Skip to main content

Event Notification Report for November 08, 2022

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
11/07/2022 - 11/08/2022

Agreement State
Event Number: 56191
Rep Org: SC Dept of Health & Env Control
Licensee: Santee Cooper - Cross Generating Station
Region: 1
City: Pineville   State: SC
County:
License #: 335
Agreement: Y
Docket:
NRC Notified By: Adam Gause
HQ OPS Officer: Thomas Herrity
Notification Date: 10/31/2022
Notification Time: 14:24 [ET]
Event Date: 10/31/2022
Event Time: 00:00 [EDT]
Last Update Date: 10/31/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Lilliendahl, Jon (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - STUCK SHUTTERS

The following was received from the state of South Carolina via email:

"The South Carolina Department of Health and Environmental Control was notified via telephone on 10/31/22 that three fixed gauging device shutters were stuck in the closed position. All three fixed gauging devices are Thermo Fisher Scientific Model 5197 gauging devices, serial numbers B7842, B7847, and B7841. The activity of each gauging device is 100 mCi of Cs-137. The licensee is reporting that all three fixed gauging devices are mounted 12-15 feet above accessible areas. No elevated exposure rates are being reported. Department inspectors will be dispatched to the facility. This event is still under investigation by the South Carolina Department of Health and Environmental Control."

South Carolina Event Number: To be assigned.


Agreement State
Event Number: 56193
Rep Org: WA Office of Radiation Protection
Licensee: University of Washington
Region: 4
City: Seattle   State: WA
County:
License #: WN-C001-1
Agreement: Y
Docket:
NRC Notified By: Raj Maharjan
HQ OPS Officer: Ernest West
Notification Date: 10/31/2022
Notification Time: 17:10 [ET]
Event Date: 10/25/2022
Event Time: 00:00 [PDT]
Last Update Date: 10/31/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Agrawal, Ami (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - LEAKING SEALED SOURCE

The following information was provided by the Washington State Department of Health via email:

"On 10/31/2022, a licensee, University of Washington - License Number: C001-1, reported that a 12.4 mCi Ni-63 source was leaking. The source was part of a Hewlett Packard electron capture detector (ECD) (Hewlett Packard, Model# G1223A, Source Serial # F5941). A pre-disposal wipe test of the ECD contained in a gas chromatograph (Hewlett Packard Model#5890) was performed on 10/25/22 after receiving the gas chromatograph from its owner for disposal. On 10/25/2022, the wipe test results indicated that the ECD had more than 0.005 microcuries of removable contamination. This device will be sent to NRD Static Control, LLC for recycling/disposal."

WA incident event number: WA-22-020


Agreement State
Event Number: 56195
Rep Org: Colorado Dept of Health
Licensee: Geostruct Engineers, Inc. dba RMG-Rocky Mountain Group
Region: 4
City: Englewood   State: CO
County:
License #: CO 758-01
Agreement: Y
Docket:
NRC Notified By: Tim Thorvaldson
HQ OPS Officer: Donald Norwood
Notification Date: 11/01/2022
Notification Time: 14:05 [ET]
Event Date: 10/31/2022
Event Time: 16:00 [MDT]
Last Update Date: 11/01/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Agrawal, Ami (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - FOUND MOISTURE DENSITY GAUGE

The following information was received via email from the Colorado Department of Public Health and Environment (the Department):

"During the afternoon of 10/31/22, an InstroTek model 3500 portable gauge was found by a member of the public and turned into Radiation Pros, LLC (specific license CO 1183-01). The isotopes are presumed to be 11 mCi cesium-137 and 44 mCi americium-241:beryllium, but the Department is awaiting confirmation. Radiation Pros, LLC contacted the Department to let us know that they have the InstroTek model 3500 on site and that they contacted InstroTek with the serial number of the portable gauge to find out who owned the gauge. InstroTek let Radiation Pros know that the gauge belongs to Geostruct Engineers, Inc. dba RMG-Rocky Mountain Group, radioactive material license number CO 758-01. Radiation Pros contacted Geostruct Engineers and let them know that they have the portable gauge. Geostruct Engineers picked up the InstroTek portable gauge and transported it back to the licensed location. This event appears to be unrelated to Colorado event CO210032 [EN 55510]."

