]
Event Date: 09/28/2022
Event Time: 00:00 [EST]
Last Update Date: 12/01/2022
Notification Time: 13:51 [ET]
Event Date: 09/28/2022
Event Time: 00:00 [EST]
Last Update Date: 12/01/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Peterson, Hironori (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Peterson, Hironori (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - SOURCE INADVERTENTLY SHIPPED
The following information was provided by the Ohio Department of Health via email:
"[The] licensee (NDC Technologies, Inc.) inadvertently shipped a 150 mCi Am-241 source to a customer in Germany. Only the electronic portion of the gauge should have been shipped to that customer. The source was [intended] to be shipped separately to a separate licensed facility in Germany. The source was not handled at the facility in Germany and was immediately sent back. The source has arrived at the NDC facility in Dayton."
Ohio Reference Number: OH220012
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following information was provided by the Ohio Department of Health via email:
"[The] licensee (NDC Technologies, Inc.) inadvertently shipped a 150 mCi Am-241 source to a customer in Germany. Only the electronic portion of the gauge should have been shipped to that customer. The source was [intended] to be shipped separately to a separate licensed facility in Germany. The source was not handled at the facility in Germany and was immediately sent back. The source has arrived at the NDC facility in Dayton."
Ohio Reference Number: OH220012
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 56251
Rep Org: SC Dept of Health & Env Control
Licensee: Auriga Polymers, Inc.
Region: 1
City: Spartanburg State: SC
County:
License #: 059
Agreement: Y
Docket:
NRC Notified By: Andrew Roxburgh
HQ OPS Officer: Ernest West
Licensee: Auriga Polymers, Inc.
Region: 1
City: Spartanburg State: SC
County:
License #: 059
Agreement: Y
Docket:
NRC Notified By: Andrew Roxburgh
HQ OPS Officer: Ernest West
Notification Date: 12/01/2022
Notification Time: 14:24 [ET]
Event Date: 06/27/2022
Event Time: 00:00 [EST]
Last Update Date: 12/01/2022
Notification Time: 14:24 [ET]
Event Date: 06/27/2022
Event Time: 00:00 [EST]
Last Update Date: 12/01/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Cahill, Christopher (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Cahill, Christopher (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - DAMAGED GAUGE
The following information was provided by the South Carolina Department of Health and Environmental Control (the Department) via email:
"On December 1, 2022, at approximately 1400 [EST], the Department was notified by the licensee that its contracted vendor used to replace sources, damaged the threads while attempting to exchange sources on June 27th, 2022. The source is a Berthold Model SSC-100 containing 20 millicuries of Cobalt 60, source serial number 1359/10/21. The source is designed to be mounted onto a dip tube via the use of threads. The source remains in the shielded position on the vessel and the area is roped off. This incident is still under investigation."
South Carolina Event Number: To be announced.
The following information was provided by the South Carolina Department of Health and Environmental Control (the Department) via email:
"On December 1, 2022, at approximately 1400 [EST], the Department was notified by the licensee that its contracted vendor used to replace sources, damaged the threads while attempting to exchange sources on June 27th, 2022. The source is a Berthold Model SSC-100 containing 20 millicuries of Cobalt 60, source serial number 1359/10/21. The source is designed to be mounted onto a dip tube via the use of threads. The source remains in the shielded position on the vessel and the area is roped off. This incident is still under investigation."
South Carolina Event Number: To be announced.
Non-Agreement State
Event Number: 56253
Rep Org: Terracon
Licensee: Terracon
Region: 4
City: Olathe State: KS
County:
License #: 15-27070-01
Agreement: Y
Docket:
NRC Notified By: Adam Maier
HQ OPS Officer: Lloyd Desotell
Licensee: Terracon
Region: 4
City: Olathe State: KS
County:
License #: 15-27070-01
Agreement: Y
Docket:
NRC Notified By: Adam Maier
HQ OPS Officer: Lloyd Desotell
Notification Date: 12/01/2022
Notification Time: 17:49 [ET]
Event Date: 12/01/2022
Event Time: 09:30 [CST]
Last Update Date: 12/01/2022
Notification Time: 17:49 [ET]
Event Date: 12/01/2022
Event Time: 09:30 [CST]
Last Update Date: 12/01/2022
Emergency Class: Non Emergency
10 CFR Section:
20.2201(a)(1)(i) - Lost/Stolen LNM>1000x
10 CFR Section:
20.2201(a)(1)(i) - Lost/Stolen LNM>1000x
Person (Organization):
NMSS_EVENTS_NOTIFICATION (EMAIL)
Peterson, Hironori (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Peterson, Hironori (R3DO)
NON-AGREEMENT STATE REPORT - LOST AND RECOVERED RADIOACTIVE SOURCE
The following information is a summary of the information provided by the licensee via telephone and email:
While in transport from Grand Rapids, MI to Franklin, WI, a Troxler moisture density gauge fell off the trailer and into a median of I-94 near Coloma, MI. The gauge was discovered and secured by another company knowledgeable with gauge use until the licensee was able to retrieve it. The licensee has secured and transported the gauge to their office until a service provider can retrieve it. There is no indication that the gauge has leaked. The date the gauge fell off the trailer is unclear at this time. The gauge was in the control of a transportation service beginning 11/30/2022. The Michigan Department of Transportation and Michigan State Police have been notified of the event (complaint number 53-4067-22).
