Event Notification Report for October 13, 2022

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
10/12/2022 - 10/13/2022

EVENT NUMBERS
5616156269
Fuel Cycle Facility
Event Number: 56161
Facility: Honeywell International, Inc.
Region: 2     State: IL
Unit: [] [] []
RX Type: Uranium Hexafluoride Production
Comments: Uf6 Conversion (Dry Process)


NRC Notified By: Sean Patterson
HQ OPS Officer: Kerby Scales
Notification Date: 10/13/2022
Notification Time: 19:12 [ET]
Event Date: 10/13/2022
Event Time: 17:25 [CDT]
Last Update Date: 10/13/2022
Emergency Class: Alert
10 CFR Section:
40.35(f) - Emergency Declared
Person (Organization):
Miller, Mark (R2DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Lubinksi, John (NMSS)
Dudes, Laura (R2RA)
Whited, Jeffrey (IR)
Event Text
ALERT DECLARED DUE TO A FIRE IN LABORATORY BUILDING UNDER RENOVATION

On 10/13/2022 at 1725 CDT, the licensee declared an Alert due to a fire in a laboratory building under renovation. The licensee contacted local Fire and Emergency Medical Service who responded and extinguished the fire. There was no offsite release of radiological material.

The licensee notified local authorities and the Illinois Emergency Management Agency of the event.

* * * UPDATE ON 10/13/22 AT 1851 CDT FROM SEAN PATTERSON TO KERBY SCALES * * *

At 1851 CDT, the licensee terminated the Alert and reported the fire was out.

Notified DHS SWO, FEMA Ops Center, USDA Ops Center, HHS Ops Center, DOE Ops Center, CISA Central Watch Officer, EPA EOC, R2DO (Miller), IRMOC (Whited), Director DFM (Helton).


Power Reactor
Event Number: 56269
Facility: Wolf Creek
Region: 4     State: KS
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: Jason Knust
HQ OPS Officer: Brian Lin
Notification Date: 12/12/2022
Notification Time: 11:05 [ET]
Event Date: 10/13/2022
Event Time: 16:48 [CST]
Last Update Date: 12/12/2022
Emergency Class: Non Emergency
10 CFR Section:
21.21(d)(3)(i) - Defects And Noncompliance
Person (Organization):
Drake, James (R4DO)
Part 21/50.55 Reactors, - (EMAIL)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Defueled 100 Power Operation
Event Text
PART 21 - INADEQUATE TORQUE VALUES

The following information was provided by the licensee via email:

"On October 13, 2022, during Refueling Outage 25, 2 bolts and 2 washers were discovered in the strainer basket upstream of the main steam stop valve in the steam line from the 'A' steam generator. It was determined that these bolts and washers were from the main steam isolation valve (MSIV) upstream of the stop valve. One bolt and one washer were also determined to be missing from the MSIV on the line from the 'B' steam generator. The MSIVs are a similar design as the Main Feedwater Isolation Valves (MFIVs). It appears that the torque values for these backseat bolts provided by the vendor weren't sufficient to prevent the bolts from coming loose. Wolf Creek Nuclear Operating Corporation personnel evaluated the condition and determined that the inadequate torque values provided by the vendor could have constituted a substantial safety hazard if left uncorrected. In particular, if bolts had come loose from the MFIVs, they could have traveled downstream to the steam generators and then challenged the integrity of steam generator tubes.

"The NRC Senior Resident Inspector has been notified.

"This is a non-emergency notification required by 10 CFR 21.21(d)(3)(i).

"A written notification will be provided within 30 days."