Colorado Event Report ID No.: CO 220036

THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Non-Agreement State
Event Number: 56212
Rep Org: Engineering & Inspections, Hawaii
Licensee: Engineering & Inspections, Hawaii
Region: 4
City: Kapolei   State: HI
County:
License #: 53-277-31-01
Agreement: N
Docket:
NRC Notified By: Ken McNamara
HQ OPS Officer: Karen Cotton-Gross
Notification Date: 11/06/2022
Notification Time: 14:30 [ET]
Event Date: 11/05/2022
Event Time: 22:30 [HST]
Last Update Date: 11/06/2022
Emergency Class: Non Emergency
10 CFR Section:
30.50(b)(2) - Safety Equipment Failure
Person (Organization):
Agrawal, Ami (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
NON-AGREEMENT STATE REPORT - UNABLE TO RETRACT RADIOGRAPHY CAMERA SOURCE

The following information was provided by the licensee via phone:

On November 5, 2022 at 2230 HST, Engineering & Inspections, Hawaii was performing radiography operations at a refinery using a QSA 880 Series Delta camera (Industrial Nuclear Model 7 source containing 84 Ci of Ir-192) when the source became stuck. Attempts to retrieve the source resulted in breaking the drive cable. The source remains in the guide tube. The licensee placed lead shielding around the source and is continuously monitoring the area. No overexposures were reported.

The licensee is attempting to contact Industrial Nuclear Corporation and QSA Global for assistance in retrieving the source.


Fuel Cycle Facility
Event Number: 56199
Facility: Westinghouse Electric Corporation
Region: 2     State: SC
Unit: [] [] []
RX Type: Uranium Fuel Fabrication
NRC Notified By: Patrick Donnelly
HQ OPS Officer: Eric Simpson
Notification Date: 11/02/2022
Notification Time: 11:12 [ET]
Event Date: 11/01/2022
Event Time: 11:29 [EDT]
Last Update Date: 11/02/2022
Emergency Class: Non Emergency
10 CFR Section:
PART 70 APP A (b)(1) - Unanalyzed Condition
Person (Organization):
Miller, Mark (R2DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
UNANALYZED CONDITION - NUCLEAR MATERIAL RECEIVED IN EXCESS OF LICENSE LIMITS

The following is a synopsis of information provided by the licensee via email:

Uranium Recovery and Recycle Services (URRS) personnel were offloading ash on 11/1/22 that they had received in 2003 from the decommissioned Hematite site at Dock 3. The operators opened the Type A drum and from an inner canister pulled out the bag of Hematite ash. The bag had a tag indicating enrichment levels in excess of their license limits. Upon discovery, the operators contacted criticality safety engineering and the safeguards coordinator. The operators were instructed to replace the bag in the canister and drum and to segregate the drums that contained material potentially greater than license limits in accordance with generally accepted guidance for criticality safety. An extent of condition was performed using materials control and accounting records of the received material. It was discovered that several drums potentially contain material in excess of license enrichment limits. The plant is in a safe condition and the steps taken in response to this event are considered to be conservative.

This report is being made per 10 CFR 70 Appendix A (b)(1). This event resulted in the facility being in a state that was not analyzed in their Integrated Safety Analysis Report and resulted in a failure to meet the performance requirements of 10 CFR 70.61, specifically there were no controls in place due to it being an unanalyzed condition. Westinghouse is unable to open, sample, and test the ash to determine enrichment until the proposed process has been analyzed with documented controls in place.

This issue has been entered into the licensee's corrective action program as IR-2022-9728.


Agreement State
Event Number: 56201
Rep Org: WA Office of Radiation Protection
Licensee: IsoRay Medical
Region: 4
City: Richland   State: WA
County:
License #: WN-L0213-1
Agreement: Y
Docket:
NRC Notified By: Raj Maharjan
HQ OPS Officer: Donald Norwood
Notification Date: 11/02/2022
Notification Time: 15:58 [ET]
Event Date: 09/29/2022
Event Time: 00:00 [PDT]
Last Update Date: 11/02/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Agrawal, Ami (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - LEAKING CS-131 BRACHYTHERAPY SOURCE

The following information was received via email from the Washington Office of Radiation Protection:

"On 11/2/2022, a licensee, IsoRay Medical - License Number: WN-L0213-1 reported a Cs-131 Brachytherapy source, model CS-1, leaking at customer's facility. A customer detected contamination on equipment used during a procedure with Cs-131 seeds. The customer was not initially able to identify the isotope of the contamination using their equipment, however they were able to perform a half-life estimation using dose measurements on a collimated container loaded with all the contaminated items from the procedure. The decay rate was roughly in line with Cs-131. The customer indicated that as part of their own procedures, the order, which arrived as a non-sterile mick pig, was opened and surveyed. No contamination was found at that time. A thorough investigation is ongoing."

Washington Incident Number: WA-22-021