Gauge information:
Manufacturer: Troxler
Model: 3430
SN: 31413
Source Info:
Am241: serial number 47-1397 [nominal 40 mCi]
Cs137: serial number 750-6146 [nominal 8 mCi]
The following information is a summary of the information provided by the licensee via telephone and email:
While in transport from Grand Rapids, MI to Franklin, WI, a Troxler moisture density gauge fell off the trailer and into a median of I-94 near Coloma, MI. The gauge was discovered and secured by another company knowledgeable with gauge use until the licensee was able to retrieve it. The licensee has secured and transported the gauge to their office until a service provider can retrieve it. There is no indication that the gauge has leaked. The date the gauge fell off the trailer is unclear at this time. The gauge was in the control of a transportation service beginning 11/30/2022. The Michigan Department of Transportation and Michigan State Police have been notified of the event (complaint number 53-4067-22).
Gauge information:
Manufacturer: Troxler
Model: 3430
SN: 31413
Source Info:
Am241: serial number 47-1397 [nominal 40 mCi]
Cs137: serial number 750-6146 [nominal 8 mCi]
Agreement State
Event Number: 56205
Rep Org: New York State Dept. of Health
Licensee: Universal Testing & Inspection
Region: 1
City: Manhasset State: NY
County:
License #: C2570
Agreement: Y
Docket:
NRC Notified By: Daniel Samson
HQ OPS Officer: Karen Cotton-Gross
Licensee: Universal Testing & Inspection
Region: 1
City: Manhasset State: NY
County:
License #: C2570
Agreement: Y
Docket:
NRC Notified By: Daniel Samson
HQ OPS Officer: Karen Cotton-Gross
Notification Date: 11/04/2022
Notification Time: 12:33 [ET]
Event Date: 11/03/2022
Event Time: 14:30 [EDT]
Last Update Date: 12/08/2022
Notification Time: 12:33 [ET]
Event Date: 11/03/2022
Event Time: 14:30 [EDT]
Last Update Date: 12/08/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Lilliendahl, Jon (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
MacDonald, Mark (ILTAB)
CNSC (Canada), - (EMAIL)
Lilliendahl, Jon (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
MacDonald, Mark (ILTAB)
CNSC (Canada), - (EMAIL)
EN Revision Imported Date: 12/9/2022
EN Revision Text: AGREEMENT STATE REPORT - STOLEN MOISTURE DENSITY GAUGE
The following information was provided by the New York State Department of Health Bureau of Environmental Radiation Protection (NYSDOH BERP) via fax:
"On November 3, 2022, at approximately 1430 EDT, an authorized user for the licensee had finished conducting soils testing at a temporary job site located in Manhasset, NY and locked the moisture density device in the carrying case within the trunk of their vehicle. The authorized user was conducting concrete work while the gauge was locked in the trunk and returned to their vehicle later to find that the vehicle was stolen, with the gauge locked in the trunk. The authorized user contacted the Radiation Safety Officer (RSO) and Nassau Police immediately and the case was initiated by Nassau [Police] to track this vehicle. The RSO contacted NYSDOH BERP the following morning to report the missing device.
"The following information is available on this device: Make/Model: Troxler 3430 Source 1: Cs-137 (10 millicurie); Source 2: Americium-241:Be (40 millicurie); Device S/N: 20136.
"New York State Department of Health is reaching out to the manufacturer and neighboring regulators to inform them of this event. NYSDOH will continue to monitor this event and provide updates as necessary.
