Event Notification Report for November 12, 2022

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
11/11/2022 - 11/12/2022

EVENT NUMBERS
56220
Power Reactor
Event Number: 56220
Facility: Cooper
Region: 4     State: NE
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: Scott Johnson
HQ OPS Officer: Lloyd Desotell
Notification Date: 11/13/2022
Notification Time: 04:01 [ET]
Event Date: 11/12/2022
Event Time: 23:19 [CDT]
Last Update Date: 11/13/2022
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical 50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
Person (Organization):
Azua, Ray (R4DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 A/R Y 2 Startup 0 Hot Standby
Event Text
AUTOMATIC REACTOR SCRAM

The following information was provided by the licensee email:

"On November 12, 2022, at 2319 CST, an actuation of the reactor protection system (RPS) initiated a full scram. The plant was in Mode 2, reactor pressure was 149 pounds. The high pressure coolant injection (HPCI) injection valve, HPCI-MOV-MO19, opened and injected cold water into the reactor vessel while HPCI system testing was in progress. The cause is still under investigation. All control rods inserted. Plant is currently in Mode 3 and stable. All systems operated as designed with no Primary Containment Isolation System group isolations. This event is being reported under two event classifications:

"50. 72(b)(2)(iv)(B) -- "Any event or condition that results in actuation of the reactor protection system (RPS) when the reactor is critical except when the actuation results from and is part of a pre-planned sequence during testing or reactor operation."

"50. 72(b)(3)(iv)(A) -- "Any event or condition that results in valid actuation of any of the systems listed in paragraph (b)(3)(iv)(B) of this section except when the actuation results from and is part of a pre-planned sequence during testing or reactor operation."

"The NRC Resident has been informed."