"NY Event Report ID: NYDOH-22-07"
* * * UPDATE ON 11/21/2022 AT 1549 EST FROM DANIEL SAMSON TO IAN HOWARD * * *
The following information was provided by the NYSDOH BERP via fax:
"On November 21, 2022, the licensee notified the NYSDOH BERP that the above mentioned vehicle and device were located by local law enforcement agencies and returned to the licensee. The licensee confirmed that there was no apparent tampering of the device and carrying case, however, the licensee is performing a leak test to confirm sources have not been breached during this incident prior to recommissioning this device into service.
"The licensee is providing a written description of this event including a failure analysis and proposed corrective actions. As a result, NYSDOH will continue to monitor this event and provide updates as necessary. This event is still open as of 11/21/2022."
Notified R1DO (Carfang) and NMSS Events Notification, ILTAB, and CNSC email groups.
* * * UPDATE ON 12/08/2022 AT 1613 EST FROM DANIEL SAMSON TO LLOYD DESOTELL * * *
The following information was provided by the NYSDOH BERP via fax:
"The licensee provided a written report [to NYSDOH] in accordance with 10 CFR 20.2201(b). This report further confirmed the events as previously described, and provided a copy of the police report filed by Nassau County Police Department. In discussion with the licensee, it was proposed that staff are re-trained in security and notification procedures as a preventative measure. The Radiation Safety Officer has purchased Apple AirTags for installation into the device case as an additional tool to rapidly track and locate any missing/stolen gauges in the future as a supplemental mitigation action.
"New York State Department of Health has independently evaluated the investigation, failure analysis, and corrective actions provided by the licensee and has deemed the response and subsequent actions sufficient. NYSDOH has closed this event."
Notified R1DO (Bickett) and NMSS Events Notification, ILTAB, and CNSC email groups.
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
EN Revision Text: AGREEMENT STATE REPORT - STOLEN MOISTURE DENSITY GAUGE
The following information was provided by the New York State Department of Health Bureau of Environmental Radiation Protection (NYSDOH BERP) via fax:
"On November 3, 2022, at approximately 1430 EDT, an authorized user for the licensee had finished conducting soils testing at a temporary job site located in Manhasset, NY and locked the moisture density device in the carrying case within the trunk of their vehicle. The authorized user was conducting concrete work while the gauge was locked in the trunk and returned to their vehicle later to find that the vehicle was stolen, with the gauge locked in the trunk. The authorized user contacted the Radiation Safety Officer (RSO) and Nassau Police immediately and the case was initiated by Nassau [Police] to track this vehicle. The RSO contacted NYSDOH BERP the following morning to report the missing device.
"The following information is available on this device: Make/Model: Troxler 3430 Source 1: Cs-137 (10 millicurie); Source 2: Americium-241:Be (40 millicurie); Device S/N: 20136.
"New York State Department of Health is reaching out to the manufacturer and neighboring regulators to inform them of this event. NYSDOH will continue to monitor this event and provide updates as necessary.
"NY Event Report ID: NYDOH-22-07"
* * * UPDATE ON 11/21/2022 AT 1549 EST FROM DANIEL SAMSON TO IAN HOWARD * * *
The following information was provided by the NYSDOH BERP via fax:
"On November 21, 2022, the licensee notified the NYSDOH BERP that the above mentioned vehicle and device were located by local law enforcement agencies and returned to the licensee. The licensee confirmed that there was no apparent tampering of the device and carrying case, however, the licensee is performing a leak test to confirm sources have not been breached during this incident prior to recommissioning this device into service.
"The licensee is providing a written description of this event including a failure analysis and proposed corrective actions. As a result, NYSDOH will continue to monitor this event and provide updates as necessary. This event is still open as of 11/21/2022."
Notified R1DO (Carfang) and NMSS Events Notification, ILTAB, and CNSC email groups.
* * * UPDATE ON 12/08/2022 AT 1613 EST FROM DANIEL SAMSON TO LLOYD DESOTELL * * *
The following information was provided by the NYSDOH BERP via fax:
"The licensee provided a written report [to NYSDOH] in accordance with 10 CFR 20.2201(b). This report further confirmed the events as previously described, and provided a copy of the police report filed by Nassau County Police Department. In discussion with the licensee, it was proposed that staff are re-trained in security and notification procedures as a preventative measure. The Radiation Safety Officer has purchased Apple AirTags for installation into the device case as an additional tool to rapidly track and locate any missing/stolen gauges in the future as a supplemental mitigation action.
"New York State Department of Health has independently evaluated the investigation, failure analysis, and corrective actions provided by the licensee and has deemed the response and subsequent actions sufficient. NYSDOH has closed this event."
Notified R1DO (Bickett) and NMSS Events Notification, ILTAB, and CNSC email groups.
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 56254
Rep Org: NC Div of Radiation Protection
Licensee: Duke University Medical Center
Region: 1
City: Durham State: NC
County:
License #: 032-0247-4
Agreement: Y
Docket:
NRC Notified By: Ken Bugaj Jr.
HQ OPS Officer: Bill Gott
Licensee: Duke University Medical Center
Region: 1
City: Durham State: NC
County:
License #: 032-0247-4
Agreement: Y
Docket:
NRC Notified By: Ken Bugaj Jr.
HQ OPS Officer: Bill Gott
Notification Date: 12/02/2022
Notification Time: 14:41 [ET]
Event Date: 12/01/2022
Event Time: 00:00 [EST]
Last Update Date: 12/02/2022
Notification Time: 14:41 [ET]
Event Date: 12/01/2022
Event Time: 00:00 [EST]
Last Update Date: 12/02/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Cahill, Christopher (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Cahill, Christopher (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - PATIENT UNDERDOSE
The following information was provided by the North Carolina Division of Radiation Protection via email:
"The state of North Carolina Radioactive Materials Branch received a report at 1050 EST on December 2, 2022, from Duke University Medical Center (license number: 032-0247-4) of a possible medical event involving a patient receiving Yttrium-90 therapy for treatment of a liver tumor. The treatment had an intended dosage of 91.6 mCi with a delivered dosage of 54.6 mCi resulting in a 40 percent under dosing that did not appear to involve stasis. The patient and the patient's representative were notified at the time of the treatment and the referring physician was notified the morning of December 2, 2022. The licensee is currently investigating the root cause but initially believes it to be caused by equipment failure. The State is currently investigating and will provide more information as it becomes available."
NC Incident No.: NC220015
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
The following information was provided by the North Carolina Division of Radiation Protection via email:
"The state of North Carolina Radioactive Materials Branch received a report at 1050 EST on December 2, 2022, from Duke University Medical Center (license number: 032-0247-4) of a possible medical event involving a patient receiving Yttrium-90 therapy for treatment of a liver tumor. The treatment had an intended dosage of 91.6 mCi with a delivered dosage of 54.6 mCi resulting in a 40 percent under dosing that did not appear to involve stasis. The patient and the patient's representative were notified at the time of the treatment and the referring physician was notified the morning of December 2, 2022. The licensee is currently investigating the root cause but initially believes it to be caused by equipment failure. The State is currently investigating and will provide more information as it becomes available."
NC Incident No.: NC220015
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
Agreement State
Event Number: 56255
Rep Org: Georgia Radioactive Material Pgm
Licensee: Construction Materials Services
Region: 1
City: Locust Grove State: GA
County:
License #: GA 1392-1
Agreement: Y
Docket:
NRC Notified By: Shatavia Grimes
HQ OPS Officer: Bill Gott
Licensee: Construction Materials Services
Region: 1
City: Locust Grove State: GA
County:
License #: GA 1392-1
Agreement: Y
Docket:
NRC Notified By: Shatavia Grimes
HQ OPS Officer: Bill Gott
Notification Date: 12/02/2022
Notification Time: 14:51 [ET]
Event Date: 12/02/2022
Event Time: 00:00 [EST]
Last Update Date: 12/02/2022
Notification Time: 14:51 [ET]
Event Date: 12/02/2022
Event Time: 00:00 [EST]
Last Update Date: 12/02/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Cahill, Christopher (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB (EMAIL)
Cahill, Christopher (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB (EMAIL)
AGREEMENT STATE REPORT - LOST GAUGE
The following information was provided by the Georgia Radioactive Material Program via email:
"[The] gauge was placed on the tailgate of a truck by a technician at the Eastman Airport and not secured in the box. It fell out within 4 miles of last use in the city limits of Eastman, Dodge County. The licensee will be contacted for more detailed information. The Georgia Radioactive Material Program will update this report as more information comes in. "
Georgia Incident No.: 62
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following information was provided by the Georgia Radioactive Material Program via email:
"[The] gauge was placed on the tailgate of a truck by a technician at the Eastman Airport and not secured in the box. It fell out within 4 miles of last use in the city limits of Eastman, Dodge County. The licensee will be contacted for more detailed information. The Georgia Radioactive Material Program will update this report as more information comes in. "
Georgia Incident No.: 62
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Power Reactor
Event Number: 56264
Facility: Turkey Point
Region: 2 State: FL
Unit: [3] [] []
RX Type: [3] W-3-LP,[4] W-3-LP
NRC Notified By: Szemei Choi
HQ OPS Officer: Thomas Herrity
Region: 2 State: FL
Unit: [3] [] []
RX Type: [3] W-3-LP,[4] W-3-LP
NRC Notified By: Szemei Choi
HQ OPS Officer: Thomas Herrity
Notification Date: 12/08/2022
Notification Time: 14:39 [ET]
Event Date: 12/08/2022
Event Time: 14:02 [EST]
Last Update Date: 12/08/2022
Notification Time: 14:39 [ET]
Event Date: 12/08/2022
Event Time: 14:02 [EST]
Last Update Date: 12/08/2022
Emergency Class: Unusual Event
10 CFR Section:
50.72(a) (1) (i) - Emergency Declared
10 CFR Section:
50.72(a) (1) (i) - Emergency Declared
Person (Organization):
Miller, Mark (R2DO)
Miller, Chris (NRR EO)
Crouch, Howard (IR)
Dudes, Laura (R2RA)
Andrea Veil (NRR)
Miller, Mark (R2DO)
Miller, Chris (NRR EO)
Crouch, Howard (IR)
Dudes, Laura (R2RA)
Andrea Veil (NRR)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 3 | N | Y | 100 | Power Operation | 100 | Power Operation |
EN Revision Imported Date: 12/9/2022
EN Revision Text: UNUSUAL EVENT DUE TO EXCESSIVE REACTOR COOLANT SYSTEM LEAKAGE
At 1402 EST Turkey Point Unit 3, while operating at 100 percent, declared an Unusual Event due to unidentified leakage greater than 10 gallons per minute for more than 15 minutes. The abnormal procedure for Reactor Coolant System leakage was entered. The plant remains at 100 percent power. The cause of the leakage is under investigation.
At 1446 EST it was verified that the leak had been isolated. The plant remains at 100 percent power.
Unit 4 was unaffected.
State and local authorities were notified by the licensee.
The NRC Resident Inspector has been notified.
Notified DHS SWO, FEMA Operations Center, CISA Central, FEMA NWC (email), DHS NRCC THD Dest (email), and DHS Nuclear SSA (email).
* * * UPDATE ON 12/08/22 AT 1621 (EST) FROM SZEMEI CHOI TO THOMAS HERRITY * * *
Turkey Point Unit 3 has isolated the leak. The Unusual Event was terminated at 1558 EST.
The NRC Resident Inspector has been notified.
Notified R2DO (Miller), NRR EO (Miller), and IR MOC (Crouch). Notified DHS SWO, FEMA Operations Center, CISA Central, FEMA NWC (email), DHS NRCC THD Dest (email), and DHS Nuclear SSA (email).
EN Revision Text: UNUSUAL EVENT DUE TO EXCESSIVE REACTOR COOLANT SYSTEM LEAKAGE
At 1402 EST Turkey Point Unit 3, while operating at 100 percent, declared an Unusual Event due to unidentified leakage greater than 10 gallons per minute for more than 15 minutes. The abnormal procedure for Reactor Coolant System leakage was entered. The plant remains at 100 percent power. The cause of the leakage is under investigation.
At 1446 EST it was verified that the leak had been isolated. The plant remains at 100 percent power.
Unit 4 was unaffected.
State and local authorities were notified by the licensee.
The NRC Resident Inspector has been notified.
Notified DHS SWO, FEMA Operations Center, CISA Central, FEMA NWC (email), DHS NRCC THD Dest (email), and DHS Nuclear SSA (email).
* * * UPDATE ON 12/08/22 AT 1621 (EST) FROM SZEMEI CHOI TO THOMAS HERRITY * * *
Turkey Point Unit 3 has isolated the leak. The Unusual Event was terminated at 1558 EST.
The NRC Resident Inspector has been notified.
Notified R2DO (Miller), NRR EO (Miller), and IR MOC (Crouch). Notified DHS SWO, FEMA Operations Center, CISA Central, FEMA NWC (email), DHS NRCC THD Dest (email), and DHS Nuclear SSA (email).